1.Correlation between anterior chamber angle diameter and ciliary sulcus distance measured by Suowei panoramic 50-MHz digital ultrasound blomicroscopy
De-jiao, LI ; Ning-li, WANG ; Da-peng, MU
Chinese Journal of Experimental Ophthalmology 2011;29(10):918-921
Background Measurement of ciliary sulcus distance is important for phakic intraocular lens implantation.Suowei panoramic 50-MHz digital ultrasound biomicroscopy makes it possible for the direct measurement of ciliary sulcus distance.Objective The aim of this study was to investigate the correlation between anterior chamber(AC)angle diameter and ciliary sulcus distance in different AC depth population and offer a clinical guide.Methods The anterior chamber angle diameter and ciliary sulcus distance were measured in 30 right eyes with shallow anterior chamber caused by suspect glaucoma and 30 right eyes with deep anterior chamber dut to the high myopia with Suowei panoramic 50-MHz digital ultrasound biomicroscopy.Three horizontal B-scans with the focal plane approximately at a depth corresponding to the iris plane were acquired for each eye.The differences of the anterior chamber angle diameter and ciliary sulcus distance were calculated and compared between the two groups.The correlation of the anterior chamber angle diameter and ciliary sulcus distance were evaluated in respective group.Results In shallow AC group,the mean angle diameter was(11.49+0.75)mm,the mean ciliary sulcus distance was (10.97±0.86)mm with the mean standard deviation of the difference of(-5.14± 0.55)mm,showing a statistically significant difference(t =-5.092,P =0.000).In shallow AC group,linear regression analysis showed a statistically significant correlation between ciliary sulcus distance and angle diameter(R2=0.593,P=0.000)and the Pearson's correlation coefficient was 0.767.In deep AC group,the angle diameter was(12.69±0.67)mm;while ciliary sulcus distance was(12.31 ± 0.61)mm with the mean slandard deviation(-0.38 ± 0.17)mm,which was statistically significantly different(t=-5.531,P=0.000).The ciliary sulcus distance was found to be linear correlation with the angle diameter(R2 =0.699,P=0.000)and Pearson' s correlation coefficient of 0.836.Conclusions Panoramic ultrasound biomicroscopy is an useful tool to the measurement of ciliary sulcus distance.This study exhibited that the ciliary sulcus distance is significant associated with the anterior chamber angle diameter,which may offer a guide for phakic intraocular lens implantation.
2.Effect of miR-145 on NSCLC cell proliferation and FSCN1 protein expression
Zhimin MU ; Guangxian MAO ; Yuancai XIE ; Xuxing PENG ; Da WU
Chinese Journal of Biochemical Pharmaceutics 2015;(3):25-27
Objective To investigate the effect of miR-145 on human lung adenocarcinaoma A549 cell proliferation and FSCN1 expression. Methods pmR-mcherry/miR-145 was constructed and transfected into A549 cell,then the expression of miR-145 and the proliferation of A549 cell were verified by QPCR and MTS assay, respectively.The situation of FSCN1 expression in A549 cell was detected by Western blot.Results pmR-mcherry/miR-145 vector was constructed successfully,and QPCR results indicated that miR-145 expressed effectively.Western blot results showed that FSCN1 was one of the targets of miR-145 in A549 cell.MTS assay results indicated that miR-145 inhibited the proliferation of A549 cell.Conclusion Overexpression of miR-145 can inhibit the proliferation of A549 cell, and FSCN1 was one of its target.
3.Intracerebral transplantation of human umbilical cord-derived mesenchymal stem cells in neonatal rat model of hypoxic-ischemic brain damage: protective effect to injured brain.
De-Shuang ZHANG ; Xiao-Hong BAI ; Da-Peng CHEN ; De-Zhi MU ; Juan CHEN
Chinese Journal of Contemporary Pediatrics 2014;16(9):927-932
OBJECTIVETo study the brain protection and the possible mechanism of human umbilical cord-derived mesenchymal stem cells (hUC-MSCs) in neonatal rat model of hypoxic-ischemic brain damage (HIBD).
