1.Comparative Study of CT and Nasal Endoscope(NE) in Diagnosis of Lesions of Nasal Cavity and Paranasal Sinu
Ying GUO ; Dapeng SHI ; Guangke WANG ; Zhenling YANG ; Anqi GUO
Journal of Practical Radiology 2001;0(06):-
Objective To compare the diagnostic value of CT and NE for lesions of nasal cavity and paranasal sinus area.Methods 80 cases of nasal and paranasal sinus diseases which were examined by both CT and NE at same period and proved by pathology.were reviewed.Results Compare with results of pathology,the accucy rate of both CT and NE was identical in diagnosing sinusitis and tumours of paranasal sinus,NE was higher than CT in nasal and paranasal sinus polyp and nasal cavity tumour,turbinate hyperplasia CT was higher than NE in paranasal sinus cyst and anatomic variations.Conclusion Pathologic biopsy can be taken under NE guide to understand the shape,texture and colour of the illness focus CT can show the size,shape and anatomy relation between lesion and its neighbor tissue.The diagnosis may more perfectly through NE combined with CT.
2.MRI Diagnosis and Clinical Study of Brain-stem Cavernous Angioma
Huili GUO ; Genhui SHUI ; Jingliang CHENG ; Dapeng SHI
Journal of Practical Radiology 1992;0(11):-
Objective To study MR imaging diagnostic value of brain-stem cavernous angioma(BCA).Methods 9 cases of BCA proved both surgically and pathologically with integrated clinical,MRI and pathological data were analyzed.Results The clinical attacks were divided into two types:the sudden and the resting.The MRI findings of BCA included:isointensity or hypointensity on T1WI(76.5%),isointensity or hyperintensity on T2WI(85.3%),heterogeneous mixed signal intensity on both T1WI and T2WI (36.2%),hypointense ring round angioma on T2WI (16.2%).On Gd-DTPA scanning,the lesions were slight enhancement or no enhancement in 8 cases.The shapes of lesions were round-like in most cases(86.6%),and typical moruloid or network in some cases(11.7%).The lesions localized in the midbrain in 3 cases,in the pons in 4,and in the medulla oblongata in 2.The histopathological findings included:composite pathological changes in most cades,elastic fibers in the angiomatous lacuna vasorum in 3 cases,visible drainage vein and supply artery in 2 cases.MRA showed hyperintensity around the angiomas in 5 cases.Conclusion MR imaging is of significant value in diagnosing BCA.
3.Development of Optometer Controlled by Micro-computer
Zhaoping GUO ; Zujin ZHANG ; Hui LI ; Dapeng LIU ; Hongyuan ZHANG
Chinese Medical Equipment Journal 1993;0(05):-
Objective To develop a new optometer controlled by micro-computer.Methods With AT89C51 single-chip as hardware and programmed by C language,the instrument applied,the optometer adopted LCD and international standard optotype.The optotype had 14 lines of object-finders,and only one line of random characters was displayed on the screen every time.The optometry distance was 3m.All procedures were controlled by singlechip.Results The case of memorizing eye-chart was avoided and the optometry was every simple.Conclusion The instrument eliminates mirror used for optometry short distance,and the optometry results can be stored and printed.It also has the merits of small volume,precise manufacture,simple operation,low cost and AC/DC power supply.
4.Clinical Application of Microcomputer Optometer
Zhaoping GUO ; Zujin ZHANG ; Hui LI ; Dapeng LIU
Chinese Medical Equipment Journal 2004;0(08):-
Objective To discuss the principle and clinical application of microcomputer optometer.Methods The optometer is composed of singlechip,handle and LCD.The eyesight is examined by selecting exposure of random sample eye-chart mark 'E' within direction keys on the handle.Results The optometer has the merits of simple manipulation,exact result,small cubage,AC/DC power supply and so on.Besides,it prevents the testee from remembering eye-chart.Conclusion The optometer can be extensively used in hospital,school,every work unit or even family.
5.The influence of drinking on high frequency hearing loss of pilot students.
Dapeng LI ; Honglei ZHANG ; Jia LI ; Rui GUO
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2014;28(19):1499-1501
OBJECTIVE:
To evaluate the influence of drinking on hearing loss of pilot students, especially on high frequency hearing loss.
METHOD:
According to whether drinking, 517 male pilot students were divided into two groups. The balance of all the factors in addition to drinking in both groups was compared. All the students were examined by pure tone audiometry. The statistical data of this research was processed based on a retrospective cohort study.
RESULT:
The damage of high frequency (4-8 kHz) auditory threshold in left and right ear in drinking group were obviously higher compared with control group (P < 0.01). The Morbidity of hearing loss in drinking group was significantly higher compared to control group (χ2 =16.620, P < 0.01).
