1.A study of insertion depth of buchanan plugger after shaping using NI-TI rotary files in simulated resin root canals.
Youn Sik PARK ; Dong Jun KIM ; Yun Chan HWANG ; In Nam HWANG ; Won Mann OH
Journal of Korean Academy of Conservative Dentistry 2006;31(2):125-132
This study was conducted to evaluate the insertion depth of Buchanan plugger after shaping by various Ni-Ti rotary files. It was conducted to determine which size of plugger are appropriate, when root canals are shaped with Ni-Ti rotary files and obturated by Continuous wave of condensation technique. Two type of eighty simulated resin blocks were used : J-shaped and straight shaped canal. The simulated canals were instrumented by ProTaper and ProFile. Buchanan pluggers were inserted into the canal, and then the image was recorded to scanner. The distance from the apex of the canal to the plugger tip was measured by image analysis program. Data were analyzed by one-way ANOVA followed by Scheffe's test. The results were as follows 1. In straight canal finished up to ProTaper F2 and F3 file, F and FM pluggers were inserted more than 5 mm short of working length. 2. In J-shaped canal finished up to ProTaper F2 file, F pluggers were inserted more than 5 mm short of working length. Finished up to ProTaper F3 file, F and FM pluggers were inserted more than 5 mm short of working length. 3. In straight and J-shaped canal finished up to ProFile .06/#20 and .06/#25, any of Buchanan plugger could not be inserted more than 5 mm short of working length. These results suggest that canals shaped by ProTaper could be obturated by Continuous wave of condensation technique with F and FM size Buchanan plugger.
Dental Pulp Cavity*
2.The instrument-centering ability of four Nickel-Titanium instruments in simulated curved root canals.
Jae Hoon KU ; Hoon Sang CHANG ; Seok Woo CHANG ; Hwan Hee CHO ; Ji Myung BAE ; Kyung San MIN
Journal of Korean Academy of Conservative Dentistry 2006;31(2):113-118
The aim of this study was to evaluate the ability of newly marketed NRT instruments to maintain the original root canal configuration and curvature during preparation in comparison with the three existing instruments in simulated root canals. Simulated canals in resin blocks were prepared with ProFile, K3, ProTaper, and NRT instrument (n = 10 canals in each case). Pre- and post-operative images were recorded, and assessment of canal shape was completed with a computer image analysis program. The data were analyzed statistically using the One-way ANOVA followed by Duncan's test. The ability of instruments to remain centered in prepared canals at 1-, 2-mm levels was significantly better in ProFile groups than in other groups (p < 0.05). The change of centering ratio in NRT groups at 5-mm level was significantly greater than ProFile group and at 6- and 7-mm level than all other groups (p < 0.05). Although the NRT system was comparable to other systems in regards to its ability to maintain the canal configuration of apical portion, this system was more influenced by the mid-root curvature due to its stainless-steel files for coronal preflaring.
Dental Pulp Cavity*
3.Evaluation of the cytotoxicity of calcium phosphate root canal sealers.
Jee Hyun LEE ; Seung Ho BAEK ; Kwang Shik BAE
Journal of Korean Academy of Conservative Dentistry 2003;28(4):295-302
No abstract available.
Calcium*
;
Dental Pulp Cavity*
4.Regional bond strength of dentin bonding systems to pulp chamber dentin.
Sang Hyuk LEE ; Gi Woon CHOI ; Kyoung Kyu CHOI
Journal of Korean Academy of Conservative Dentistry 2004;29(1):13-22
No abstract available.
Dental Pulp Cavity*
;
Dentin*
5.In vitro comparison of measurement accuracy in pre-enlarged and enlarged canals with four apex locators.
Sang Yup SUNG ; Jeong Kil PARK ; Bock HUR ; Hyeon Cheol KIM
Journal of Korean Academy of Conservative Dentistry 2006;31(5):371-377
The purposes of this study were to assess the accuracy of measurements in pre-enlarged canals with small instruments and to compare the accuracies, in enlarged canal, with small size instruments and instruments that match the actual canal diameter using Root ZX, Bingo1020, SmarPex, and e-Magic Finder. Ten extracted teeth were embedded in an alginate model made for testing apex locators. A size 10 file was placed into the root canal until the tip of the file reached the plane of the major diameter of the foramen under a dental operating microscope at the 25 x magnification. The measurement was done with digital caliper and defined as actual length. Electronic length measurement with a size 10 file in pre-enlarged canal was done by reading the index indicating Apex of each device to gain a definite value. After completion of canal enlargement to a size 45 file, each difference between actual length and electric measurement value with a size 10 and 40 files in enlarged canal was recorded as L10 and L40. The one-way ANOVA and Scheffe's multiple range tests were computed for analyze the differences among the four apex locators in the same group. The Student's t-test between L10 and L40 of each locator was done. The accuracies of electronic measurements were significantly different among the 4 devices. The file size made no difference on the accuracy of electronic measurement in enlarged canal with same device. The e-Magic Finder was the most accurate device among the 4 apex locators used in this study.
