1.Study on separation of sulfonamides by capillary high-performance liquid chromatography and electrochromatography.
Rui-fen YANG ; Zhi-guo SHI ; Yu-qi FENG ; Shi-lu DA
Acta Pharmaceutica Sinica 2003;38(2):129-132
AIMTo establish separation methods of five sulfonamides by using capillary high performance liquid chromatography(mu-HPLC) and electrochromatography. The effect of mobile phase varies such as methanol content, pH, buffer solution concentration and voltage on their chromatographic behavior and electroosmesis flow was investigated. Capillary electrochromatography (CEC) was compared with mu-HPLC at the same condition.
METHODSStationary phase was ODS, mobile phase was methanol and 2 mmol.L-1 H3PO4 buffer solution (pH 3.0-7.0), voltage was 0- -15 kV, flow rate was 10 microL.min-1, pressure was approximately 70 MPa and UV detection wavelength was 254 nm.
RESULTSSeparations on base line have been respectively accomplished for five sulfonamides by mu-HPLC with mobile phase of methanol-2 mmol.L-1 H3PO4 buffer solution (30:70) at pH 5.0 in 67 min, and CEC with the same mobile phase at -5 kV voltage in 25 min.
CONCLUSIONElectroosmesis flow of CEC decreased with the increase in methanol content, buffer solution concentration, increased with the increase in voltage and increase slightly with the increase in pH of mobile phase. Retention values (k) of solutes to be examined decreased with increasing methanol content of mobile phase in mu-HPLC and CEC. Retention values (k) of solutes increased slightly with increasing buffer solution concentration, decreased with increasing voltage in CEC. Trimethoprim(TMP) decreased obviously with increasing voltage in CEC. The effect of pH of mobile phase on retention values (k) was more complex. Five sulfonamides were separated at the same mobile phase condition by mu-HPLC and CEC. And separation speed of CEC was much faster than that of mu-HPLC. CEC was very fit for rapid separation of sulfonamides.
Anti-Infective Agents ; isolation & purification ; Buffers ; Chromatography, High Pressure Liquid ; methods ; Chromatography, Micellar Electrokinetic Capillary ; methods ; Hydrogen-Ion Concentration ; Sulfonamides ; isolation & purification ; Trimethoprim ; isolation & purification
3.Effects of quercetin on the learning and memory ability of neonatal rats with hypoxic-ischemic brain damage.
Jing-Jing HUANG ; Xuan LIU ; Xing-Qi WANG ; Li-Hua YANG ; Da-Shi QI ; Rui-Qin YAO
Chinese Journal of Contemporary Pediatrics 2012;14(6):454-457
OBJECTIVETo study the effects of quercetin, a flavonoid, on the learning and memory ability of 3-day-old neonatal rats with hypoxic-ischemic brain white matter damage (WMD).
METHODSSixty 3-day-old Sprague-Dawley rats were randomly divided into four groups: control, WMD model,and quercetin treatment groups (20 and 40 mg/kg). There were 15 rats in each group. Rats in the WMD model and the two quercetin treatment groups were subjected to right common carotid artery ligation followed by 2 hrs of exposure to 8% O2 to induce periventricular white matter injury. After the operation quercetin was administered daily in the two quercetin treatment groups for 6 weeks. Six weeks later, Morris water maze and open-field tests were carried out to test memory and learning ability as well as behavior and cognition.
RESULTSFrom the second day of training, escape latency in the Morris water maze test was more prolonged in the WMD model group than in the control group (P<0.01). The escape latency in the two quercetin treatment groups was shortened significantly compared with the WMD model group (P<0.05). The WMD model group crossed the original platform fewer times compared with the control and quercetin treatment groups (P<0.05). The open-field test indicated that the number of rearings increased and time spent in the centre was extended in the WMD model group compared with the control group. Compared with the WMD model group, the number of rearings was significantly reduced (P<0.05) and time spent in the centre was significantly shortened in the quercetin treatment groups (P<0.05).
CONCLUSIONSQuercetin treatment can improve memory and learning ability as well as cognitive ability in neonates with WMD, suggesting that quercetin protects against WMD resulting from hypoxia-ischemia.
Animals ; Hypoxia-Ischemia, Brain ; drug therapy ; psychology ; Learning ; drug effects ; Maze Learning ; drug effects ; Memory ; drug effects ; Quercetin ; pharmacology ; Rats ; Rats, Sprague-Dawley
4.Characteristics of cationic polymers PEI-CyD, PEI-PHPA, PEE-PHPA and PEI25kD in vitro and in vivo.
Qi YAO ; Xue JIN ; Tian-nan HU ; Qi-wen WANG ; Xun-shi WANG ; Qi-da HU ; Sang XU ; Jun ZHOU ; Gu-ping TANG
Journal of Zhejiang University. Medical sciences 2012;41(6):620-630
OBJECTIVETo study the characteristics of cationic polymers polyethylenimine-β-cyclodextrin (PEI-CyD), polyethylenimine-poly-(3-hydroxypropyl)-aspartamide (PEI-PHPA), N,N-Dimethyldipropylenetriamine-Bis(3-aminopropyl)amine-aspartamide (PEE-PHPA) in vitro and in vivo.
METHODSPEI-PHPA, PEI-CyD and PEE-PHPA were synthesized and the chemistry structure of PEI-PHPA, PEI-CyD and PEE-PHPA was confirmed by (1)H-NMR. The particle size and zeta potential of these polymers were measured, and capacity of plasmid DNA condensation was tested. The inhibition of COS-7, A549, HEK293 and C6 cells was measured by MTT assay. The transfection efficiency was determined in HEK293 cell lines. The toxicity, tissue distribution and transfection efficiency of cationic polymers were tested in vivo.
RESULTSWhen the N/P of polymers/DNA at 30, the particle sizes were close 250 nm and the zeta-potential were near 35 mv. They were able to condense DNA at N/P ratio < 5. The MTT assay showed that the IC(50) of PEE-PHPA was 21.5, 20.2, 7.30 and 37.1 μg/ml, and that of PEI25kD was 15.8, 18.3, 11.4 and 36.7 μg/ml in C6, COS-7, A549 and HEK293cell lines, respectively. The cell viability of PEI-CyD and PEI-PHPA in above cell lines was over 60%. They had high transfection efficiency in HEK293 cell lines. The LD(50) of PEI25Kd, PEI-CyD, PEI-PHPA and PEE-PHPA in vivo was 19.50, 100.4, 521.2 and 630.0, respectively by intraperitoneal (ip) injection. The contractions of these polymers were higher in kidney than in other organs and tissues.PEE-PHPA had slight effect on kidney and liver function.
CONCLUSIONPEE and PEI25kD have higher transfection efficiency and higher toxicity; while PC and PHPA-PEI have lower toxicity and higher transfection efficiency to be used as non-viral gene vector.
Cations ; Cell Line, Tumor ; Genetic Vectors ; Humans ; Polyethyleneimine ; Polymers ; Transfection ; beta-Cyclodextrins
5.Prevalence of API2-MALT1 fusion gene in gastrointestinal mucosa-associated lymphoid tissue lymphomas and diffuse large B cell lymphomas.
Bai-zhou LI ; Hong-fen LU ; Wei-qi SHENG ; Da-ren SHI
Chinese Journal of Pathology 2009;38(11):765-768
OBJECTIVETo investigate the difference of the prevalence of t(11;18)(q21;q21)/API2-MALT1 fusion gene between gastrointestinal mucosa-associated lymphoid tissue (MALT) lymphoma and diffuse large B cell lymphoma (DLBCL).
METHODSA total of 57 cases gastrointestinal MALT lymphomas (38 gastric and 19 intestinal lymphomas), 32 DLBCL (28 gastric and 4 intestinal lymphomas) and 7 cases gastric DLBCL accompanied MALT lymphoma were collected from the Cancer Hospital of Fudan University. API2-MALT1 fusion gene was detected by fluorescent in situ hybridization (FISH) using both dual fusion translocation and break apart probes.
RESULTSAmong gastrointestinal MALT lymphomas, API2-MALT1 fusion gene was found in 12 of 57 cases (21.1%, 10 gastric and 2 intestinal lymphomas). In contrast, the fusion gene was not found in all 32 DLBCL and 7 gastric DLBCL with MALT lymphoma component. There was statistical significant difference between two groups (chi(2) = 9.383, P = 0.001).
CONCLUSIONSAPI2-MALT1 fusion gene is a distinctive genetic aberration in MALT lymphomas, and is not present in DLBCL. The findings suggest that gastrointestinal tract MALT lymphomas with API2-MALT1 fusion gene may not transform into DLBCL, which may represent primary lymphoma or transformed API2-MALT1 negative MALT lymphomas.
Chromosomes, Human, Pair 11 ; Chromosomes, Human, Pair 18 ; Gastrointestinal Neoplasms ; genetics ; metabolism ; Humans ; Lymphoma, B-Cell, Marginal Zone ; genetics ; metabolism ; Lymphoma, Large B-Cell, Diffuse ; genetics ; metabolism ; Oncogene Proteins, Fusion ; genetics ; metabolism ; Translocation, Genetic
6.Management of multiple type II endoleaks detected by duplex ultrasound after endovascular abdominal aneurysm repair.
Da-Qiao GUO ; Wei-Miao LI ; Jun-Hao JIANG ; Zhen-Yu SHI ; Yu-Qi WANG ; Wei-Guo FU
Chinese Medical Journal 2012;125(15):2781-2783
We reported a case of multiple type II endoleaks detected by duplex ultrasound after endovascular abdominal aneurysm repair. The patient was undergoing warfarin therapy. Duplex ultrasound was applied as the sole surveillance method during follow-up and provided the concerned information for reintervention. The endoleaks were successfully repaired by coil embolization of the collaterals from the internal iliac artery feeding the fourth lumbar artery.
Aortic Aneurysm, Abdominal
;
diagnostic imaging
;
Female
;
Humans
;
Middle Aged
;
Ultrasonography, Doppler, Duplex
;
methods
7.Surgical treatment of abdominal aortic aneurysms in octogenarians.
Zhen-yu SHI ; Wei-guo FU ; Yu-qi WANG ; Da-qiao GUO ; Fu-zhen CHEN ; Jian-rong YE
Chinese Journal of Surgery 2005;43(7):416-419
OBJECTIVETo evaluate the open surgery as well as the endovascular treatment of abdominal aortic aneurysms (AAA) in octogenarians.
METHODSTwenty AAA cases aging from 80 to 90 in the past six years were reviewed. Open surgery on 12 patients and endovascular repair on the other 8 ones were performed.
RESULTSDuring peri-operation, there were 2 mortality from the surgical group among all 20 cases. The endovascular group underwent significantly better operational procedure and complication situation than the surgical one. Eighteen cases were followed up for 3-69 months (average months) except for 2 patients of surgical group. Both group suffered 2 late mortality. The accumulated survival rate were 6/10 in the surgical group and 6/8 in the endovascular group, respectively.
CONCLUSIONSurgical treatment in applicable for octogenarians with AAA. The endovascular repair was preferable to suitable cases.
Aged, 80 and over ; Aortic Aneurysm, Abdominal ; mortality ; surgery ; Blood Vessel Prosthesis ; Blood Vessel Prosthesis Implantation ; methods ; mortality ; Female ; Follow-Up Studies ; Humans ; Male ; Retrospective Studies ; Stents ; Survival Rate ; Treatment Outcome ; Vascular Surgical Procedures ; methods ; mortality
8.Clinical application of the disposable circumcision suture device in male circumcision.
Sheng LI ; Lei ZHANG ; Da-Wen WANG ; Sen YANG ; Hai-Qi MU ; Cun-Jin NAN ; Tie-Lin WU ; Shi-Jian ZHU ; Ying-He CHEN
National Journal of Andrology 2014;20(9):816-819
OBJECTIVETo investigate the safety and efficiency of the disposable circumcision suture device (DCSD) in the surgical treatment of phimosis and redundant prepuce.
METHODSWe randomly assigned 249 outpatients with phimosis or redundant prepuce to be treated with DCSD (n = 129) and by conventional circumcision (CC, n = 120), respectively. Then we compared the safety and efficiency of the two strategies.
RESULTSComparisons between DCSD and CC showed that the operation time was (4.02 +/- 0.69) vs (30.8 +/- 4.05) min, blood loss was (1.07 +/- 1.29) vs (8.72 +/- 2.15) ml, intraoperative pain score was 0.81 +/- 0.81 vs 2.42 +/- 1.15, 24-hour postoperative pain score was 1.84 +/- 1.02 vs 4.99 +/- 1.36, postoperative complication rate was 13. 95% (18/129) vs 9.17% (11/120), wound healing time was (13.99 +/- 9.06) vs (17.48 +/- 3.49) d, satisfaction with the penile appearance was 98.4% (127/129) vs 95% (109/120), and treatment cost was (2215.62 +/- 17.67) vs (576.47 + 15.58) Y RMB. DCSD exhibited obvious superiority over CC for shorter operation time, less blood loss, milder intraoperative pain, sooner wound healing, and better penile appearance, but it also had a higher rate of postoperative complications (P > 0.05) and involved more treatment cost than the latter (P < 0.05).
CONCLUSIONThe disposable circumcision suture device affords ideal clinical effects and therefore deserves clinical popularization.
Circumcision, Male ; instrumentation ; Disposable Equipment ; Follow-Up Studies ; Humans ; Male ; Phimosis ; surgery ; Surgical Staplers ; Treatment Outcome
9.In vitro anticoagulation monitoring of low-molecular-weight heparin.
