1.Clinical characteristics and therapy of cerebral arteriovenous malformations in elderly patients
Ling-Feng LAI ; Shi-Xing SU ; Da-Qun GU ; Xin ZHANG ; Xu-Ying HE ; Xi-Feng LI ; Chuan-Zhi DUAN
Chinese Journal of Neuromedicine 2013;12(3):270-274
Objective To explore the clinical characteristics and treatment of cerebral arteriovenous malformations (AVMs) in elderly patients to improve their prognoses.Methods Such clinical data as clinical manifestations,angioarchitecture features,location and therapy of 28 elderly patients (≥60 years old) with AVMs,admitted to our hospital from January 2000 to December 2011,were retrospectively analyzed.Results The elderly patients had 5.4% (28/511) morbidity of AVMs,with mean age of (62.25±3.46) years; the male patients were slightly more than the female patients.The clinical presentations included hemorrhage in 20 patients,seizure in 4,headache in 2,facial tic in 1 and tinnitus in 1.Supratentorial and infratentorial lesions were noted in 22 and 6,respectively.The maximum diameter of AVMs was smaller than 3 centimeters in 11 patients,ranged from 3 to 6 centimeters in 16,and larger than 6 centimeters in 1.Twenty-one AVMs were located in the functional areas and 7 in non-functional areas.Deep vein drainage was noted in 15,two-way drainage in 1 and superficial drainage in 11.Spetzeler-Martin grading showed grade Ⅰ in 1,grade Ⅱ in 7,grade Ⅲ in 13,grade Ⅳ in 6 and grade V in 1.After operation,endovascular embolization,27 patients had significantly improved symptoms; one patient had no effect on any treatments.Conclusion The elderly patients with cAVMs have low morbidity with hemorrhage as its most common symptom; and the lesions mostly locate in the supratentorial region; active intervention therapy (resection,endovascular embolization and radiotherapy)can obviously improve the prognosis and quality of lives.
2.Apalutamide for patients with metastatic castrationsensitive prostate cancer in East Asia: a subgroup analysis of the TITAN trial.
Byung Ha CHUNG ; Jian HUANG ; Zhang-Qun YE ; Da-Lin HE ; Hirotsugu UEMURA ; Gaku ARAI ; Choung Soo KIM ; Yuan-Yuan ZHANG ; Yusoke KOROKI ; SuYeon JEONG ; Suneel MUNDLE ; Spyros TRIANTOS ; Sharon MCCARTHY ; Kim N CHI ; Ding-Wei YE
Asian Journal of Andrology 2022;24(2):161-166
Ethnicity might be associated with treatment outcomes in advanced prostate cancer. This study aimed to evaluate the efficacy and safety of androgen deprivation therapy (ADT) combined with apalutamide in East Asians with metastatic castration-sensitive prostate cancer (mCSPC). The original phase 3 Targeted Investigational Treatment Analysis of Novel Anti-androgen (TITAN) trial was conducted at 260 sites in 23 countries. This subgroup analysis included patients enrolled in 62 participating centers in China, Japan, and Korea. Radiographic progression-free survival (PFS), time to prostate-specific antigen (PSA) progression, and PSA changes from baseline were compared between groups in the East Asian population. The intent-to-treat East Asian population included 111 and 110 participants in the apalutamide and placebo groups, respectively. The 24-month radiographic PFS rates were 76.1% and 52.3% in the apalutamide and placebo groups, respectively (apalutamide vs placebo: hazard ratio [HR] = 0.506; 95% confidence interval [CI], 0.302-0.849; P = 0.009). Median time to PSA progression was more favorable with apalutamide than placebo (HR = 0.210; 95% CI, 0.124-0.357; P < 0.001). Median maximum percentages of PSA decline from baseline were 99.0% and 73.9% in the apalutamide and placebo groups, respectively. The most common adverse event (AE) was rash in the apalutamide group, with a higher rate than that in the placebo group (37.3% vs 9.1%). The most common grade 3 or 4 AEs were rash (12 [10.9%]) and hypertension (12 [10.9%]) for apalutamide. The efficacy and safety of apalutamide in the East Asian subgroup of the TITAN trial are consistent with the global results.
Androgen Antagonists/adverse effects*
;
Exanthema/chemically induced*
;
Far East
;
Humans
;
Male
;
Prostate-Specific Antigen
;
Prostatic Neoplasms, Castration-Resistant/pathology*
;
Thiohydantoins/adverse effects*
3.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve