1.A method of transversal stuff of root canal
Journal of Vietnamese Medicine 1999;233(2):46-0
Many images of X-ray examination showed that the treatment of endodontal disease had a good effect but infact, the root canal was not completely closed, the fluid can permeat in to the root canal leading to the infection. Regardless the arthopady of the root canal and isolation of teeth during fusion, this study applied a method of trans versal stuff of root canal. This method involved the stuff of the patch in to the root canal by stick of gutta or lentulo and then stuff of the main gutta and smaller stick with standard stick in to the end of root canal, at last cutting the spare gutta
Dental Pulp Cavity
;
Dental Pulp Diseases
3.The effect of different flute design and torque-controlled motor on the shaping ability of simulated resin root canals.
Hyoung Mee ROH ; Bock HUH ; Hyeon Cheol KIM ; Jeong Kil PARK
Journal of Korean Academy of Conservative Dentistry 2005;30(6):486-492
The purpose of this study was to compare the shaping ability of the two different Ni-Ti file systems and the two different engine systems in simulated canals. A total of four groups of each 10 were tested. Each group was instrumented with HeroShaper(R)and Endo-Mate2(R) (Group HE), HeroShaper(R) and Tecnika(R) (Group HT), ProFile(R) and Endo-Mate2(R) (Group PE), and ProFile(R) and Tecnika(R) (Group PT). Canal preparation time was recorded. The images of pre- and post- instrumented root canals were scanned and superimposed. The amounts of increased width and centering ratio were measured and calculated at apical 1, 3 and 5 mm levels. These data were statistically analyzed with one-way ANOVA and Duncan's multiple range test The results of this study were as follows; 1. Canal preparation time of HT group was the shortest (p < 0.05). 2. The amount of increased canal width in HE group was significantly larger than PT group at apical 1 mm level (p < 0.05). At apical 3 mm level, PT group was significantly smaller than other groups (p < 0.05). At apical 5 mm level, PE group was significantly larger than PT group (p < 0.05). 3. The amount of centering ratio in HE group was significantly larger than other groups (p < 0.05). At apical 5 mm level, HT group was significantly larger than PE group and PT group (p < 0.05). Under the condition of this study, torque-controlled endodontic motor is safer than no torque controlled motor, especially when the active file is used.
Dental Pulp Cavity*
;
Torque
4.An accuracy of the several electronic apex locators on the mesial root canal of the mandibular molar.
Young Lin CHO ; Wook Hee SON ; Ho Keel HWANG
Journal of Korean Academy of Conservative Dentistry 2005;30(6):477-485
The aim of this study was to compare the length between the mesio-buccal and mesio-lingual canal of the mandibular molars before and after early coronal flaring at the different measuring time using several electronic apex locators. Fifty mandibular molars with complete apical formation and patent foramens were selected. After establishing the initial working length of the buccal and lingual canal of the mesial root using a surgical microscope (Carl Zeiss Co. Germany) at 25X with #15 K-file tip just visible at the foramen, radiographs were taken for the working length. After measuring the length of mesio-buccal and mesio-lingual canal (control group), the electronic lengths were measured at different times using several electronic apex locators (experimental groups; I-Root ZX, II-Bingo, III-Propex, IV-Diagnostic). After early coronal flaring using the K3 file, the additional electronic lengths were measured using the same manner. The results were as follows: One canal has a correct working length for the mesial root of the mandibular molar, it can be used effectively for measuring the electronic working length of another canal when the files are superimposed or encountered at the apex. In addition, the accuracy of the electronic apex locators was increased as the measurement was accomplished after the early coronal flaring of the root canal and the measuring time was repeated.
Dental Pulp Cavity*
;
Molar*
5.A comparison of the shaping ability of four rotary nickel-titanium files in simulated root canals.
Bo Hye KIM ; Kyoung Kyu CHOI ; Sang Hyuk PARK ; Gi Woon CHOI
Journal of Korean Academy of Conservative Dentistry 2010;35(2):88-95
The purpose of this study was to compare the root canal shaping ability of 4 rotary NiTi instruments in simulated root canals. For the preparation of thirty two curved root canals, Mtwo instruments using "single length"technique, and Profile, ProTaper Universal, and K3 using crown-down technique (N = 8) were used. All canal samples were prepared by reaching an apical canal size of #30. Pre- and post-instrumentation digital images were recorded and an assessment of canal shape was determined using a computer image analysis program SigmaScan Pro (Systat Software Inc., San Jose, CA, USA). The changes of the dimension of inner walls of canals, (2) the changes of the dimension of outer walls of canals, and (3) the centering ratio were measured at 7 measuring points, and then data were statistically analyzed using one-way ANOVA and Duncan's test. The results were as below; 1. The root canal shaping ability of Profile was significantly faster than that of other rotary NiTi instruments (p < 0.05). 2. The deformation and fracture of all instruments used for this study were not experienced. 3. In the degree of changes of the dimension of inner walls of canals, Profile demonstrated the lowest changes of the dimension of inner walls of canals except at the measuring points of the 1 and 2 mm (p < 0.05). However, the ProTaper Universal showed the highest changes of the dimension of inner walls of canals at all measuring points (p < 0.05). 4. In the degree of changes of the dimension of outer walls of canals, Mtwo demonstrated the lowest changse of the dimension of outer walls of canals except at the measuring point of the 1 mm (p < 0.05). However, Profile exhibited the highest changes of the dimension of outer walls of canals at the measuring points of 3 and 4 mm and ProTaper Universal and K3 showed the largest changes of the dimension of outer walls of canals at the measuring points of 1, 2, 6, and 7 mm (p < 0.05). 5. In degree of centering ratio, Profile demonstrated the least centering ratio comparing with the centering ratio shown by other NiTi instruments at the measuring points of 1, 4, 5, and 6 mm. Results suggest that in the coronal part of canal preparation, active cutting files such as ProTaper Universal may efficiently flare the canal orifice and form a better taper, and in the apical part of the canal, files which have a better centering ability such as Profile may maintain the original canal curvature and reduce the shaping time.