Jian-qi WANG ; Xu-bo SHI ; Jin-gang YANG ; Da-yi HU
Chinese Medical Journal 2009;122(10):1199-1202
BACKGROUNDAlthough low-molecular-weight heparin has replaced unfractionated heparin to become the primary anticoagulation drug for treatment of acute coronary syndrome, there is no convenient bedside monitoring method. We explored the best laboratory monitoring method of low-molecular-weight heparins (enoxaparin, dalteparin, and nadroparin) by use of the Sonoclot coagulation analyzer to monitor the activated clotting time.
METHODSA total of 20 healthy volunteers were selected and 15 ml of fasting venous blood samples were collected and incubated. Four coagulants, kaolin, diatomite, glass bead, and magnetic stick, were used to determine the activated clotting time of the low-molecular-weight heparins at different in vitro anti-Xa factor concentrations. A correlation analysis was made to obtain the regression equation. The activated clotting time of the different low-molecular-weight heparins with the same anti-Xa factor concentration was monitored when the coagulant glass beads were applied.
RESULTSThe activated clotting time measured using the glass beads, diatomite, kaolin, and magnetic stick showed a linear correlation with the concentration of nadroparin (r = 0.964, 0.966, 0.970, and 0.947, respectively). The regression equation showed that the linear slopes of different coagulants were significantly different (glass beads 230.03 s/IU, diatomite 89.91 s/IU, kaolin 50.87 s/IU, magnetic stick could not be calculated). When the concentration of the anti-Xa factor was the same for different low-molecular-weight heparins, the measured activated clotting time was different after the application of the glass bead coagulant.
CONCLUSIONSThe glass bead coagulant is most feasible for monitoring the in vitro anticoagulation activity of nadroparin. The different effects of different low-molecular-weight heparins on the activated clotting time may be related to the different anti-IIa activities.
Adult ; Anticoagulants ; pharmacology ; Blood Coagulation ; drug effects ; Blood Coagulation Tests ; Coagulants ; pharmacology ; Female ; Glass ; Heparin, Low-Molecular-Weight ; pharmacology ; Humans ; Kaolin ; pharmacology ; Male ; Middle Aged ; Nadroparin ; pharmacology
10.Mismatch pair defective phenotype in hereditary nonpolyposis colorectal cancer in the Chinese.
Qi CAI ; Meng-hong SUN ; Hong-fen LU ; Xiao-li XU ; Da-liu MIN ; Tai-ming ZHANG ; Da-ren SHI
Chinese Journal of Oncology 2003;25(5):420-424
OBJECTIVETo study the protein expression pattern of DNA mismatch repair genes hMSH(2), hMLH(1) and the microsatellite instability (MSI) status in the tumor tissue from hereditary nonpolyposis colorectal cancer in the Chinese.
METHODSFifty-eight families fulfilling different clinical criteria including Amsterdam Criteria (AC) (22/24 families, 38 tumors), Japanese Criteria (JC) (12/15 families, 16 tumors) and Bethesda Guidelines (BG) (12/19 patients, 13 tumors) were studied. Monoclonal antibodies against hMSH(2), hMLH(1) proteins and a panel of microsatellite markers (5 loci) including BAT26, BAT25, D2S123, D5S346 and D17S250 were used for study.
RESULTSMSI-H was identified in all 22 (100%) AC tumors, with 81.8% (18/22) showing altered hMSH(2) or hMLH(1) expression; in 14/15 (93.8%) JC cancer, 1/1 (100%) JC adenoma, with 45.5% (5/11) showing altered hMSH(2) or hMLH(1) expression; and in 7/13 (53.8%) BG tumors, with 4/7 showing loss of hMSH(2) or hMLH(1) gene expression.
CONCLUSIONThe frequency of MSI-H and loss of mismatch repair protein are different in the families fulfilling different clinical criteria. Amsterdam Criteria and Japanese Criteria are the two most useful criterion systems for identifying mismatched repair defective tumors. However, Bethesda Guidelines should also be used for detecting more such tumors. The combination of immunohistochemical methods and microsatellite instability analysis is an effective strategy to detect the mismatch repair defective tumors. A close correlation does exist between hMSH(2), hMLH(1) protein expression pattern and MSI status.
Adaptor Proteins, Signal Transducing ; Base Pair Mismatch ; Carrier Proteins ; Colorectal Neoplasms, Hereditary Nonpolyposis ; genetics ; DNA Repair ; DNA-Binding Proteins ; Humans ; Immunohistochemistry ; Microsatellite Repeats ; MutL Protein Homolog 1 ; MutS Homolog 2 Protein ; Neoplasm Proteins ; genetics ; Nuclear Proteins ; Proto-Oncogene Proteins ; genetics