METHODSSuccessfully establishing a neonatal rat model of HIBD, hUC-MSCs labeled with BrdU were transplanted into the lateral ventricle 24 hours after HIBD. The number of apoptotic cells and the expression of Caspase-3 were detected by TUNEL and Western blot respectively at 24 and 48 hours after transplantation. The neurological functions of HIBD rats were evaluated by Longa score, and the survival, differentiation and pro-differentiation effects of hUC-MSCs were identified by immunofluorescence at 1 to 3 weeks after transplantation.
RESULTSAt 24 and 48 hours after transplantation, apoptotic cells and Caspase-3 expression in the MSCs group were less than in the HIBD group (P<0.05). At 2 and 3 weeks after transplantation, the Longa score in the MSCs group was lower than in the HIBD group (P<0.05). After transplantation, positive cells labeled with BrdU were seen in the brain tissue. The expression levels of glial fibrillary acidic protein (GFAP) and neuron specific esterase (NSE) in the MSCs group were higher than in the HIBD and sham-operated control groups (P<0.05), and increased gradually with the transplantation time (P<0.05).
CONCLUSIONShUC-MSCs transplantation in HIBD rats can inhibit Caspase-3 expression and reduce apoptotic cells in the early stage, and in the later period, the survival hUC-MSCs can differentiate into neural-like cells and promote the differentiation of endogenous neural-like cells, providing protective effects to brain.
Animals ; Animals, Newborn ; Apoptosis ; Caspase 3 ; metabolism ; Cell Differentiation ; Cord Blood Stem Cell Transplantation ; Disease Models, Animal ; Female ; Hypoxia-Ischemia, Brain ; pathology ; therapy ; Male ; Mesenchymal Stem Cell Transplantation ; Phosphopyruvate Hydratase ; analysis ; Rats ; Rats, Sprague-Dawley
4.Accuracy and repeatability of direct ciliary sulcus diameter measurements by full-scale 50-megahertz ultrasound biomicroscopy.
De-jiao LI ; Ning-li WANG ; Shu CHEN ; Shu-ning LI ; Da-peng MU ; Tao WANG
Chinese Medical Journal 2009;122(8):955-959
BACKGROUNDPhakic intraocular lens (pIOL) implantation has been a popular means for the treatment of high ametropia. Measurements of ciliary sulcus diameter is important for pIOL size determining. But till now, no perfect system can directly measure it. The present study was to evaluate the accuracy, repeatability and reproducibility of direct sulcus diameter measurements obtained by a full-scale 50-megahertz (MHz) ultrasound biomicroscopy (UBM).
METHODSA fresh cadaver human eye with a scale marker inserted through the posterior chamber plane from 3 o'clock to 9 o'clock meridian and 30 randomly selected eyes from 30 normal subjects were scanned by full-scale 50-MHz UBM in horizontal meridional scan plane. The distance between the scales and the whole length of the marker inside the cadaver eye were measured by the same observer using the "built-in" measurement tools and the indicating error of instrument was calculated. Reproducibility of the measurement was evaluated in 30 eyes by 2 operators using Blander and Altman plot test. Repeatability was evaluated from 10 successive eyes randomly selected from the 30 eyes by one operator.
RESULTSOn a scale of 1 mm, the greatest indicating error was 40 microm; the mean largest indicating error of 1 mm scale from the 10 images was (26 +/- 14) microm; on a scale of 11 mm, the greatest indicating error was 70 microm; the error rate was 0.64%. The mean length of the needle inside the eye of the 10 images was 11.05 mm, with the mean indicating error of 47 microm, the average error rate was 0.43%. For ciliary sulcus diameter measurements in vivo, the coefficient of variation was 0.38%; the coefficients of repeatability for intra-observer and inter-observer measurements were 1.99% and 2.55%, respectively. The limits of agreement for intra-observer and inter-observer measurement were -0.41 mm to 0.48 mm and -0.59 mm to 0.58 mm, respectively.
