1.Effect of Helicobacter pylori on apoptosis of SGC-7901 in vitro
Chinese Journal of Pathophysiology 2000;0(12):-
0 05); when concentration of H.pylori ≥1 6?10 8 CFU/L,apoptosis rate increased in a concentration-dependent manner ( P
2.Determination of the Content of Ciprofloxacin Lactate in Eye Drops by Dual-wavelength Spectrophotometry
China Pharmacy 1991;0(01):-
OBJECTIVE:Dual-wavelength spectrophotometry was developed for the determination of ciprofloxacin lactate in its eye drops.METHODS:Detection was performed at wavelength 237nm and 279nm with 0.1mol/L HCl as diluent.RESU_LTS:The assay was linear for ciprofloxacin lactate in the concentration range of 3~9?g/ml,r=0.9 998;The mean recovery was 101.6%,RSD was 2.16%.CONCLUSION:This method is simple,quick,accurate and suitable for the determination of ciprofloxacin lactate in its eye drops.
3.The application of HER2 to pancreatic cancer treatment
Chinese Journal of Hepatobiliary Surgery 2013;19(10):796-800
Pancreatic cancer (PC) is known for its high malignancy and poor prognosis.Furthermore,PC patients have little chance to receive an operation,and chemotherapy is not always an ideal alternative.More effective treatment is necessary because over the last two decades,the morbidity and the mortality of PC has risen continuously.Some new PC treatments involve HER2,a transmembrane protein that has oncological significance.The amplification of its gene or over expression of itself can cause malignant proliferation,suppression of apoptosis,and angiogenesis in PC.Its potential can be seen with HER2 targeted medicines including the clinically used Trastuzumab,but also with bispecific antibody,tyrosine kinase inhibitors,and more.This article will review the application of these new developments.
4.Design of Electrocardiosignal Filter
Chinese Medical Equipment Journal 1989;0(04):-
Objective There are many interferences such as power interference, electrode polarization interference, myoelectricity interference, baseline drift, apparatus buzz and so on in electrocardiosignal acquisition system. It is very difficult to effectively remove these interferences in the process of actual measurement. Methods Power harmonic interference, electrode polarization interference and myoelectricity interference were removed by low-pass filter. Baseline drift was removed by high-pass filter. Power basic frequency interference was removed by 50 Hz trap filter. Results These three design proposals had such advantages as good effect, rapid speed and easy realization. Conclusion They can be well applied in ECG monitor with embedded CPU and real time character. Besides, they can also be used in medical apparatus measuring other biological electric signals and industrial observation and control system.
5.Effects of epidural block combined with general anesthesia on stress response during cardiopulmonary bypass
Chengxiang YANG ; Shuozeng DENG
Chinese Journal of Anesthesiology 1995;0(10):-
Effects of epidural block on stress response during eardiopulmonary bypass were studied. Twenty patients, undergoing open heart surgery with cardiopulmonary bypass, were randomly divided into two groups:the control group with intravenous high-dose fentanyl and enflurane inhalation (1%-1.5%);the tested group with epidural block and enflurane inhalation (0.5%-1%). The plasma norepinephine (NE) and epinephrine (E) concentrations were higher in group control than those in tested group during and after CPB,even at the end of operation (P
6.Determination of Lysophosphatidic Acid by an Enzymatic Cycling Method
Journal of Chinese Physician 2001;0(09):-
Objective To establish a method of testing lysophosphatidic acid (LPA) by enzymatic cycling. Methods The detection system was developed on the principle of enzymatic cycling method and characteristic of LPA. The methodology was evaluated and the content of LPA was tested in 20 samples of plasma with ovarian carcinoma. Results The linearity was 18.6?mol/L and the detection limit was 0.03?mol/L. The within-run and between-run coefficient of variations were 5.3% and 7.4%, respectively. The recovery was 100.7% and there was a significant correlation with the liquid chromatography method(Y=0.953X+0.51). The reagent system was stable and different concentrations of bilirubin, hemoglobin, triglyceride, glucose, urea and ascorbate did not affect the measurement for the assay. The content of LPA in 20 samples of plasma with ovarian carcinoma was significantly higher than that in control group (P
7.Literature Analysis on Adverse Reactions Induced by Interferon
China Pharmacy 2007;0(32):-
OBJECTIVE:To investigate the general patterns and characteristics of the adverse drug reactions(ADR) induced by interferon and to provide guidance for its rational use in the clinic.METHODS:A total of 64 ADR cases induced by interferon reported in the domestic medical journals during the period 2000~2006 were collected and analyzed statistically. RESULTS:The ADR induced by interferon was more often seen in patients aged 30~39 years old(35.94%),with male showing higher proportion than female(68.75% vs. 31.25%).ADR more often occurred after multiple dosing and were characteriz-ed predominantly by allergic reactions of immune system in which multiple organs or systems may be involved.CONCLUSION:Interferon should be used rationally based on indications of medication and be closely monitored to prevent and reduce the occurrence of ADR.