Collodion
;
Dental Pulp Cavity
6.A comparison of shaping ability of the three ProTaper(R) instrumentation techniques in simulated canals.
So Youn KIM ; Jeong Kil PARK ; Bock HUR ; Hyeon Cheol KIM
Journal of Korean Academy of Conservative Dentistry 2005;30(1):58-65
The purpose of this study was to compare the shaping ability of the three ProTaper(R) instrumentation techniques in simulated canals. Thirty resin blocks were divided into 3 groups with 10 canals each. Each group was instrumented with manual ProTaper(R) (Group M), rotary ProTaper(R) (Group R), and hybrid technique (Group H). Canal preparation time was recorded. The images of pre- and post-instrumented root canals were scanned and superimposed. The amounts of canal deviation, total canal width, inner canal width, outer canal width and centering ratio were measured at apical 1, 2, 3, 4, 5 and 6 mm levels. 1. Canal preparation time was the shortest in R group (p < 0.05). 2. The amounts of total canal width in R group was generally larger than the other groups, but no significant differences were observed except at the 1, 3 mm levels (p > 0.05). 3. The amounts of inner canal width in R group was larger than M group at the 1 mm level and H group was larger than R group at the 6 mm level (p < 0.05). The amounts of outer canal width in R group was larger than H group only at the 1 mm level (p < 0.05). 4. The direction of canal deviation in H, R group at the 1, 2, 3 mm levels was outward and that in M group at the 1, 2 mm levels was inward. The amounts of canal deviation in H group was larger than R group at the 6 mm level (p < 0.05). 5. The amounts of centering ratio in H group was larger than R group at the 6 mm level (p < 0.05).
Dental Pulp Cavity
7.Biocompatibility of root-end filling materials: recent update.
Payal SAXENA ; Saurabh Kumar GUPTA ; Vilas NEWASKAR
Restorative Dentistry & Endodontics 2013;38(3):119-127
The purpose of a root-end filling is to establish a seal between the root canal space and the periradicular tissues. As root-end filling materials come into contact with periradicular tissues, knowledge of the tissue response is crucial. Almost every available dental restorative material has been suggested as the root-end material of choice at a certain point in the past. This literature review on root-end filling materials will evaluate and comparatively analyse the biocompatibility and tissue response to these products, with primary focus on newly introduced materials.
Dental Pulp Cavity
8.In vitro comparison of measurement accuracy in pre-enlarged and enlarged canals with four apex locators.
Sang Yup SUNG ; Jeong Kil PARK ; Bock HUR ; Hyeon Cheol KIM
Journal of Korean Academy of Conservative Dentistry 2006;31(5):371-377
The purposes of this study were to assess the accuracy of measurements in pre-enlarged canals with small instruments and to compare the accuracies, in enlarged canal, with small size instruments and instruments that match the actual canal diameter using Root ZX, Bingo1020, SmarPex, and e-Magic Finder. Ten extracted teeth were embedded in an alginate model made for testing apex locators. A size 10 file was placed into the root canal until the tip of the file reached the plane of the major diameter of the foramen under a dental operating microscope at the 25 x magnification. The measurement was done with digital caliper and defined as actual length. Electronic length measurement with a size 10 file in pre-enlarged canal was done by reading the index indicating Apex of each device to gain a definite value. After completion of canal enlargement to a size 45 file, each difference between actual length and electric measurement value with a size 10 and 40 files in enlarged canal was recorded as L10 and L40. The one-way ANOVA and Scheffe's multiple range tests were computed for analyze the differences among the four apex locators in the same group. The Student's t-test between L10 and L40 of each locator was done. The accuracies of electronic measurements were significantly different among the 4 devices. The file size made no difference on the accuracy of electronic measurement in enlarged canal with same device. The e-Magic Finder was the most accurate device among the 4 apex locators used in this study.
Dental Pulp Cavity
;
Tooth
9.In-depth morphological study of mesiobuccal root canal systems in maxillary first molars: review.
Seok Woo CHANG ; Jong Ki LEE ; Yoon LEE ; Kee Yeon KUM
Restorative Dentistry & Endodontics 2013;38(1):2-10
A common failure in endodontic treatment of the permanent maxillary first molars is likely to be caused by an inability to locate, clean, and obturate the second mesiobuccal (MB) canals. Because of the importance of knowledge on these additional canals, there have been numerous studies which investigated the maxillary first molar MB root canal morphology using in vivo and laboratory methods. In this article, the protocols, advantages and disadvantages of various methodologies for in-depth study of maxillary first molar MB root canal morphology were discussed. Furthermore, newly identified configuration types for the establishment of new classification system were suggested based on two image reformatting techniques of micro-computed tomography, which can be useful as a further 'Gold Standard' method for in-depth morphological study of complex root canal systems.
Dental Pulp Cavity
;
Molar
10.Root canal treatment of a mandibular second premolar with three separate root canals.
Seok Ryun LEE ; Seol Hee SHIN ; Sung Ok HONG ; Chang Kyu SONG ; Hoon Sang CHANG ; Kyung San MIN
Journal of Korean Academy of Conservative Dentistry 2010;35(4):302-305
Mandibular premolars show a wide variety of root canal anatomy. Especially, the occurrence of three canals with three separate foramina in mandibular second premolars is very rare. This case report describes the root canal treatment of an unusual morphological configuration of the root canal system and supplements previous reports of the existence of such configuration in mandibular second premolar.
Bicuspid
;
Dental Pulp Cavity