Dental Pulp Cavity
;
Tooth
6.A comparison of shaping ability of the three ProTaper(R) instrumentation techniques in simulated canals.
So Youn KIM ; Jeong Kil PARK ; Bock HUR ; Hyeon Cheol KIM
Journal of Korean Academy of Conservative Dentistry 2005;30(1):58-65
The purpose of this study was to compare the shaping ability of the three ProTaper(R) instrumentation techniques in simulated canals. Thirty resin blocks were divided into 3 groups with 10 canals each. Each group was instrumented with manual ProTaper(R) (Group M), rotary ProTaper(R) (Group R), and hybrid technique (Group H). Canal preparation time was recorded. The images of pre- and post-instrumented root canals were scanned and superimposed. The amounts of canal deviation, total canal width, inner canal width, outer canal width and centering ratio were measured at apical 1, 2, 3, 4, 5 and 6 mm levels. 1. Canal preparation time was the shortest in R group (p < 0.05). 2. The amounts of total canal width in R group was generally larger than the other groups, but no significant differences were observed except at the 1, 3 mm levels (p > 0.05). 3. The amounts of inner canal width in R group was larger than M group at the 1 mm level and H group was larger than R group at the 6 mm level (p < 0.05). The amounts of outer canal width in R group was larger than H group only at the 1 mm level (p < 0.05). 4. The direction of canal deviation in H, R group at the 1, 2, 3 mm levels was outward and that in M group at the 1, 2 mm levels was inward. The amounts of canal deviation in H group was larger than R group at the 6 mm level (p < 0.05). 5. The amounts of centering ratio in H group was larger than R group at the 6 mm level (p < 0.05).
Dental Pulp Cavity
7.In-depth morphological study of mesiobuccal root canal systems in maxillary first molars: review.
Seok Woo CHANG ; Jong Ki LEE ; Yoon LEE ; Kee Yeon KUM
Restorative Dentistry & Endodontics 2013;38(1):2-10
A common failure in endodontic treatment of the permanent maxillary first molars is likely to be caused by an inability to locate, clean, and obturate the second mesiobuccal (MB) canals. Because of the importance of knowledge on these additional canals, there have been numerous studies which investigated the maxillary first molar MB root canal morphology using in vivo and laboratory methods. In this article, the protocols, advantages and disadvantages of various methodologies for in-depth study of maxillary first molar MB root canal morphology were discussed. Furthermore, newly identified configuration types for the establishment of new classification system were suggested based on two image reformatting techniques of micro-computed tomography, which can be useful as a further 'Gold Standard' method for in-depth morphological study of complex root canal systems.
Dental Pulp Cavity
;
Molar
8.Root canal treatment of a mandibular second premolar with three separate root canals.
Seok Ryun LEE ; Seol Hee SHIN ; Sung Ok HONG ; Chang Kyu SONG ; Hoon Sang CHANG ; Kyung San MIN
Journal of Korean Academy of Conservative Dentistry 2010;35(4):302-305
Mandibular premolars show a wide variety of root canal anatomy. Especially, the occurrence of three canals with three separate foramina in mandibular second premolars is very rare. This case report describes the root canal treatment of an unusual morphological configuration of the root canal system and supplements previous reports of the existence of such configuration in mandibular second premolar.
Bicuspid
;
Dental Pulp Cavity
9.Antimicrobial activity of eight root canal sealers before and after setting.
Denny Y FANG ; Woocheol LEE ; Chern H LAI
Journal of Korean Academy of Conservative Dentistry 2002;27(2):207-211
No abstract available.
Dental Pulp Cavity
10.In vivo study on the biocompatibility of new resin-based root canal sealers.
Yong Beom KIM ; Seung Ho BAEK ; Kwang Shik BAE
Journal of Korean Academy of Conservative Dentistry 2002;27(2):122-134
No abstract available.
Dental Pulp Cavity