CONCLUSIONThe full-scale 50-MHz UBM can be a high accuracy and good repeatability means for direct measuring the ciliary sulcus diameter and useful for size determining of posterior chamber pIOL.
Ciliary Body ; diagnostic imaging ; Humans ; In Vitro Techniques ; Lenses, Intraocular ; Microscopy, Acoustic ; methods ; standards ; Reproducibility of Results
5.Study on preparation of ligustrazine ocular implant and correlation between in vivo and in vitro drug release.
Jun-Hua WEI ; Pei LI ; Peng-Kai MA ; Hong-Jie MU ; Da-Quan CHEN ; Kao-Xiang SUN
China Journal of Chinese Materia Medica 2013;38(8):1160-1164
OBJECTIVETo prepare ligustrazine (TMPZ) ocular sustained-release implant, and investigate its in vitro drug release, pharmacokinetics in rabbit vitreum and in vitro correlation.
METHODLigustrazine ocular sustained-release implants were prepared by micro-twin conical screw mixers with hot-melting extrusion method, with polyactic-co-glycolic acid (PLGA) as the matrix. HPLC was adopted to determine the concentration in vitreum after ligustrazine was implanted in rabbit eyes, in order to examine its in vivo sustained-release behavior, and study the correlation between in vitro and in vivo.
RESULTLigustrazine implants were prepared with a drug-loading rate between 10% and 30%, which was in conformity to the pharmacopoeia in terms of the content uniformity. Its in vitro release was in conformity to the zero-order release model. With PLGA 5050, 2. 5A as a vector, ligustrazine implants with a drug-loading rate of 30% could slowly release drug for more than 3 weeks, indicating a good correlation between in vitro and in vivo release.
CONCLUSIONLigustrazine ocular implants prepared with hot-melting extrusion method is practicable. Ligustrazine ocular implants release drug smoothly in rabbit vitreous vitreums, suggesting good sustained-release effect.
Animals ; Biological Availability ; Drug Implants ; Eye ; Female ; Male ; Polyglycolic Acid ; chemistry ; Pyrazines ; administration & dosage ; chemistry ; pharmacokinetics ; Rabbits ; Vitreous Body
6.Visualization study of current research on nutrition of premature infants in China.
Xiao-Yan YANG ; Chao CHEN ; Jun TANG ; Da-Peng CHEN ; De-Zhi MU
Chinese Journal of Contemporary Pediatrics 2013;15(10):835-840
OBJECTIVEInadequate postnatal nutritional support is an important factor contributing to growth failure, which leads to poor neurological outcome. In this study, co-word analysis was used to investigate the research on nutrition of premature infants over the last six years in China, describe the research trend in this field in China, and provide possible directions for future research.
METHODSA literature search was performed in January 2013 using the CNKI database and the key words "preterm infant" and "nutrition". A total of 772 articles were retrieved. Then high-frequency key words were extracted using Excel 2010 to create a co-occurrence matrix. Finally, a visualized network was built using Ucinet 6.0.
RESULTSThe knowledge domain map of research on nutritional support for premature infants in China showed that the major topic of relevant research is still the combination of parenteral nutrition and enteral nutrition, with the goal of maintaining appropriate growth rates in premature infants. Researchers have paid much attention to the adverse effects of parenteral nutrition. Feeding intolerance is still the main problem in nutritional support, especially enteral nutrition, for premature infants.
CONCLUSIONSA visualized network of current research on nutrition of premature infants in China has been created, and a knowledge domain map has been drawn to reflect the hot topics in this field of study over the last six years.