CONCLUSION
Drinking is associated with the hearing loss in pilot students and particularly affects the hearing of high frequency spectrum.
Alcohol Drinking
;
adverse effects
;
Audiometry, Pure-Tone
;
Auditory Threshold
;
Cohort Studies
;
Deafness
;
Ear
;
Hearing
;
Hearing Loss
;
Hearing Loss, High-Frequency
;
Hearing Tests
;
Humans
;
Male
;
Retrospective Studies
;
Students
6.MR diffusion tensor imaging of optic nerve in anterior ischemic optic neuropathy at 3.0 T and correlation between diffusion tensor imaging and pattern visual evoked potential
Peihong QI ; Dapeng SHI ; Sibao LI ; Xirang GUO
Chinese Journal of Radiology 2014;48(12):992-995
Objective To study the value of MR diffusion tensor imaging (MR-DTI)using a 3.0 T scanner in anterior ischemic optic neuropathy(AION).Methods A total of 26 patients suffering from unilateral subacute AION were examined using DTI and pattern visual evoked potential(P-VEP).The parameters values of optic nerves including fractional anisotropy (FA),ADC,vertical diffusivity (λ⊥),paralleldiffusion (λ//),P100 value and amplitude were obtained.Paired t-tests were used for comparing the FA,ADC,λ⊥,and λ// values of the two groups.Correlations of DTI parameters and P-VEP parameters were analysed by using the Pearson rank correlation analysis.Results The values of FA,ADC,λ//,and λ_ in the affected nerve were 0.28±0.07,(1.43±0.20) ×103 mm2/s,(1.79±0.16) ×10-3 mm2/s,and (1.25±0.17) ×10-3 mm2/s respectively,and the corresponding values of unaffected nerve were 0.57±0.05,(1.04±0.17) ×10-3 mm2/s,(1.71 ±0.19) × 10-3 mm2/s,and (0.75±0.08) × 10-3 mm2/s respectively.Compared to unaffected contralateral nerves,the mean FA was reduced,the mean ADC,λ⊥ were increased in the affected nerves(t=-19.269,10.537,15.301,P<0.01).However,there were no significant difference of the λ//(t=l.632,P>0.05).There was significant negative correlation between ADC and P-VEP amplitude in affected optic nerves (r=-0.722,P<0.01).There was moderate negative correlation between λ⊥ and P-VEP amplitude in affected optic nerves (r=-0.634,P<0.01).There was moderate correlation between FA and P-VEP amplitude (r=0.539,P<0.01).There was no correlation between λ// and P-VEP amplitude.There was moderate negative correlation between FA and P-VEP P100 latency(r =-0.619,P<0.01).Conclusions DTI can sensitively detect diffusional abnormality of anterior ischemic optic neuropathy.DTI could be used as a supplemental way in the assessment of AION.
7.Different type of anesthesia affect radiation dose when do interventional therapy for patent ductus arteriosus
Shunqiang CHEN ; Ying GUO ; Dapeng SHI ; Enfeng WANG ; Zhong ZHANG
Journal of Practical Radiology 2016;32(8):1262-1264,1292
Objective To investigate radiation dose diffent type of anesthesia affected radiation dose when we do interventional therapy for child patent ductus arteriosus (PDA).Methods From 201 1 to 2014,we collected 50 children(3-6 years old)with PDA which received interventional therapy were included in the study.They were divided into two groups:group A (25 cases,male/fe-male=7/18,mean weight=1 5.32 kg±2.41 5 kg)underwent interventional therapy of PDA under general anesthesia,and group B (25 cases,male/female=13/12,mean weight=1 6.40 kg±2.056 kg)using local anesthesia.The surgery were operated by the same doctor,we used DSA children cardiovascular film AE mode (ped CARD)to monitor the surgery,image frames 1 5-30 f/s,used the non-ionic contrast agent (Iodixanol 320 mg I/mL)and recorded the child cumulative incidence of skin surface dose (AK),dose area product(DAP),and time of fluoroscopy,and do statistical analysis.Results All 50 cases were performed the surgery successfully. There were no significant difference of age,weight and gender between groups (age:t=1.924,P =0.06;weight:t =1.703,P =0.095;gender:χ2 =3.00,P =0.083).The cumulative incidence of skin surface dose (AK),dose area product (DAP)and time of fluoroscopy were (0.061±0.025)Gy,(5.08±2.19)Gy·cm2 and (3.15±1.16)min in A group,and (0.094±0.046)Gy,(8.41±3.587)Gy·cm2 , (6.86±3.27)min in B group.The sequence and image number of two groups were same.There were significantly differences of cumulative incidence of skin surface dose (AK),dose area product (DAP)and time of fluoroscopy between two groups (AK:t =3.152,P =0.003;DAP:t =3.957,P =0.000;time of fluoroscopy:t =5.346,P =0.000).The radiation doses of A group significantly lower than B group,compared with B group,the radiation dose were 40 percent [(1-5.08/8.41)%]lower in A group,the 1.1 7 times discrepancy of time of fluoroscopy between two group [(3.1 5-6.86)/3.1 5].Conclusion Radiation dose is associated with type of anesthesia. Compared with local anesthesia,radiation dose reduced 40% using general anesthesia during interventional therapy for PDA.
