1.Experimental and Clinical Studies on the Effect of Sodium Dodecylbenzene Sulfonate in in vitro Killing Demodex and in Treating Demodicidosis
Yunshu ZANG ; Dajun WU ; Jianbo SONG
Chinese Journal of Parasitology and Parasitic Diseases 1987;0(04):-
Objective To observe the effect of sodium dodecylbenzene sulfonate (SDBS) in killing Demodex in vitro and in the treatment of demodicidosis. Methods ① The experiment of in vitro killing Demodex with 1% and 2% SDBS was conducted. ② A clinical trial was carried out to evaluate the therapeutic effect in the treatment of demodicidosis with 2% SDBS and 2% metronidazole emulsion. Patients with demodicidosis were randomly divided into trial and control groups (31 cases each). They were treated with 2% SDBS ointment and 2% metronidazole ointment twice a day in the early morning and evening respectively for eight weeks consecutively. Inflammatory lesions of face, Demodex infestation and scores of erythema were measured to evaluate the effect before and after treatment. ③ Follow-up was carried out for two months to evaluate the effect and side-effects after 8 weeks' treatment. Results ① 2% SDBS killed all Demodex in vitro after 5h, there was significant difference between the 2% SDBS and 2% metronidazole (69^4%), or between SDBS and peanut oil (9^1%)(P
2.To Improve Security Quality of Medical Treatment by Enhancing Management of Antibiotic Drug Usage
Guiming JIN ; Xiaochun WU ; Ren TANG ; Youying LIU ; Dajun CHEN
Chinese Journal of Nosocomiology 2004;0(10):-
OBJECTIVE To improve efficiency and quality of antibiotic drug usage in order to assure patients′ security of antibiotic drug usage. METHODS Inducted by strengthening security quality of medical treatment,we are bring antibiotic drug usage into medical quality management by using information technique,training medical workers,putting antibiotic drug into different classifications and surveillancing the usage of antibiotic drug.Moreover,we develop significant basic study for clinic to improve the level of rational use of drug. RESULTS Frequency and number of days for drug usage were reduced by putting measures into effect and inspecting numbers and sorts of drug usage.At the same time,we instituted individualized drug using scheme to critical patients,thereby many critical patients were retrieved. CONCLUSIONS Rational use of drug is a system project which must redeploy all enthusiasm and take comprehensive measures to fight for a safe,effective,economical goal in our work.
3.Evaluation of benign and malignant salivary gland tumors by CT perfusion
Xuefen ZHU ; Yuchun YAN ; Qiang WU ; Dajun FENG
Journal of Practical Stomatology 1996;0(02):-
0.05).Conclusion:The CT perfusion parameters can be regarded as a surrogate marker of tumor angiogenic activity,which is a useful method in estimating the degree of angiogenesis.
4.Biomechanical testing and evaluation of a self-made allograft interbody fusion cage at lumbar spine
Zimin XIANG ; Dajun YING ; Xuehui WU ; Jianzhong XU ; Weijun CHEN
Journal of Third Military Medical University 2002;0(12):-
Objective To evaluate the stability and compressive mechanical functions of the lumbar spine following insertion of a new self-made allograft interbody fusion cage.Methods Anti-bending intensity with three points test,anti-rotation intensity and compressive stiffness were measured at L4-L5 lumbar spine on five adult human fresh cadaveric specimens following insertion of a new self-made allograft interbody fusion cage and compared with that of before and after nucleus pulposus removal.Results The anti-bending intensity of flexion and extension of lumbar spine after inserting a new allograft interbody fusion cage was increased significantly(P
5.Observation on the Influence of Valsartan Combined with Bailing Capsules on Urinary Albumin Excretion Rate in Early Stage of Type 2 Diabetic Nephropathy
Li WU ; Dajun YAN ; Shijuan JING ; Jianmin YU ; Jilu GENG
China Pharmacist 2014;(9):1532-1533,1534
Objective:To observe the influence of valsartan combined with Bailing capsules on urinary albumin excretion rate in early stage of type 2 diabetic nephropathy ( DN) , and explore its protection in early DN. Methods:Sixty patients with early DN were randomly divided into two groups. On the basis of diet control and blood glucose regulation, the control group (n=30) was given valsartan 160 mg, qd, while the prevention group (n=30) was treated by valsartan (160 mg·d-1) combined with Bailing capsules (2. 0g, po, tid), and the treatment course was 12 weeks. The urinary albumin excretion rate ( UAER) , mean arterial blood pressure ( MAP) , serum creat-inine ( Scr) and hemoglobin A1c ( HbA1c) were measured and compared before and after the treatment in the two groups. Results:UAER in the two groups was significantly reduced after the treatment compared with that before the treatment (P<0. 01), and that in the prevention group was obviously lower than that in the control group (P<0. 01). MAP in the two groups was significantly decreased after the treatment as well (P<0. 01), while there was no significant difference between the two groups. Scr and Hb Alc in the two groups showed no significant changes before and after the treatment (P>0. 05). Conclusion:Valsartan combined with Bailing capsules shows certain effects in the treatment of early stage of type 2 diabetic nephropathy by decreasing the urinary albumin excretion.
