1.Low-temperature crystallization on porous titanium and in vivo evaluation on bone-bonding mechanics of the treated titanium.
Yong-wu LI ; Da-nong CHEN ; Xian-jun DING ; Jing-ming WU
Chinese Journal of Medical Instrumentation 2007;31(4):245-247
By the bioactivity technology of Low-Temperature Preparation of Anatase and Rutile Layers on porous Titanium Substrates, CPTi(Commercially pure titanium Phi4.0 mm x 20 mm) was processed and treated as experiment specimens while CPTi was treated as control specimens. Experiment specimens and control specimens were implanted into the holes (4.0 mm in diameter) in rabbit's right and left tibias respectively. After implantation for predetermined periods of 4,8,12, 16 weeks, the specimens were taken out with bone tissues, and were examined by a press-out tester to evaluate the shearing force between the implant and the bone tissue. It is found that the shearing force between the experiment specimen and the bone is more significantly higher than that between the control specimen and the bone, and the bonding time is shorter, the stabilization time is faster. This study has laid down a good foundation for the titanium metal's innovative applications in clinical orthopaedics.
Animals
;
Bone Substitutes
;
chemistry
;
Bone and Bones
;
Cold Temperature
;
Crystallization
;
Materials Testing
;
Orthopedic Fixation Devices
;
Prostheses and Implants
;
Rabbits
;
Tibia
;
Titanium
;
chemistry
2.Study on the preparation and application of individual artificial bone with carbon/carbon composites.
Xinye NI ; Nong QIAN ; Dong ZHOU ; Yunliang MIAO ; Xinbo XIONG ; Tao LIN ; Da CHEN ; Gongyin ZHAO ; Ping ZHONG
Journal of Biomedical Engineering 2013;30(6):1265-1271
The present paper is aimed to study the preparation and application of individual artificial bone of carbon/carbon composites. Using computer tomography images (CT), we acquired a three-dimensional image. Firstly, we described bone contour line outlined with manual and automatic method by the binary volume data. Secondly, we created 3D object surface information by marching cubes. Finally, we converted this information to non-uniform rational B-spine (NURBS) by using geomagic software. Individual artificial bone with carbon/carbon composite was prepared through the CNC Machining Center. We replaced the humeral head of the tested rabbit, and then observed the effects of implantation in neuroimaging and pathological section. Using this method, we found that the bone shape processed and bone shape replaced was consistent. After implantation, the implant and the surrounding bone tissue bound closely, and bone tissue grew well on the surface of the implant. It has laid a sound foundation of the preparation using this method for individual artificial bone of carbon/carbon composite material.
Animals
;
Bone Substitutes
;
chemistry
;
Carbon
;
chemistry
;
Imaging, Three-Dimensional
;
Rabbits
;
Software
;
Tomography, X-Ray Computed
3.The application of 3D liver acquisition volume acceleration integrated with array spatial sensitivity encoding technique in liver dynamic-enhancement scanning.
Wei WU ; Jian-nong ZHAO ; Da-jing GUO ; Wei-bo XIE ; Wei-jia ZHONG ; Yin-deng LUO ; Wei-juan CHEN
Chinese Journal of Hepatology 2008;16(4):294-297
OBJECTIVETo evaluate the application of 3D liver acquisition volume acceleration (3D-LAVA) integrated with array spatial sensitivity encoding technique (ASSET) in liver dynamic-enhancement scanning.
METHODSOne hundred forty-seven patients underwent conventional plain and contrast enhancement liver MR imaging. 3D-LAVA and 2D fast spoiled gradient recalled echo were used for contrast enhancement liver MR scanning in 90 and 57 patients respectively. In the 3D-LAVA group, integrated ASSET was used in 72 out of the 90 patients. Of the 57 patients who underwent examinations using 2D fast spoiled gradient recalled echo, portal vein CE-MRA was performed on 20. The ability of 3D-LAVA to detect the lesions and the advantage to shorten the acquisition time after integrating with ASSET were analyzed. Original images of 60 patients in the 3D-LAVA group were processed using MIP to illustrate the anatomy of the portal vein. They were compared with those shown by CE-MRA to evaluate the illustration abilities of the two approaches.
RESULTS3D-LAVA is more sensitive than 2D-FSPGR in detecting metastatic hepatic carcinomas. In the 3D-LAVA group integrated with ASSET, earlier and peak arterial phase images were acquired in 34 cases; and earlier, peak and late arterial phase images were acquired in 23 cases. The illustrations of the portal vein anatomy by 3D-LAVA were similar to those shown by portal vein CE-MRA.
CONCLUSION3D-LAVA integrated with ASSET can obtain higher quality multi-phase dynamic enhancement images of the liver in a shorter time, and in the meantime also shows the vascular anatomy.
Adolescent ; Adult ; Aged ; Aged, 80 and over ; Contrast Media ; Female ; Humans ; Image Enhancement ; methods ; Image Interpretation, Computer-Assisted ; Imaging, Three-Dimensional ; methods ; Liver ; pathology ; Male ; Middle Aged ; Sensitivity and Specificity ; Young Adult
4.Multicenter clinical study on the efficacy and safety of inhalable insulin aerosol in the treatment of type 2 diabetes.
Zhi-hong LIAO ; Ying-li CHEN ; Fang-ping LI ; Xiang YAN ; Hai LU ; Li YAN ; Zhi-guang ZHOU ; Da-long ZHU ; Li-nong JI ; Jian-ping WENG ; null
Chinese Medical Journal 2008;121(13):1159-1164
BACKGROUNDA new inhalable insulin aerosol (Inh-Ins) was developed in China. The aim of this multicenter clinical study was to evaluate the efficacy and safety of this new Inh-Ins as a treatment of type 2 diabetes. Regular porcine insulin (RI) was used as a control.
METHODSThis study is a prospective, randomized, open-label, parallel-group multicenter clinical trial in which 253 qualified patients with type 2 diabetes received the insulin Glargine daily at bedtime plus either a pre-meal Inh-Ins or a pre-meal subcutaneous RI for 12 weeks. HbA1c, fasting plasma glucose (FPG), the 1-hour-postprandial blood glucose (1hPBG) and the 2-hour-postprandial blood glucose (2hPBG) were measured. Events were monitored for adverse effects.
RESULTSAfter 12 weeks, the HbA1c decreased significantly from baseline in both treatment groups, with no significant difference between the two regimens. In the Inh-Ins group, FPG, both 1hPBG and 2hPBG significantly declined from baseline after the 8th- and 12th-weeks of treatment. The reduced values of FPG or 1hPBG between the two groups showed a more significant hypoglycemic effect with the Inh-Ins than the RI. After 12 weeks, the pulmonary carbon monoxide diffusing capacity (DLco) was significantly lower in Inh-Ins group than in the RI. The main side effects of Inh-Ins were coughing, excessive sputum, and hypoglycemia.
CONCLUSIONSInh-Ins was effective in decreasing HbA1c like the RI. It was better in lowering the FPG and the 1hPBG than the RI. Its main side effects were coughing, excessive sputum, and hypoglycemia. Also, Inh-Ins slightly impaired DLco.
Adolescent ; Adult ; Aerosols ; Aged ; Blood Glucose ; analysis ; Body Weight ; drug effects ; Cough ; chemically induced ; Diabetes Mellitus, Type 2 ; blood ; drug therapy ; Female ; Glycated Hemoglobin A ; analysis ; Humans ; Hypoglycemia ; chemically induced ; Insulin ; administration & dosage ; adverse effects ; Male ; Middle Aged ; Prospective Studies
5.1H magnetic resonance spectroscopy in the evaluation of high intensity focused ultrasound ablation for primary liver cancer.
