1.Measurement Error Analysis and Calibration Technique of NTC - Based Body Temperature Sensor.
Chi DENG ; Wei HU ; Shengxi DIAO ; Fujiang LIN ; Dahong QIAN
Chinese Journal of Medical Instrumentation 2015;39(6):395-399
A NTC thermistor-based wearable body temperature sensor was designed. This paper described the design principles and realization method of the NTC-based body temperature sensor. In this paper the temperature measurement error sources of the body temperature sensor were analyzed in detail. The automatic measurement and calibration method of ADC error was given. The results showed that the measurement accuracy of calibrated body temperature sensor is better than ± 0.04 degrees C. The temperature sensor has high accuracy, small size and low power consumption advantages.
Body Temperature
;
Calibration
;
Humans
;
Monitoring, Physiologic
;
methods
2.The surgical skills of single-docking robot-assisted nephroureterectomy in rectus rectilinear cannula placement
Jia MIAO ; Haibin WEI ; Xinpeng CHEN ; Qi ZHANG ; Feng LIU ; Zujie MAO ; Enhui LI ; Xiaolong QI ; Lin QIAN ; Dahong ZHANG
Chinese Journal of Urology 2021;42(1):63-64
Single-docking robot-assisted laparoscopic radical nephroureterectomy is difficult to deal with the distal ureter and bladder. Thirty-two patients with ureter carcinoma underwent single-docking robot-assisted nephroureterectomy in rectus rectilinear cannula placement in our hospital. The advantages include lower surgical difficulty, shorter operation time, less surgical bleeding and damage. This surgical method is a safe and effective minimally invasive treatment for ureter carcinoma.
3.Analysis in risk factors of clinical inertia in treatment of patients with type 2 diabetes mellitus in suburbs of Shanghai
Tingting GUI ; Xiaoyi LU ; Qian LI ; Jia CHEN ; Yuanyuan XIAO ; Dahong ZHAI
Journal of Clinical Medicine in Practice 2024;28(23):121-125
Objective To explore the current status of clinical inertia in the treatment of patients with type 2 diabetes mellitus (T2DM) in the suburbs of Shanghai and analyze its risk factors. Methods A total of 1, 804 T2DM patients who visited the Endocrinology and Metabolism Clinic of Shanghai Sixth People's Hospital from November 2022 to November 2023 were selected as research objects. Patients were divided into clinical inertia group and non-clinical inertia group based on whether clinical inertia occurred during their treatment, and demographic and clinical data were collected. Logistic regression analysis was used to identify risk factors for clinical inertia in the treatment of T2DM patients. Results The incidence of clinical inertia in T2DM patients was 52.00% (938/1, 804). The results of multivariate Logistic regression analysis showed that longer diabetes duration, high level of glycated hemoglobin (HbA1c), high score of the Problem Areas in Diabetes Scale(PAID) score, taking over two oral medications, shorter life expectancy, and coexisting retinopathy were risk factors for clinical inertia in the treatment of T2DM patients (
4.Measurement Error Analysis and Calibration Technique of NTC- Based Body Temperature Sensor
Chi DENG ; Wei HU ; Shengxi DIAO ; Fujiang LIN ; Dahong QIAN
Chinese Journal of Medical Instrumentation 2015;(6):395-399
A NTC thermistor-based wearable body temperature sensor was designed. This paper described the design principles and realization method of the NTC-based body temperature sensor. In this paper the temperature measurement error sources of the body temperature sensor were analyzed in detail. The automatic measurement and calibration method of ADC error was given. The results showed that the measurement accuracy of calibrated body temperature sensor is better than±0.04oC. The temperature sensor has high accuracy, smal size and low power consumption advantages.