8.Diagnostic Value of CT Coronal Scan to Foreign Body in Bronchus of Children
Ying GUO ; Anqi GUO ; Tianming CHENG ; Dapeng SHI ; Yanling YU ; Yinghui GE
Journal of Practical Radiology 2001;0(09):-
Objective To evaluate diagnostic value of CT coronal scan to foreign body in bronchus of children.Methods 30 cases appearances of CT coronal scan to foreign body in bronchus of children were analysed.The appearances between CT coronal scan and axial scan,X-ray examination of chest were contrasted in some cases.Results Foreign body in bronchus or granuloma around part of foreign body were shown clearly by CT coronal scan in 30 cases,28 cases obstructive emphysema,13 cases obstructive pneumonia and 3 cases obstructive atelectasis were also shown clearly.Another,CT coronal scan showed the double margin sign of 16 cases diaphragm and 11 cases mediastinum.Conclusion CT coronal scan could show direct and indirect signs of the most foreign body in bronchus of children and it may be acte as primary examintion.
9.Effect of EMP on sex ratio of the offspring of male BALB/c mice
Jinhui LI ; Junye LIU ; Dapeng JIANG ; Xia MIAO ; Yafeng WANG ; Qiyan GUO ; Guozhen GUO
Chinese Journal of Radiological Medicine and Protection 2014;34(8):588-591
Objective To investigate the effects of EMP exposure to male BABL/c mice on the reproduction and its sex ratio.Methods Thirty-three male BALB/c mice were randomly divided into sham-exposed group,10 000 pulses/d exposed group,and 100 000 pulses/d exposed group with 50 Hz static magnetic field of 35 kV/m for 2 weeks consecutively,then the male mice were mated with unexposed females (1 male vs.2 female).Mated males were sacrificed to examine the exposure effects on sperm number and testis index after 7 days of mating.The sex ratio of embryos collected from unexposed mated females was investigated by PCR.Results The sex ratio of offspring was 0.298 (14/47) in the 10 000 pulses/d exposed group,significantly lower than 0.871 (27/31) in the sham-exposed group.No statistical changes were observed in the sex ratio of offspring,sperm number,the weights of testis and testis index after 100 000 pulses/d exposure.Conclusions The exposure of male mice to 35 kV/m EMP at 10 000 pulses/d for 2 weeks consecutively may change the sex ratio of mice's offspring.
10.Comparative Study on the Changes of DTI and DTT of Optic Radiation and the Defect of Visual Field
Hongguang FAN ; Dapeng SHI ; Xirang GUO ; Peihong QI ; Ang XUAN ; Liya LIU
Journal of Practical Radiology 2010;26(4):481-484
Objective To study the relationship between the changes of diffusion tensor imaging(DTI)and diffusion tensor tractography(DTT)of optic radiation and the defect of visual field.Methods DTI and DTT were performed in 37 patients with invasion of the optic radiation by intracranial lesions and in 20 normal control group at 3.0T MR scanner,the visual fields of all cases were examined.The relativity between FA values,ADC values and mean sensitivity(MS)values,mean defect(MD)values of visual field and the relativity between the morphological change of optic radiation and the defect of visual field were analysed.Results In comparison with control group,FA values decreased and ADC values increased in subject group,there were statistically significant differences(P<0.001)between them.In disordered group,FA values were positive correlation with MS values(r=0.718)and negative correlation with MD values(r=-0.694);ADC values were negative correlation with MS values(r=-0.625)and positive correlation with MD values(r=0.538).DTT showed that the ventral tracts of optic radiation were damaged which oppeared as the defect of ditto quadrant of bilateral field vision in 9 cases,the dorsal tracts and the lateral tracts of optic radiation were damaged which appeared as the defect of inferior quadrant of bilateral field vision in 7 cases,the optic radiations were damaged extensively that caused symmetric or asymmetric congruous hemianopia of bilateral field vision in 21 cases.Conclusion DTI and DTT of optic radiation are intimately correlated with the examined results of visual field,it will be a objective index to extimate the function and the morphological changes of optic radiation.