1.Application of Targeted Coronary Angiography in the Diagnosis of Sudden Cardiac Death.
Xin ZHAO ; Zhi-Ming CHEN ; Wen-Yun LIU ; Bo WANG ; Hong-Yang LI ; Li-Yao YANG ; Yan TENG ; Li-Jun WANG ; Yan-Bin GAO ; Wei-Long CHEN ; Lei ZHANG
Journal of Forensic Medicine 2023;39(6):542-548
OBJECTIVES:
To diagnose coronary artery stenosis by using the postmortem computed tomography angiography (PMCTA), and to explore the diagnostic value of PMCTA in sudden cardiac death.
METHODS:
Six death cases were selected, and the contrast medium iohexol was injected under high pressure through femoral artery approach with 5F pigtail catheter to obtain coronary image data and then the data was analyzed. The results of targeted coronary imaging and coronary artery calcium score (CaS) were compared with the results of conventional autopsy and histopathological examination.
RESULTS:
The autopsy and histopathological examination of cases with coronary artery stenosis obtained similar results in targeted coronary angiography, with a diagnostic concordance rate of 83.3%. Targeted coronary angiography could effectively show coronary artery diseases, and the CaS was consistent with the results of conventional autopsy and histopathological examination.
CONCLUSIONS
Targeted coronary angiography can be used as an effective auxiliary method for conventional autopsy in cases of sudden cardiac death.
Humans
;
Computed Tomography Angiography/methods*
;
Coronary Angiography/methods*
;
Coronary Artery Disease/diagnostic imaging*
;
Coronary Stenosis/diagnostic imaging*
;
Death, Sudden, Cardiac/pathology*
2.Predictive Value of Pancreatic Steatosis for Severity of Coronary Atherosclerosis in Patients with Type 2 Diabetes Mellitus.
Peng-Tao SUN ; Xue-Chao DU ; Ruo-Dun WANG ; Ying SUN ; Xiao-Li SUN ; Tong ZHAO ; Hai-Liang WEI ; Ren-Gui WANG
Acta Academiae Medicinae Sinicae 2020;42(2):172-177
To investigate the association of pancreatic steatosis with coronary atherosclerosis in patients with type 2 diabetes mellitus (T2DM). Patients with T2DM who underwent coronary computed tomography angiography(CCTA)in our center due to chest pain were enrolled from January 2016 to February 2019. According to the CCTA findings,patients were divided into normal group,mild-to-moderate coronary atherosclerosis group and severe coronary atherosclerosis group. CT attenuation of pancreas and spleen was measured on abdominal non-enhanced CT,and the CT attenuation indexes including the difference between pancreatic and splenic attenuation (P-S) and the ratio of pancreas-to-spleen attenuation (P/S) were calculated. Analysis of variance or Kruskal-Wallis rank test were used to assess differences among each group. Logistic regression analysis was used to analyze the risk factors of severe coronary stenosis. The accuracy of P/S in predicting severe coronary artery stenosis was assessed by receiver operator characteristic (ROC) curve analysis. A total of 173 consecutive T2DM patients were enrolled. These patients included 27 patients with normal coronary artery (15.6%),124 patients with mild to moderate stenosis (71.7%),and 22 patients with severe stenosis (12.7%). There were significant differences in CT attenuation of pancreas (=11.543,=0.003),P-S (=11.152,=0.004) and P/S (=11.327,=0.004) among normal coronary artery group,mild and moderate stenosis group,and severe stenosis group. The CT attenuation of pancreatic head,body,and tail significantly differed in patients with coronary artery stenosis (=14.737,=0.001). After adjusting for confounding factors,multiple Logistic regression showed that P/S (=0.062,95%=0.008-0.487,=0.008) was still significantly associated with the severe coronary artery stenosis. The area under the ROC curve of P/S for the diagnosis of severe coronary artery stenosis was 0.701,and the optimal cutoff point was 0.660. CT attenuation of pancreas and CT attenuation indexes are associated with the severity of coronary stenosis in T2DM patients,suggesting that pancreatic steatosis may be used as one of the indicators for predicting severe coronary artery stenosis.
Coronary Angiography
;
Coronary Artery Disease
;
complications
;
Coronary Stenosis
;
Diabetes Mellitus, Type 2
;
complications
;
Humans
;
Pancreas
;
pathology
;
Predictive Value of Tests
3.Correlation between Coronary Artery Tortuosity and Stenosis in Patients with Myocardial Bridge.
Dong Xu CAI ; Jin Xi SHI ; Xin Bin ZHAO ; Zhi QI
Acta Academiae Medicinae Sinicae 2020;42(6):766-770
Objective To analyze the correlation between tortuosity and stenosis in patients with myocardial bridge(MB)on the left anterior descending artery(LAD). Methods Data of patients with MB on the LAD,which was discovered by coronary computed tomography angiography(CCTA),in the Affiliated Hospital of North China University of Science and Technology from October 2015 to December 2018 were retrospectively analyzed.Among them 278 patients with tortuosity on LAD and 278 patients without tortuosity were selected.The clinical charateristics(age,gender,hypertension,hyperlipidemia,diabetes,smoking history,and family history)as well as the incidence and severity of stenosis of LAD were recorded and compared. Results The incidence of coronary artery stenosis in the non-tortuosity group(57.6%)was significantly lower than that in the tortuosity group(71.9%)($\bar{χ}$=12.608,
China
;
Constriction, Pathologic
;
Coronary Angiography
;
Coronary Stenosis/epidemiology*
;
Coronary Vessels/diagnostic imaging*
;
Humans
;
Myocardial Bridging/pathology*
;
Retrospective Studies
4.Prognosis of patients with vulnerable plaques indicated by coronary CT angiography.
Zhanlu LI ; He HUANG ; Wenbin ZHANG ; Min WANG ; Guosheng FU
Journal of Zhejiang University. Medical sciences 2020;49(1):76-81
OBJECTIVE:
To investigate the prognosis of patients with vulnerable plaque indicated by coronary CT angiography (CCTA).
METHODS:
Totally 1963 patients underwent CCTA from February 2nd 2015 to September 13th 2015, and 2728 coronary borderline lesions (stenosis of 50%-70%) were detected. Among them 804 patients had vulnerable plaques and 1159 patients had stable plaques. The primary endpoint was major cardiac adverse events (MACE), including cardiac death, acute myocardial infarction and target lesion revascularization.
RESULTS:
Patients were followed up for a mean follow-up of 27.4±2.3 months. The incidence of MACE in the vulnerable plaque group was significantly higher than that in the stable plaque group (10.8%vs 2.3%, < 0.01). After adjusting for age, gender, smoking, hypertension, diabetes, hyperlipidemia, the MACE hazard ratio () in the vulnerable plaque group was 5.022 (95% :3.254-7.751, < 0.01).Subgroup analysis showed that in the vulnerable plaque group, the incidence of MACE in patients taking antiplatelet and statin ≤3 months and those taking antiplatelet and statin > 3 months was 17.0%and 5.8%, respectively (=3.149, 95% :1.987-4.992, < 0.01); but the difference did not seen in stable plaque group (=1.721, 95% :0.798-3.712, >0.05).
CONCLUSIONS
This study confirmed the risk of MACE in patients with vulnerable plaque detected by CCTA and the drug treatment may reduce the risk for patients with vulnerable plaque.
Computed Tomography Angiography
;
Coronary Angiography
;
Coronary Artery Disease
;
diagnostic imaging
;
Coronary Stenosis
;
diagnostic imaging
;
Humans
;
Infant
;
Plaque, Atherosclerotic
;
diagnostic imaging
;
pathology
;
Prognosis
;
Risk Factors
5.Correlation of lipoprotein(a) with clinical stability and severity of coronary artery lesions in patients with coronary artery disease.
Yusheng MA ; Jiahuan RAO ; Jieni LONG ; Lilong LIN ; Jichen LIU ; Zhigang GUO
Journal of Southern Medical University 2019;39(2):235-240
OBJECTIVE:
To analyze the correlation of lipoprotein(a) [Lp(a)] with the clinical stability and severity of coronary artery stenosis in patients with coronary artery disease (CAD).