Yin-Deng LUO ; Wei-Jia ZHONG ; Jian-Nong ZHAO ; Da-Jing GUO ; Wei WU ; Wei-Juan CHEN ; Wei-Bo XIE ; Xiao-Ping LUO
Chinese Journal of Hepatology 2011;19(2):102-105
To investigate the clinical value of 1H magnetic resonance spectroscopy (1H MRS) in the evaluation of high intensity focused ultrasound (HIFU) ablation for primary liver cancer. Routine magnetic resonance sequences, contrast-enhanced magnetic resonance imaging and respiratory-triggered single voxel point resolved spectroscopy sequence (PRESS) were performed on 24 patients with primary liver cancer before and after HIFU ablation. A respiratory-triggered axial T2 weighted imaging (T2WI) was used as localizer for PRESS. Spectroscopy data was transmitted to a personal computer and was post-processed with a custom software (Saker, provided by Ning Jing, an engineer in GE Healthcare). It would be considered "technical success" if the baselines of spectra were stable and main metabolites were without overlapping and could be identified. Integral areas of choline (Cho) peak at 3.2 parts per million (ppm) and lipid (Lip) peak at 1.3 ppm were measured, and the choline to lipid (Cho/Lip) ratios were calculated. The differences of areas of Cho, Lip peak and Cho/Lip ratios before and after HIFU ablation were compared by using paired samples t test, and a P value of less than 0.05 was considered statistically significant. The technical success rate of 1H-MRS was 87.50% (42/48). Integral areas of Cho peak and Lip peak of 20 patients with satisfied spectra were measured, and the Cho/Lip ratios were calculated. The Integral area of Cho peak decreased from 34 597+/-6 802 before HIFU ablation to 6 372+/-2 466 after HIFU ablation (t = 18.02, P less than 0.01). The Integral area of Lip peak increased from 147 948+/-16 317 before HIFU ablation to 149 069+/-16 345 after HIFU ablation (t = -15.11, P less than 0.01). The Cho/Lip ratio decreased from 0.23+/-0.03 before HIFU ablation to 0.04+/-0.02 after HIFU ablation (t = 25.32, P less than 0.01). 1H-MRS could provide information of metabolites changes of primary liver cancer after HIFU ablation and could be used as a complementary sequence to other magnetic resonance sequences to evaluate all around primary liver cancer after HIFU ablation.
6.Impact of newly recommended HbA1c-based diabetes diagnostic criteria on the prevalence of diabetes and high risk individual in clinical and community population in China.
Ji LI-NONG ; Liu WEI ; Liu WEI ; Liu JING ; Dong YAN-HU ; Wang CHANG-JIANG ; Zhu DA-LONG ; Li QI-FU ; Chen LU-LU ; Xu ZHANG-RONG ; Tian HAO-MING ; Xia NING ; Zhang FAN ; Li HONG ; Liu JIE ; Shan ZHONG-YAN ; Yao XIAO-LI ; Su BEN-LI ; Zhou ZHI-GUANG ; Feng PING
Chinese Medical Journal 2010;123(8):1103-1104
7.Effectiveness of different waist circumference cut-off values in predicting metabolic syndrome prevalence and risk factors in adults in China.
Hai Cheng ZHOU ; Ya Xin LAI ; Zhong Yan SHAN ; Wei Ping JIA ; Wen Ying YANG ; Ju Ming LU ; Jian Ping WENG ; Li Nong JI ; Jie LIU ; Hao Ming TIAN ; Qiu He JI ; Da Long ZHU ; Li CHEN ; Xiao Hui GUO ; Zhi Gang ZHAO ; Qiang LI ; Zhi Guang ZHOU ; Jia Pu GE ; Guang Liang SHAN
Biomedical and Environmental Sciences 2014;27(5):325-334
OBJECTIVETo study the effectiveness of waist circumference cut-off values in predicting the prevalence of metabolic syndrome (MetS) and risk factors in adults in China.
METHODSA cross-sectional survey was condcuted in 14 provinces (autonomous region, municipality) in China. A total of 47,325 adults aged⋝20 years were selected by multistage stratified sampling, and questionnaire survey and physical and clinical examination were conducted among them. MetS was defined according to the International Diabetes Federation (IDF) criteria and modified IDF criteria.
RESULTSThe age-standardized prevalence of MetS was 24.2% (22.1% in men and 25.8% in women) and 19.5% (22.1% in men and 18.0% in women) according to the IDF criteria and modified IDF criteria respectively. The age-standardized prevalence of pre-MetS was 8.1% (8.6% in men and 7.8% in women) according to the modified IDF criteria. The prevalence of MetS was higher in urban residents than rural residents and in northern China residents than in southern China residents. The prevalence of central obesity was about 30% in both men and women according to the ethnicity-specific cut-off values of waist circumference for central obesity (90 cm for men and 85 cm for women). Multivariate regression analysis revealed no significant difference in risk factors between the two MetS definitions.
CONCLUSIONUsing both the modified IDF criteria and ethnicity-specific cut-off values of waist circumference can provide more useful information about the prevalence of MetS in China. Conclusion Using both the modified IDF criteria and ethnicity-specific cut-off values of waist circumference can provide more useful information about the prevalence of MetS in China.
Adult ; China ; epidemiology ; Cross-Sectional Studies ; Female ; Humans ; Male ; Metabolic Syndrome ; diagnosis ; epidemiology ; Middle Aged ; Obesity ; epidemiology ; Prevalence ; Risk Assessment ; Risk Factors ; Waist Circumference