6.Value of harmonic imaging diagnosis of very early stage of acute myocardial infarction by ultrasonic integrated backscatter
Xiaoqing WU ; Zhengyu YANG ; Dajun QIAN ; Qiang WANG ; Xiaoping BO ; Jianqiu ZHU
Chinese Journal of Ultrasonography 2003;0(11):-
Objective To study the very early diagnosis of acute myocardial infarction (AMI) by harmonic imaging integrated backscatter(IBS).Methods Thirty normal persons,12 cases at the very early stage of AMI (in 2 hours),36 cases with AMI (in 2-12 hours) were examined by IBS and the cyclic variation of integrated backscatter (CVIB) with HP Sonos 5500 ultrasonic system in different areas (the areas of myocardial infarction and no myocardial infarction).Results In the areas of AMI of the very early stage (in 2 hours),IBS was much higher than that of the areas of normal (14.7 vs 8.3,P
7.Early changes of cardiac structure and function after lung transplantation by echocardiography
Xiaoqing WU ; Jingyu CHEN ; Dajun QIAN ; Jun YANG ; Kaijian ZHAO ; Mingfeng ZHENG
Chinese Journal of Ultrasonography 2013;22(9):772-775
Objective To determine the changes of heart structure and function in early stage after lung transplant and to study the relationship between decreased pulmonary artery pressure and changes of heart structure and function.Methods 45 cases of lung transplant recipients were included in the study,their preoperative and postoperative echocardiography data were reviewed,and the postoperative early changes of cardiac structure and function were analysed.Then,the Pearson correlation analysis was used to compare the relationships between the decrease of pulmonary artery pressure and the changes of cardiac structure and function.Results After lung transplant,pulmonary artery systolic pressure(PASP) decreased significantly [(62.3 ± 27.2) vs (36.20 ± 7.8)mm Hg,P <0.01],and right ventricular dimensions zoomed down,tricuspid valve and pulmonary valve regurgitation reduced,left atrial diameter (LAD) and left ventricular end-diastolic diameter (LVDD) were enlarged,stroke volume (SV) increased [(43.85 ± 14.78) vs (58.68 ± 13.85)],but left ventricular ejection fraction (LVEF) was decreased [(69.31 ± 7.50)% vs (62.82 ± 8.12) %],those differences above were statistically significant (P < 0.05) compared with preoperative echocardiography date.Pearson linear correlation analysis show that after lung transplantation the more decreased PASP,the more increased LAD and LVDD,and the more decreased LVEF (P <0.05).Conclusions In early stage after lung transplant,the structure of right ventricular was quickly normalized,the function of right ventricular improved,LAD enlarged,SV increased,but left ventricular function reduced,there were a linear correlation between those changes and PASP reduced.Echocardiography has good reference value for early lung transplant patient.
