1.Corrosion Characteristics Between Implant Fixture And Abutment Screw.
Su Jin KEE ; Hyeog Sin KWEON ; Han Chul CHOE
The Journal of Korean Academy of Prosthodontics 2000;38(1):85-97
The purpose of this study was to compare the corrosion characteristics between implant fixture and two types of abutment screw; gold screw, titanium screw. The anodic polarization behavior, the galvanic corrosion behavior, and the crevice corrosion behavior of prepared samples were investigated using potentiostat and scanning electron microscope. The results were as follows : 1. Anodic polarization behavior of samples: The primary passivation potential of implant fixture was -420mV, implant abutment was -560mV, titanium screw was -370mV and gold screw was -230mV. All samples were shown to have a high corrosion potential and good formation of passive film. The critical passive current density of gold screw was higher than of other samples and the sample of gold screw showed a unstable passive film formation at passive region. 2. Galvanic corrosion behavior of samples: Contact current density between implant fixture and titanium screw showed 8.023x 10-5C/cm2. Contact current density between implant fixture and gold screw showed 5.142x 10-5C/cm2. 3. Crevice corrosion behavior of samples : The crevice corrosion resistance of sample using titanium screw was higher than that of sample using gold screw, and a severe corrosion morphologies were observed at the fixture-screw interface by the scanning electron microscope.
Corrosion*
;
Titanium
2.An electrochemical study on the corrosion resistance of the various implant metals.
The Journal of Korean Academy of Prosthodontics 1993;31(3):423-446
No abstract available.
Corrosion*
;
Metals*
3.Scanning electron microscopic findings of the rat femoral head vascular architecture using a corrosion casting.
Chang Soo KANG ; Woo Yul LEE ; Kwan Kyu PARK
The Journal of the Korean Orthopaedic Association 1993;28(5):1866-1873
No abstract available.
Animals
;
Corrosion Casting*
;
Corrosion*
;
Head*
;
Rats*
4.A STUDY OF INTERFACE AND CORROSION BEHAVIOR BETWEEN IMPLANT ABUTMENT AND CASTING GOLD ALLOY.
Mee Kyoung SON ; Jang Seon MA ; Chae Heon CHUNG
The Journal of Korean Academy of Prosthodontics 1999;37(5):672-686
The purpose of this study was to compare the casting problem and corrosion behavior in two types of HL Hexed abutments of the Steri-Oss system : gold/plastic coping and gold coping. The anodic Polarization behavior, the galvanic corrosion between abutments and Type III gold alloys, before and after casting were analyzed, and the crevice corrosion of casting samples was analyzed with the CPPT test and the SEM. The results are as follows ; 1. Anodic polarization behavior of samples ; Before casting, gold/plastic coping and gold coping was shown to have a similar corrosion patterns. TypeIII casting gold alloy was shown to have a lower corrosion potential and passivation film. Corrosion potential of the case of gold/plastic coping after casting was higher than that of gold coping, but the region of passivation film for gold/plastic coping was smaller than that of gold coping. 2. Galvanic corrosion behavior of samples ; Contact current density between casting gold alloys and gold/plastic before casting was higher than that between gold coping and casting gold alloy. Galvanic corrosion of samples after casting was shown to have similar contact current density. 3. Crevice corrosion behavior of samples ; Crevice corrosion resistance of casting sample using gold coping was lower than that of casting sample using gold/plastic coping, and a severe corrosion pattern was observed at the abutment-casting gold alloy interface by the SEM.
Alloys*
;
Corrosion*
;
Gold Alloys
5.Detorque force and surface change of coated abutment screw after repeated closing and opening.
