1.ERRATUM: Spelling Correction. Suppressive effects of long-term treatment with inhaled steroids on hypothalamic-pituitary-adrenal axis in asthma.
Da Woon SIM ; Inseon S CHOI ; Seung Hun KIM
Allergy, Asthma & Respiratory Disease 2014;2(5):398-398
On page 289 of this paper, the x-axis title in Fig. 3A has been incorrectly spelled.
2.ERRATUM: Table Correction. Suppressive effects of long-term treatment with inhaled steroids on hypothalamic-pituitary-adrenal axis in asthma.
Da Woon SIM ; Inseon S CHOI ; Seung Hun KIM
Allergy, Asthma & Respiratory Disease 2015;3(1):90-91
Some parts of Tables 1 and 2 in this paper was described incorrectly.
3.Suppressive effects of long-term treatment with inhaled steroids on hypothalamic-pituitary-adrenal axis in asthma.
Da Woon SIM ; Inseon S CHOI ; Seung Hun KIM
Allergy, Asthma & Respiratory Disease 2014;2(4):285-292
PURPOSE: Long-term treatment with inhaled steroids (ICS), especially fluticasone that developed lately, may suppress the hypothalamic-pituitary-adrenal (HPA) axis. This study investigated the relationship between ICS use and HPA axis suppression in asthmatics under ICS treatment for average 4.5 years. METHODS: The medical records of 129 adult asthmatics who received ICS treatment for 6 months or more and underwent a corticotropin stimulation test from January 2005 to August 2013 were retrospectively reviewed. RESULTS: The patients received ICS only (n=87) were found to have an abnormal response to the corticotropin test in as high as 32.2%, and those received ICS in combination with oral steroids (n=42) had a significantly higher prevalence of the response (71.4%, P<0.001). Abnormal responses to corticotropin occurred depending on ICS daily doses (low, n=8, 12.5%; medium, n=19, 36.8%; high, n=102, 49.0%; chi2=4.384, P=0.036). Among the subjects received ICS only, nasal steroid doses (P=0.016) but not ICS doses (P=0.159) were significantly higher in those with abnormal responses than the others. Among all the subjects, oral steroid use (odds ratio [OR], 4.27; 95% confidence interval [CI], 2.35-11.80; P<0.001) and nasal steroid dose (OR, 1.02; 95% CI, 1.00-1.04; P=0.015) were significant risk factors for HPA axis suppression. CONCLUSION: One-third of asthmatics under long-term treatment with ICS showed a suppression of the HPA axis in a dose-dependent manner. Oral or nasal steroid use may be a risk factor for the suppression. However, since our results may have been overestimated due to subject selection bias, further prospective case-control studies are warranted.
Adrenal Glands
;
Adrenocorticotropic Hormone
;
Adult
;
Asthma*
;
Axis, Cervical Vertebra*
;
Case-Control Studies
;
Humans
;
Medical Records
;
Prevalence
;
Retrospective Studies
;
Risk Factors
;
Selection Bias
;
Steroids*
;
Fluticasone
4.Biomarkers of adult asthma and personalized medicine.
Allergy, Asthma & Respiratory Disease 2016;4(1):4-13
The concept of personalized medicine for disease diagnosis, treatment, and management, considering individual variability, including susceptibility, clinical manifestations, and drug responsiveness, is a global emerging trend in medicine, which is also inevitable. However, clinical applications of personalized medicine in the real-world practice have been limited to certain cancers so far. Furthermore, this new concept to the diagnosis and treatment of adult asthma has not been applied to clinical use. Asthma is a multifactorial and heterogeneous disease. It seems to encompass a broad spectrum of clinical manifestations with different underlying pathophysiological mechanisms. Thus, it is not easy to categorize by their clinical features alone. Endotypical categorization that considering specific pathophysiological mechanisms will be more helpful in applying the concept of personalized medicine. The success of personalized medicine depends on patient selection for precise prescription of asthma medications. In the recent years, many investigators and physicians have devoted a lot of effort to the discovery of reliable biomarkers in asthmatic patients, which will be able to actualize the personalized medicine in near future. Despite such great efforts toward investigation of good biomarkers, few things have turned out to be practical in the clinic. Easily interpretable biomarkers of asthma are necessary to assess early detection, determination of treatment, prognosis prediction, and monitoring of exacerbation. Herein, we review recent studies regarding disease classifications and biomarkers of asthma.
Adult*
;
Asthma*
;
Biomarkers*
;
Classification
;
Diagnosis
;
Humans
;
Precision Medicine*
;
Patient Selection
;
Phenotype
;
Prescriptions
;
Prognosis
;
Research Personnel
10.A Case of Type 2 Hereditary Angioedema With SERPING1 Mutation.
Da Woon SIM ; Kyung Hee PARK ; Jae Hyun LEE ; Jung Won PARK
Allergy, Asthma & Immunology Research 2017;9(1):96-98
Hereditary angioedema is a disease of congenital deficiency or functional defect in the C1 esterase inhibitor (C1-INH) consequent to mutation in the SERPING1 gene, which encodes C1-INH. This disease manifests as recurrent, non-pitting, non-pruritic subcutaneous, or submucosal edema as well as an erythematous rash in some cases. These symptoms result from the uncontrolled localized production of bradykinin. The most commonly affected sites are the extremities, face, gastrointestinal tract, and respiratory system. When the respiratory system is affected by hereditary angioedema, swelling of the airway can restrict breathing and lead to life-threatening obstruction. Herein, we report a case of a 24-year-old woman with type 2 hereditary angioedema who presented with recurrent episodic abdominal pain and swelling of the extremities. She had no family history of angioedema. Although her C4 level was markedly decreased (3.40 mg/dL; normal range: 10-40 mg/dL), she presented with a very high C1-INH level (81.0 mg/dL; normal range: 21.0-39.0 mg/dL) and abnormally low C1-INH activity (less than 25%; normal range: 70%-130%). The SERPING1 gene mutation was confirmed in this patient. She was treated with prophylactic tranexamic acid, as needed, and subsequently reported fewer and less severe episodes. To our knowledge, this is the first reported case of type 2 hereditary angioedema in Korea that was consequent to SERPING1 mutation and involved a significantly elevated level of C1-INH as well as a low level of C1-INH activity.
Abdominal Pain
;
Angioedema
;
Angioedemas, Hereditary*
;
Bradykinin
;
Complement C1 Inhibitor Protein
;
Edema
;
Exanthema
;
Extremities
;
Female
;
Gastrointestinal Tract
;
Humans
;
Korea
;
Reference Values
;
Respiration
;
Respiratory System
;
Tranexamic Acid
;
Young Adult