1.A multicenter study on the establishment and validation of autoverification rules for coagulation tests
Linlin QU ; Jun WU ; Wei WU ; Beili WANG ; Xiangyi LIU ; Hong JIANG ; Xunbei HUANG ; Dagan YANG ; Yongzhe LI ; Yandan DU ; Wei GUO ; Dehua SUN ; Yuming WANG ; Wei MA ; Mingqing ZHU ; Xian WANG ; Hong SUI ; Weiling SHOU ; Qiang LI ; Lin CHI ; Shuang LI ; Xiaolu LIU ; Zhuo WANG ; Jun CAO ; Chunxi BAO ; Yongquan XIA ; Hui CAO ; Beiying AN ; Fuyu GUO ; Houmei FENG ; Yan YAN ; Guangri HUANG ; Wei XU
Chinese Journal of Laboratory Medicine 2020;43(8):802-811
Objective:To establish autoverification rules for coagulation tests in multicenter cooperative units, in order to reduce workload for manual review of suspected results and shorten turnaround time (TAT) of test reports, while ensure the accuracy of results.Methods:A total of 14 394 blood samples were collected from fourteen hospitals during December 2019 to March 2020. These samples included: Rules Establishment Group 11 230 cases, including 1 182 cases for Delta check rules; Rules Validation Group 3 164 cases, including 487cases for Delta check; Clinical Application Trial Group 77 269 cases. Samples were analyzed for coagulation tests using Sysmex CS series automatic coagulation analyzers, and the clinical information, instrument parameters, test results, clinical diagnosis, medication history of anticoagulant and other relative results such as HCT, TG, TBIL, DBIL were summarized; on the basis of historical data, the 2.5 and 97.5 percentile of all data arranged from low to high were initially accumulated; on the basis of clinical suggestions, critical values and specific drug use as well as relative guidelines, autoverification rules and limits were established.The rules were then input into middleware, in which Stage I/Stage II validation was done. Positive coincidence, negative coincidence, false negative, false positive, autoverification pass rate, passing accuracy (coincidence of autoverification and manual verification) were calculated. Autoverification rules underwent trial application in coagulation results reports.Results:(1) The autoverification algorisms involve 33 rules regarding PT/INR, APTT, FBG, D-dimer, FDP,Delta check, reaction curve and sample abnormalities; (2)Autoverification Establishment Group showed autoverification pass rate was 68.42% (7 684/11 230), the false negative rate was 0%(0/11230), coincidence of autoverification and manual verification was 98.51%(11 063/11 230), in which positive coincidence and negative coincidence were respectively 30.09% (3 379/11 230) and 68.42%(7 684/11 230); Autoverification Validation Group showed autoverification pass rate was 60.37%(1 910/3 164), the false negative rate was 0%(0/11 230), coincidence of autoverification and manual verification was 97.79%(3 094/3 164), in which positive coincidence and negative coincidence were respectively 37.42%(1 184/3 164) and 60.37%(1 910/3 164); (3) Trialed implementation of these autoverification rules on 77 269 coagulation samples showed that the average TAT shortened by 8.5 min-83.1 min.Conclusions:This study established 33 autoverification rules in coagulation tests. Validation showedthese rules could ensure test quality while shortening TAT and lighten manual workload.
2.The combined therapeutic effects of iodine-labeled multifunctional copper sulfide-loaded microspheres in treating breast cancer.
Qiufang LIU ; Yuyi QIAN ; Panli LI ; Sihang ZHANG ; Zerong WANG ; Jianjun LIU ; Xiaoguang SUN ; Michael FULHAM ; Dagan FENG ; Zhigang CHEN ; Shaoli SONG ; Wei LU ; Gang HUANG
Acta Pharmaceutica Sinica B 2018;8(3):371-380
Compared to conventional cancer treatment, combination therapy based on well-designed nanoscale platforms may offer an opportunity to eliminate tumors and reduce recurrence and metastasis. In this study, we prepared multifunctional microspheres loading I-labeled hollow copper sulfide nanoparticles and paclitaxel (I-HCuSNPs-MS-PTX) for imaging and therapeutics of W256/B breast tumors in rats. F-fluordeoxyglucose (F-FDG) positron emission tomography/computed tomography (PET/CT) imaging detected that the expansion of the tumor volume was delayed (<0.05) following intra-tumoral (i.t.) injection with I-HCuSNPs-MS-PTX plus near-infrared (NIR) irradiation. The immunohistochemical analysis further confirmed the anti-tumor effect. The single photon emission computed tomography (SPECT)/photoacoustic imaging mediated by I-HCuSNPs-MS-PTX demonstrated that microspheres were mainly distributed in the tumors with a relatively low distribution in other organs. Our results revealed that I-HCuSNPs-MS-PTX offered combined photothermal, chemo- and radio-therapies, eliminating tumors at a relatively low dose, as well as allowing SPECT/CT and photoacoustic imaging monitoring of distribution of the injected agents non-invasively. The copper sulfide-loaded microspheres, I-HCuSNPs-MS-PTX, can serve as a versatile theranostic agent in an orthotopic breast cancer model.