1.Computed tomographic measurement of calvarial size in normal pediatric subjects.
YH LEE ; J H SUH ; D I KIM ; T S CHUNG ; C J KO ; C U CHOI
Journal of the Korean Radiological Society 1989;25(6):1024-1031
Growth Patterns of cranium measured directly as head circumference have been well documented. With the recent progress in CT, it is easy to measure the size and cross sectional area of the structure. The author chose themidvnetricular level of brain CT scan and measured the product of maximum anteroposterior and lateral dimension and cross sectional area. The age of infants ans children was 0 to 2 years old. The author obtained the following results through statistical analysis; 1. The maximum anteroposterior dimension and the cross sectional area were obtained through the computerized program of CT scanner. Using these measurements, monthly growth curve was obtained and which shows accelarated growth in the initial 12 months especially during the first four months, and followd by reduced rate of growth in the next 12 months. 2. Comparing the size of the calvarium between sexed,females' were somewhat larger than males', but there was no statistical significance. 3. Comparing the crosssectional area with the head circumference, high correlation was seen(correlation coefficient=0.96). Similarelationship was also seen between the product of cranial linear dimensions and the head circumference(correlationcoefficient=0.93). Also statistically significant relationship was noted between the cross sectional area and theproduct of the cranial linear dimensions(correlation coefficient=0.97). 4. Using the cross sectional area and theproduct of cranial linear dimenstions, monthly average value and the 95% significant range were obtained which canbe used as indices for the growth and development of cranium. Of these, the product of cranial linear dimensionscan eadily be measured by brain CT images, which may be useful on practical basis.
Brain
;
Child
;
Growth and Development
;
Head
;
Humans
;
Infant
;
Skull
;
Tomography, X-Ray Computed
2.Assessments of myocardial perfusion in human using stress intravenous PESDA myocardial contrast echocardiography and Pulse Inversion Harmonic Imaging: A Comparison study with Tc-99m sestamibi SPECT.
Ki Hwan KWON ; N CHUNG ; J W HA ; S J RIM ; H J KIM ; K J CHANG ; B K LEE ; W B PYUN ; I J KIM ; D K KIM ; D H CHOI ; Y S JANG ; J D LEE ; S Y CHO ; S S KIM
Korean Circulation Journal 2000;30(7):793-802
OBJECTIVE: The object of this study was to assess the accuracy of dipyridamole stress intravenous (IV) myocardial contrast echocardiography (MCE) using pulse inversion harmonic imaging and PESDA in the detection of perfusion defect in the patients with coronary artery disease in comparison with dipyridamole stress Tc-99m sestamibi SPECT. METHODS: Total 46 patients (29 males, mean age 64 years old) were consecutively enrolled. Patients with prior myocardial infarction were excluded. MCE and Tc-99m sestamibi SPECT were performed at the same day during rest and after 0.56 or 0.84mg/Kg dipyridamole infusion. Continuous IV infusion of PESDA (2-5 mL/min) was administered while obtaining triggered (1:1) end-systolic apical 2, 4 chamber and long axis views. Tc-99m sestamibi was injected 3 minutes after dipyridamole. Tc-99m sestamibi SPECT images were obtained one hour later. Coronary angiography was followed within two days in all patients. Tc-99m sestamibi SPECT images were matched to the sixteen segments of left ventricle according to American Society of Echocardiography for segmental comparison. Both images were analyzed visually. Results Using coronary angiography as the standard, MCE showed overall sensitivity of 70.7%, specificity of 95.8%, positive predictive value (PPV) of 87.8% and negative predictive value (NPV) of 88.5% in the detection of coronary atherosclerosis (70% stenosis). Tc-99m sestamibi SPECT showed sensitivity of 75.6%, specificity of 98.9%, PPV of 96.8% and NPV of 90.6%. The overall concordance rate between MCE and Tc-99m sestamibi SPECT for the detection of perfusion defects was 86.9% (Cohen's kappa value 0.63) according to the coronary territory and 86.8% (Cohen's kappa value 0.55) according to segmental analysis. CONCLUSION: Dipyridamole stress IV MCE using pulse inversion harmonic imaging and PESDA is feasible and comparable to Tc-99m sestamibi SPECT in identifying significant coronary stenosis and inducible myocardial perfusion defects in the patients with coronary artery disease. MCE using pulse inversion harmonic imaging seems to be a promising modality for assessing myocardial perfusion in the patients with suspected coronary artery disease.
Axis, Cervical Vertebra
;
Coronary Angiography
;
Coronary Artery Disease
;
Coronary Stenosis
;
Dipyridamole
;
Echocardiography*
;
Heart Ventricles
;
Humans*
;
Male
;
Myocardial Infarction
;
Perfusion*
;
Sensitivity and Specificity
;
Tomography, Emission-Computed, Single-Photon*