8.Image characteristics of woven coronary artery on intravascular ultrasound and optical coherence tomography
Lingqiu KONG ; Yanwei LI ; Yong DONG ; Zhou WU ; Dajun HUANG ; Yongjun YIN ; Junbo GE
Chinese Journal of Ultrasonography 2021;30(1):20-24
Objective:To investigate the image characteristics of woven coronary artery (WCA)on intravascular ultrasound(IVUS) and optical coherence tomography(OCT).Methods:Thirty-seven patients suspected of WCA on coronary angiography were enrolled from Teaching Hospital of Chengdu University of Traditional Chinese Medcine, Zhengzhou Cardiovascular Disease Hospital and Zhongshan Hospital of Fudan University from January 2013 to July 2020. The intraluminal imaging features of WCA were analyzed using IVUS and OCT.Results:Of the 37 patients admitted at the cardiology service, 9 patients had WCA. All the patients underwent coronary angiography, IVUS and OCT, of which 6 lesions were located on the right coronary artery, 2 lesions were located on the left anterior descending artery and 1 patient had WCA on the circumflex artery. The mean length of WCA lesions was 2.2 cm(ranged from 1.2 cm to 4.5 cm). The angiographic appearance of WCA was numerous small tortious channels origined form the main lumen. The channels appeared to be " doughnut" like pattern and they merged to normal artery again after the anomalous segment. Flow limitation was rare unless there was coronary atherosclerosis. OCT and IVUS showed multiple spiral channels in the anomalous segment, which were independent of each other and each channels had a relatively complete three-layers vascular structure.Conclusions:With typical image characteristics, IVUS and OCT are able to screen out WCA and guide the treatment decision making.
9.Clinical analysis of 256 cases of facial plastic surgery in maxillofacial trauma
Chinese Journal of Primary Medicine and Pharmacy 2018;25(13):1720-1723
Objective To investigate the experience and effect of emergency cosmetic surgery for maxillofacial trauma.Methods From April 2011 to March 2017,256 patients with maxillofacial trauma in emergency cosmetic surgery in the People's Hospital of Lezhi County were selected in the study.The causes,locations,treatment methods and clinical effects were analyzed.Results In 256 cases,125 cases of traffic accident injury,68 cases of agricultural and industrial injury,48 cases of accidental injury,13 cases of asfights,2 cases of animal bites;of which 121 cases of lower face,73 cases of midface,39 cases of midface and lower face together,23 cases of upper face;98 cases of maxillofacial region fracture;105 patients had different degree of soft tissue defect.All patients the wound healed in primary healing,after stitches the wound healing in good contraposition,surface leveling,scar slender,facial features did not change significantly,no complications were observed.After 3-6 months of follow-up,the scar was not obvious and the appearance was satisfactory.Conclusion The clinical effect of emergency cosmetic surgery for maxillofacial trauma is satisfactory.Emergency cosmetic surgery can be used as an emergency treatment for maxillofacial trauma in primary hospital.
10.Study of the clinical value of medical history and clinical manifestation-based protocol for the diagnosis of spontaneous coronary artery dissection using intravascular ultrasound
Yanwei LI ; Lingqiu KONG ; Pan ZHANG ; Lincen ZOU ; Dajun HUANG ; Zhou WU ; Hongcai ZHANG ; Jue ZHAO ; Yong XU
Chinese Journal of Ultrasonography 2017;26(7):553-557
Objective To investigate the feasibility and clinical value of medical history and clinical manifestation-based protocol(MHCMP) for the diagnosis of spontaneous coronary artery dissection(SCAD)using intravascular ultrasound (IVUS).Methods Based on the MHCMP designed in our centre,intraoperative sequential analysis was performed in patients with acute coronary syndrom and clinical tip of SCAD,SCAD and its classification were defined according to the result of IVUS.Results Of the 37 patients admitted with ACS at the Cardiology Service,29 patients had SCAD as the cause(78.4 %).All the patients underwent coronary angiography and IVUS,of which 9 patiens were type I (24.3 %),15 patients were type Ⅱ (40.5%) and 5 patients were type Ⅲ (13.5%).The left anterior descending artery was the most frequently affected (16 patients),followed by the the right coronary artery (7 patients),while 5 patients had dissection of the circumflex artery and 1 patient had dissection of the left main coronary artery.Type I (evident arterial wall stain):this was the pathognomonic angiographic appearance of SCAD with contrast dye staining of the arterial wall with multiple radiolucent lumens.Type Ⅱ (diffuse stenosis of varying severity):this angiographic appearance was not well appreciated and was often missed or misdiagnosed.SCAD commonly involved the mid to distal segments of coronary arteries,and could be so extensive that it reached the distal tip.There was an appreciable (often subtle) abrupt change in arterial caliber,with demarcation from normal diameter to diffuse narrowing.This diffuse and usually smooth narrowing could vary in severity from inconspicuous mild stenosis to complete occlusion.Type Ⅲ (mimic atherosclerosis):this appearance was the most challenging to differentiate from atherosclerosis and most likely to be misdiagnosed,while IVUS was helpful for the differential diagnosis.Conclusions MHCMP is able to screen out all kinds of SCAD and guide the treatment decisions making.