Enteral Nutrition ; Humans ; Infant Nutritional Physiological Phenomena ; Infant, Newborn ; Infant, Premature ; physiology ; Parenteral Nutrition
7.Evaluation of the effect of up-converting phosphor technology in detection of plague antigen-antibody by receiver operating characteristic curve method
Jin-xiao, XI ; Hong, ZHANG ; Peng-fei, GE ; Li-min, GUO ; Wen-ping, DA ; Bin, WU ; Da-qin, XU ; Shi-ming, WANG ; Wei-min, PAN ; Ke-jun, MIAO ; Ya-jun, GE ; Tao-xia, MU ; Guo-juan, CHEN
Chinese Journal of Endemiology 2012;31(6):640-642
Objective To evaluate the effect of up-converting phosphor technology(UPT) in detection of plague antigen-antibody by receiver operating characteristic curve (ROC) method,and to provide a scientific basis for field application of UPT rapid detection technology in plague prevention and control.Methods Two hundred and twenty four serum samples were collected from Marmots and ground squirrels in the plague foci,Yersinia pestis antibody was detected by UPT,ELISA,Colloidal-gold Strips and IHA,respectively; 108 organs and bone marrow samples were collected,and Yersinia pestis antigens were detected by UPT,ELISA,PCR and RIHA,respectively.IHA was used as the gold standard for antibody test results,RIHA,PCR + Colloidal-gold Strips,PCR + ELISA were used as the gold standard for antigen test results.The results were evaluated using ROC method.Results Antibodies detection:the AUCs of UPT,ELISA and Colloidal-gold Strips were greater than 0.5.The difference between UPT and other methods was not statistically significant (z =1.204,P > 0.05).Antigen detection:the AUCs of UPT,ELISA,Colloidal-gold Strips and PCR were greater than 0.5.There was no statistical difference between UPT and other methods(z =0.866,P > 0.05).Conclusions UPT as a new technology works well in the detection of plague antigen-antibody.The technology is simple,fast,accurate,and suitable for on-site monitoring of plague,emergency treatment of sudden plague,and suitable for promotion.
8.Investigation of pharmacokinetics and pharmacodynamics of different doses of aminophylline in very low birth weight infants.
Xiao-Yan YANG ; Jing ZHAO ; Jing SHI ; Jin-Lin WU ; Da-Peng CHEN ; Jun TANG ; Ying XIONG ; De-Zhi MU
Chinese Journal of Contemporary Pediatrics 2015;17(11):1171-1175
OBJECTIVETo study the pharmacokinetic and pharmacodynamic features of different doses of aminophylline in very low birth weight (VLBW) infants with different postmenstrual ages, weights, and ages (in days).
METHODSA total of 40 VLBW infants with apnea were enrolled. After an intravenous loading dose of 5 mg/kg aminophylline, they were randomized into two groups with different maintenance doses of aminophylline (1 mg/kg and 2 mg/kg, once every 8 hours). Blood concentrations of aminophylline and liver and renal functions were monitored at 8 hours, 3 days, and 7 days after the loading dose. Attacks of apnea were documented. Pharmacokinetic data of aminophylline were compared between the two groups.
RESULTSThe steady-state plasma concentration of aminophylline and plasma clearance in the 2 mg/kg group were significantly higher than those in the 1 mg/kg group (P<0.05). However, the elimination half life was shorter in the 2 mg/kg group (P<0.05). Days of apnea attacks within 7 days after birth in the 2 mg/kg group were significantly fewer than in the 1 mg/kg group (P<0.05). Aminophylline plasma clearance was positively correlated with age (in days) after birth and postmenstrual age in both groups.
CONCLUSIONSIn VLBW infants, pharmacokinetics and pharmacodynamics are different when different maintenance doses of aminophylline are given. The maintenance dose of 2 mg/kg is associated with a better effect in the treatment of apnea. Postmenstrual age and age (in days) should be considered during the adjustment of dose, and routine blood concentration monitoring should be performed.
Aminophylline ; pharmacokinetics ; pharmacology ; Apnea ; drug therapy ; Female ; Humans ; Infant, Newborn ; Infant, Very Low Birth Weight ; Male
9.Measurement of anterior chamber volume with rotating scheimpflug camera and anterior segment optical coherence tomography.
Jing FU ; Shu-ning LI ; Xiao-zhen WANG ; Ge-wei WU ; Da-peng MU ; Jian WANG ; Ning-li WANG
Chinese Medical Journal 2010;123(2):203-207
BACKGROUNDMeasurement of anterior segment parameters plays an important role in diagnosis and treatment of glaucoma. The objective of this study was to evaluate the repeatability and reproducibility of anterior chamber volume (ACV) measurements with rotating scheimpflug camera (RSC) and to examine agreement with anterior segment optical coherence tomography (AS-OCT).
METHODSThirty nine healthy normal subjects were recruited from the Eye Center of Tongren Hospital. ACV was measured using RSC and AS-OCT in a randomly selected eye for each subject. For RSC measurements, both automatic and manual ACV measurements and 2 independent operators' ACV measurements were obtained. All subjects were invited for 3 visits within a week to evaluate repeatability and reproducibility of ACV measurement by RSC. Agreement was evaluated between RSC and AS-OCT.
RESULTSGood repeatability and reproducibility were found for both automatic and manual ACV measurements obtained by RSC. For intrasession repeatability, coefficient of variation (CVw) and intraclass correlation coefficient (ICC) values for automatic were 3.52% and 0.98; the values for manual were 3.44% and 0.97, respectively. For intersession reproducibility, the respective CVw and ICC values were 3.96% and 0.96. Good agreement was also found in 2 operators for both automatic and manual ACV measurements; nevertheless, poor agreement was found between RSC and AS-OCT (95% confidence interval (CI) for agreement of automatic RSC measurement versus AS-OCT were -96.3 to 72.8 microl and 95% CI for agreement of manual RSC measurement versus AS-OCT were between -41.7 to 10.1 microl).
CONCLUSIONSBoth RSC automatic and manual ACV measurements showed good repeatability and reproducibility, and showed comparable agreement between 2 independent operators, but poor agreement was found between RSC and AS-OCT.
Adult ; Anterior Chamber ; anatomy & histology ; Anterior Eye Segment ; anatomy & histology ; Cornea ; anatomy & histology ; Diagnostic Techniques, Ophthalmological ; instrumentation ; Female ; Glaucoma ; diagnosis ; Humans ; Male ; Reproducibility of Results ; Tomography, Optical Coherence ; methods ; Young Adult
10.Short-term effects of ambient air pollution and cause-specific emergency department visits in Guangzhou
Wei-yun HE ; Yan WU ; Pi GUO ; Jia-yun LV ; Yu-liang CHEN ; Mu-rui ZHENG ; Peng-da LIU ; Li BU ; Wen-ru FENG
Chinese Journal of Disease Control & Prevention 2019;23(7):828-834
Objective To understand the relationship between the concentration of air pollutants and daily emergency department visits for different diseases (circulatory system disease, digestive system disease, nervous system disease and respiratory system disease) in Guangzhou, Guangdong Province. Methods The daily average concentrations of sulfur dioxide (SO2), nitrogen dioxide (NO2, carbon monoxide (CO) and PM2.5 and the daily maximum 8-hour concentrations of O3, the daily average temperature, the relative humidity and cause -specific emergency department visits of the four major diseases from 2015 to 2017 were collected in Guangzhou. Semi-parametric generalized additive model was used to analyze the relationship between the concentration of pollutants and daily cause-specific emergency department visits. Results The daily average concentrations of SO2, NO2, CO, O3 and PM2.5 during the study period were 13.24 μg /m3, 45.96 μg /m3, 0.97 mg /m3, 123.77 μg /m3 and 36.22 μg /m3, respectively. For circulatory system disease,the independently significant associations of SO2 with emergency department visits in single-pollutant models (2.91%, 95% CI: 1.00%-4.85%), and multipollutant models (4.39%, 95% CI: 1.22%-7.67%) were observed. Conclusion The ambient SO2 increases the risk of emergency department visits due to circulatory diseases in Guangzhou. Comprehensive prevention and control measures should be taken to reduce the emission of SO2.