METHODS:
A total of 531 patients undergoing coronary angiography in Nanfang Hospital between January, 2013 and December, 2016 were enrolled in this study. At the cutoff Lp(a) concentration of 300 mg/L, the patients were divided into high Lp(a) group (=191) and low Lp(a) group (=340). In each group, the patients with an established diagnosis of CAD based on coronary angiography findings were further divided into stable angina pectoris (SAP) group and acute coronary syndrome (ACS) group. The correlation between the severity of coronary artery stenosis and Lp(a) was evaluated.
RESULTS:
The patients in high and low Lp(a) groups showed no significant differences in age, gender, body mass index, smoking status, hypertension, or diabetes (>0.05). Multivariate logistic regression analysis revealed that age, gender, and serum levels of low-density lipoprotein cholesterol (LDL-C) and Lp(a) were independent risk factors for CAD in these patients. A high Lp(a) level was associated with an increased risk of CAD (OR=2.443, 95%CI: 1.205-4.951, =0.013). The patients with a high Lp(a) level were at a significantly higher risk of CAD than those with a low Lp(a) level irrespective of a low or high level of LDL-C (=0.006 and 0.020). In the patients with CAD, the ACS group had a significantly higher Lp(a) level than the SAP group ( < 0.001); the proportion of the patients with high Gensini scores was significantly greater in high Lp(a) group than in low Lp(a) group (17.3% vs 5.6%, =0.026), and a linear relationship was found between Lp(a) level and Gensini score (R=0.130, =0.006).
CONCLUSIONS
Serum level of Lp(a) is an independent risk factor for CAD, and an increased Lp(a) is the residual risk for CAD. In patients with CAD, a high Lp(a) level is associated with the clinical instability and severity of coronary artery stenosis.
Acute Coronary Syndrome
;
blood
;
Angina Pectoris
;
blood
;
Cholesterol, LDL
;
blood
;
Coronary Angiography
;
Coronary Artery Disease
;
blood
;
classification
;
Coronary Stenosis
;
blood
;
pathology
;
Humans
;
Lipoprotein(a)
;
blood
;
Regression Analysis
;
Risk Factors
;
Severity of Illness Index
6.Predicting asymptomatic coronary artery stenosis by aortic arch plaque in acute ischemic cerebrovascular disease: beyond the cervicocephalic atherosclerosis?
Xin MA ; Qi KONG ; Chen WANG ; Gary RAJAH ; Yu-Chuan DING ; Yu-Ren ZHANG ; Xiang-Ying DU
Chinese Medical Journal 2019;132(8):905-913
BACKGROUND:
Asymptomatic coronary artery stenosis (ACAS) ≥50% is common in patients with acute ischemic cerebrovascular disease (AICVD), which portends a poor cardiovascular and cerebrovascular prognosis. Identifying ACAS ≥50% early may optimize the clinical management and improve the outcomes of these high-risk AICVD patients. This study aimed to investigate whether aortic arch plaque (AAP), an early atherosclerotic manifestation of brain blood-supplying arteries, could be a predictor for ACAS ≥50% in AICVD.
METHODS:
In this cross-sectional study, atherosclerosis of the coronary and brain blood-supplying arteries was simultaneously evaluated using one-step computed tomography angiography (CTA) in AICVD patients without coronary artery disease history. The patients were divided into ACAS ≥50% and non-ACAS ≥50% groups according to whether CTA showed stenosis ≥50% in at least one coronary arterial segment. The AAP characteristics of CTA were depicted from aspects of thickness, extent, and complexity.
RESULTS:
Among 118 analyzed patients with AICVD, 29/118 (24.6%) patients had ACAS ≥50%, while AAPs were observed in 86/118 (72.9%) patients. Increased AAP thickness per millimeter (adjusted odds ratio [OR]: 1.56, 95% confidence interval [CI]: 1.18-2.05), severe-extent AAP (adjusted OR: 13.66, 95% CI: 2.33-80.15), and presence of complex AAP (adjusted OR: 7.27, 95% CI: 2.30-23.03) were associated with ACAS ≥50% among patients with AICVD, independently of clinical demographics and cervicocephalic atherosclerotic stenosis. The combination of AAP thickness, extent, and complexity predicted ACAS ≥50% with an area under the receiver-operating characteristic curve of 0.78 (95% CI: 0.70-0.85, P < 0.001). All three AAP characteristics provided additional predictive power beyond cervical and intracranial atherosclerotic stenosis for ACAS ≥50% in AICVD (all P < 0.05).
