1.A methodology study on assessment of cancer screening test.
Guo-fu GAO ; Fang-hui ZHAO ; Yan-ping WU ; Shou-de RONG ; Wen-hua ZHANG ; Qin-jing PAN ; Ling LI ; You-lin QIAO
Acta Academiae Medicinae Sinicae 2002;24(6):573-576
OBJECTIVETo analyze the effect of gold standard, blind comparison and different cut-points choosing on screening techniques assessment, and to promote the application of evidence-based medicine theory in screening study.
METHODSA screening study for cervical cancer in rural China in 1999, where 1997 women had been tested for pathology as gold standard and simulating situations without gold standard, blind comparison and under different cut-points. Indices such as detectable rate, sensitivity and specificity were calculated for each technique. Receiver operating characteristics (ROC) curves were drawn and areas under ROC curves between screening techniques were tested.
RESULTSWithout gold standard, diagnostic techniques could not be evaluated correctly, and without the blind comparison, the sensitivity and specificity of the tests would be subjectively increased. Furthermore, use of different cut-points led to different sensitivities and specificities of test.
CONCLUSIONSGold standard, blind comparison and perfect cut-points can improve the quality of screening test and drawing ROC curves is an effective way to confirm cut-points and evaluate diagnostic techniques. It is necessary to enforce the application of evidence-based medicine theory in scientific research.
Adult ; Clinical Laboratory Techniques ; methods ; Evaluation Studies as Topic ; Evidence-Based Medicine ; Female ; Humans ; Mass Screening ; Middle Aged ; ROC Curve ; Technology Assessment, Biomedical ; methods ; Uterine Cervical Neoplasms ; prevention & control
2.Construction and identification of infectious molecular clone of foot-and-mouth disease virus strain O/CHINA/99.
Jian-liang LV ; Yong-guang ZHANG ; Yong-lu WANG ; Li PAN ; Li-kuan LIU ; Shou-tian JIANG ; Wei-de ZHANG
Chinese Journal of Virology 2009;25(1):58-62
Nine primers were designed for the full-length genome of O/CHINA/99 and each sequence fragment was obtained by RT-PCR, and cloned into pOK12 vecter, the full-length genome cDNA clone of O/CHINA/99 was identified by restriction enzymes digestion, PCR, and the whole genome sequencing. The results showed that the O/CHINA/99 whole genome was formed with the length of 8200 nt. The nucleotide sequence of the full-length cDNA shared 99.1% homology with its prototype. RNA synthesized in vitro by means of a bacteriophage T7 promter inserted in front of the cDNA led to the production of infectious particle upon transfection of BHK-21 cell using lipofectamine reagent, as shown by cytopathic effects. The rescued virus had high pathogenicity in mice by endermic infection too. All the results showed that an infectious molecular clone was successfully constructed and rescued virus could be obtained.
Animals
;
Animals, Newborn
;
Cell Line
;
Cloning, Molecular
;
Cricetinae
;
DNA, Complementary
;
genetics
;
Foot-and-Mouth Disease
;
virology
;
Foot-and-Mouth Disease Virus
;
genetics
;
pathogenicity
;
Humans
;
Mice
;
Models, Genetic
;
Polymerase Chain Reaction
3.Double-balloon enteroscopy in detecting small intestinal bleeding.
Fa-chao ZHI ; Bing XIAO ; Bo JIANG ; Tian-mo WAN ; Yu GUO ; Dan ZHOU ; Li-hui WANG ; Jin-feng CHEN ; Lu XIE ; De-shou PAN ; Dian-yuan ZHOU
Chinese Medical Journal 2005;118(21):1834-1837
Adolescent
;
Adult
;
Aged
;
Child
;
Endoscopy, Gastrointestinal
;
methods
;
Female
;
Gastrointestinal Hemorrhage
;
diagnosis
;
pathology
;
Humans
;
Male
;
Middle Aged
4.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve