OBJECTIVE: To establish a method for the determination of nitrofurazone in nitrofurazone and zinc oxide liniment. METHODS: The content of nitrofurazone was determined by UV spectrophotometry. The solvent was water and the wavelength was 375nm. RESULTS: There was good linear relationship within the concentration range of 1.05~12.60?g?mL-1(r=0.999 8). The average recovery was 100.9%,RSD=0.07%. CONCLUSION: The method was sensitive, accurate, reliable, reproducible, and suitable for quality control of nitrofurazone in nitrofurazone and zinc oxide liniment.