Jong Suk JANG ; Hee Jung KIM ; Chae Heon CHUNG
The Journal of Korean Academy of Prosthodontics 2008;46(5):500-510
STATEMENT OF PROBLEM: Recently researches about WC/C (Tungsten Carbide/Carbon) or TiN (Titanium Nitride) coating on abutment screws are going on. It decreases friction coefficient, resistance against corrosion and withdrawal of physical fragility when the coating is applied to the metal surfaces. It is reported that coated abutment screws improved abrasion, adaptability and detorque force. PURPOSE: This study is about the effects of coated abutment screws on loosening of screw and for the purpose of solving the loosening phenomenon of abutment screws which is clinical problem. MATERIAL AND METHODS: Detorque force and surface changes are compared when 10 times of repeated closing and opening are applied to both uncoated titanium abutment screws (Group A) and coated abutment screws with WC/C (Group B) and TiN (Group C). Each group was made up of 10 abutment screws. RESULTS: 1. Before repeated closing and opening, Somewhat rough surface with regular direction was observed in Group A. Coated granules were observed in group B and group C and overall coated layer appeared in regular and smooth form. 2. Before repeated closing and opening, The coated surface showed bigger and thicker size of coated granules in Group C than Group B. 3. After repeated closing and opening, abrasion and deformation of abutment screw surface was observed in Group A and Group B. Exfoliation phenomenon was observed in Group B. 4. Group A showed biggest range of decrease when the weight changes of abutment screws were measured before and after repeated closing and opening. Group C showed less weight changes than Group B but there was no statistical difference between two groups. 5. Group B and Group C showed higher average detorque force than Group A and there was statistical difference. 6. Group A showed more prominent decrease tendency of average detorque force than Group B and Group C. CONCLUSION: Coated abutment screws with WC/C or TiN did not show prominent surface changes than uncoated titanium abutment screws even though they were repeatedly used. And they showed excellent resistance against friction and high detorque force. Thus it is considered that adaptation of WC/C or TiN coating on abutment screws will improve the screw loosening problem.
Corrosion
;
Friction
;
Tin
;
Titanium
6.Comparative Studies of the Renal Vasculature of the Human and the Experimental Animals by Renal Microangiography and Corrosion Casts.
Kyung Tak SUNG ; Jong Byung YOON
Korean Journal of Urology 1990;31(4):471-480
No abstract available.
Animals*
;
Corrosion*
;
Humans*
7.Bench-top Comparison of Physical Properties of 4 Commercially-Available Self-Expanding Intracranial Stents.
Su Hee CHO ; Won Il JO ; Ye Eun JO ; Ku Hyun YANG ; Jung Cheol PARK ; Deok Hee LEE
Neurointervention 2017;12(1):31-39
PURPOSE: To better understand the performance of four commercially available neurovascular stents in intracranial aneurysm embolization, the stents were compared in terms of their basic morphological and mechanical properties. MATERIALS AND METHODS: Four different types of stents that are currently being used for cerebral aneurysm embolization were prepared (two stents per type). Two were laser-cut stents (Neuroform and Enterprise) and two were braided from a single nitinol wire (LEO and LVIS stents). All were subjected to quantitative measurements of stent size, pore density, metal coverage, the force needed to load, push, and deploy the stent, radial force on deployment, surface roughness, and corrosion resistance. RESULTS: Compared to their nominal diameters, all stents had greater diameters after deployment. The length generally decreased after deployment. This was particularly marked in the braided stents. The braided stents also had higher pore densities than the laser-cut stents. Metal coverage was highest in the LEO stent (14%) and lowest in the Enterprise stent (5%). The LIVS stent had the highest microcatheter loading force (81.5 gf). The LEO stent had the highest passage force (55.0 gf) and deployment force (78.9 gf). The LVIS and LEO stents had the highest perpendicular (37.1 gf) and circumferential (178.4 gf) radial forces, respectively. The Enterprise stent had the roughest stent wire, followed by the LVIS, LEO, and Neuroform stents. CONCLUSION: The four neurovascular stent types differed in terms of morphological and physical characteristics. An understanding of this diversity may help to decide which stent is most suitable for specific clinical situations.
Corrosion
;
Intracranial Aneurysm
;
Stents*
8.A scanning electron microscopic study on the corrosion resistance of chemically and thermally recycled metal brackets.
Korean Journal of Orthodontics 1989;19(2):85-93
The purpose of this study was to evalute the corrosion resistance of chemically and thermally recycled metal brackets. In vivo, two types of recycled metal brackets and new brackets were directly bonded for 1 year, and then the microstructure of bracket surface was examined by S.E.M. (J.S.M.-840 Scanning Electron Microscope, Japan). The following results were obtained. 1) The microstructure of new and chemically recycled metal bracket surfaces showed regular structure without island formation and recrystallization; and after 1 year, the same appearance except some scratches. 2) The microstructure of thermally recycled metal bracket surfaces showed a beginning of island formation and recrystallization by annealing, and after 1 year, a typical corrosive appearance, completely island formation with some metal grains by recrystallization. 3) Chemically recycled metal brackets showed better corrosion resistance than thermally recycled metal brackets.
Edible Grain
;
Corrosion*
9.A Study for The Nature of Pigmentation Adjacent to Titanium Miniplate Osteosynthesis.
Dong Whan WEON ; Hyun Ho JOO ; Sang Hwy LEE ; Il Hyun KIM
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2001;27(1):25-31
The titanium miniplate osteosynthesis system has been used for fixation of bone fragments in the maxillofacial areas due to easy manipulation and even has been proposed for unnecessity of miniplate removal because of the biocompatibility and the corrosion resistance. But recently, there have been some suggestions for its removal, on the basis of findings that there have been pigmentations around the adjacent tissues during miniplate removal procedure and they are the depositions of metal particles. Purposes of this study are to ascertain the presence and nature of pigmentation observed within tissues adjacent to titanium miniplate, and to suggest possible causes of it. We could observe the black pigmentation during miniplate removal procedure for recent about 1.5 year. Pigmented tissues were stained with hematoxylin-eosin(H-E) for light microscophic(LM) examination to investigate the black pigmentations and the histomorphology around them. The scanning electron microscopy(SEM) with energy dispersive X-ray(EDX) analysis was used to examine the ultrastructural nature of pigmentations. Many metal particles with variable sizes and shapes were seen in the connective tissue by SEM and were identified as titanium by EDX.
Connective Tissue
;
Corrosion
;
Pigmentation*
;
Titanium*
10.A study on surface alteration of implant screws after function.
Myung Ju HAN ; Chae Heon CHUNG ; Han Cheol CHOI
The Journal of Korean Academy of Prosthodontics 2002;40(3):275-286
STATEMETN OF PROBLEM: Surface alteration of the implant screws after function may be asso-ciated with mechanical failure. Theses metal fatigue appears to be the most common cause of structural failure. PURPOSE: The purpose of this study was to evaluate surface alteration of the implant screws after function through the examination of used and unused implant screws in SEM(scanningelectron microscope). MATERIAL AND METHODS: In this study, abutment screws(Steri-oss, 3i), gold retaining screw(3i) and titanium retaining screw(3i) were retrieved from patients. New, unused abutment and retain-ing screws were prepared for control group. Each of the old, used screws was retrieved with a screwdriver. And retrieved implant complex of Steri-oss system was prepared for this study. Then, SEM investigation and EDS analysis of abutment and retaining screws were per-formed. And SEM investigation of cross-sectioned sample of retrieved implant complex was performed. RESULTS: In the case of new, unused implant screws, as maunfactured circumferential grooves are regularly examined and screw thread are sharply remained. Before ultrasonic cleans-ing of old, used implant screw, a lot of accumulation and corrosion products were existed. After ultrasonic cleansing of old, used implant screws, circumferential grooves as examined before function were randomly deepened and scratches increased. Also, dull screw thread was examined. More surface alterations after function were examined in titanium screw than gold screw. And more surface alteration was examined when retrieved with driver than retrieved without driver. CONCLUSIONS: These surface alteration after function may result in the screw instability. Regularly cleansing and exchange of screws was recommended. We recommend the use of gold screw rather than titanium screw, and careful manipulation of the driver.
Corrosion
;
Fatigue
;
Humans
;
Titanium
;
Ultrasonics