8.Optimization on the Formulation Technology of Paeonol-?-cyclodextrin Inclusion Compound
China Pharmacy 2007;0(25):-
OBJECTIVE:To optimize the formulation technology of paeonol-?-cyclodextrin inclusion compound. METHODS: The formulation technology of paeonol-?-cyclodextrin inclusion compound was optimized by performing orthogonal experiment with the amount of ?-cyclodextrin,the solid-liquid ratio (ratio of ?-cyclodextrin to paeonol alcohol solution),the concentration of the envelop liquid (alcohol) as factors and the ultrasonic time was studied by single factor test and with the utilization ratio and entrapment efficiency of paeonol as indexes for evaluation. Meanwhile,a verification test was performed. RESULTS: The optimal formulation technology was as follows: the amount of ?-cyclodextrin was 8 g;the solid-liquid ratio was 1∶3;the concentration of the alcohol was 40% and the ultrasounding time was 40 min. The verification test revealed that the labeled contents were about 90% for all samples (4 batches). CONCLUSION: The optimized formulation technology is simple and reasonable,and it is applicable for the preparation of paeonol-?-cyclodextrin inclusion compound.
9.Association Between Serum Leptin Levels and Tumor Necrosis Factor-alpha Levels in Congestive Heart Failure
Journal of Chinese Physician 2001;0(02):-
Objective To observe the changes of serum leptin(LP) levels and serum tumor necrosis tactor-alpha(TNF?) concentrations and to explore the relationships with fasting serum insulin levels and congestive heart failure(CHF).Methods Serum leptin and inslin concentrations were measured by radioimmunoassay and tumor necrosis factor-alpha by ELISA.Body mass index(BMI),mean arterial blood pressure(MBP),fasting serum insulin(FINS),LP and TNF-alpha levels were determined in 40 patients with CHF and in 20 healthy controls matched for gender,age,BMI and MBP.The correlations between leptin and other parameters were analyzed.Results ⑴The fasting serum LP and FINS concentrations of patients with NYHA grade Ⅲ and NYHA grade Ⅳ were significantly lower as compared with the controls(P0 05).⑵The TNF alpha was higher in heart failure patients that in healthy controls(P
10.Determination of the Concentration of Zaleplon in Human Plasma by HPLC
China Pharmacy 1991;0(03):-
OBJECTIVE:To build up a method for determining the concentration of zaleplon in human plasma by HPLC. METHODS:The Kromasil-C 8 column was used and mobile phase consisted of methanol-water(65∶35);the flow rate was1.0ml/min,fluorescence excitation wave-length was233nm;fluorescence emission wave-length was460nm.RESULTS:The calibration curve revealed linearity in the concentration range of0.42~73.92ng/ml(r=0.9999)with a regressive equation of Y=1.870?147.The average recovery was99.47%.The with-day and between-day RSDs were4.9%and4.73%respec?tively.CONCLUSION:The method is accurate,reliable and highly sensitive so it can be used in study of pharmacokinetics of zaleplon.