CONCLUSIONS
Thicker, severe-extent, and complex AAP were significant markers of the concomitant ACAS ≥50% in AICVD, possibly superior to the indicative value of cervical and intracranial atherosclerotic stenosis. As an integral part of atherosclerosis of brain blood-supplying arteries, AAP should not be overlooked in predicting ACAS ≥50% for patients with AICVD.
Aged
;
Aorta, Thoracic
;
pathology
;
Cerebrovascular Disorders
;
diagnosis
;
Coronary Stenosis
;
diagnosis
;
Cross-Sectional Studies
;
Female
;
Humans
;
Male
;
Middle Aged
;
Odds Ratio
;
Plaque, Atherosclerotic
;
diagnosis
;
Risk Factors
7.Serial Morphological Changes of Side-Branch Ostium after Paclitaxel-Coated Balloon Treatment of De Novo Coronary Lesions of Main Vessels.
Ae Young HER ; Soe Hee ANN ; Gillian Balbir SINGH ; Yong Hoon KIM ; Takayuki OKAMURA ; Scot GARG ; Bon Kwon KOO ; Eun Seok SHIN
Yonsei Medical Journal 2016;57(3):606-613
PURPOSE: The effects on the side-branch (SB) ostium, following paclitaxel-coated balloon (PCB) treatment of de novo coronary lesions of main vessels have not been previously investigated. This study was aimed at evaluating the serial morphological changes of the SB ostium after PCB treatment of de novo coronary lesions of main vessels using optical coherence tomography (OCT). MATERIALS AND METHODS: This prospective, single-center observational study enrolled patients with de novo lesions, which were traversed by at least one SB (≥1.5 mm) and were treated with PCB. The SB ostium was evaluated with serial angiographic and OCT assessments pre- and post-procedure, and at 9-months follow-up. RESULTS: Sixteen main vessel lesions were successfully treated with PCB, and 26 SBs were included for analysis. Mean SB ostial lumen area increased at 9-months follow-up (0.92±0.68 mm2 pre-procedure, 1.03±0.77 mm2 post-procedure and 1.42±1.18 mm2 at 9-months). The SB ostial lumen area gain was 0.02±0.24 mm2 between pre- and post-procedure, 0.37±0.64 mm2 between post-procedure and 9-months, and 0.60±0.93 mm2 between pre-procedure and 9-months. The ostial lumen area increased by 3.9% [interquartile range (IQR) of -33.3 to 10.4%] between pre- and post-procedure, 52.1% (IQR of -0.7 to 77.3%) between post-procedure and 9-months and 76.1% (IQR of 18.2 to 86.6%) between pre-procedure and 9-months. CONCLUSION: PCB treatment of de novo coronary lesions of main vessels resulted in an increase in the SB ostial lumen area at 9-months.
Aged
;
Angioplasty, Balloon, Coronary/*methods
;
Coronary Angiography
;
Coronary Stenosis/diagnosis/*therapy
;
Coronary Vessels/*pathology
;
*Drug-Eluting Stents/adverse effects
;
Female
;
Humans
;
Male
;
Middle Aged
;
Paclitaxel/*administration & dosage
;
Prospective Studies
;
Tomography, Optical Coherence/*methods
;
Treatment Outcome
;
Tubulin Modulators/administration & dosage
8.Prediction of Coronary Atherosclerotic Ostial Lesion with a Damping of the Pressure Tracing during Diagnostic Coronary Angiography.
Ae Young HER ; Soe Hee ANN ; Gillian Balbir SINGH ; Yong Hoon KIM ; Bon Kwon KOO ; Eun Seok SHIN
Yonsei Medical Journal 2016;57(1):58-63
PURPOSE: When performing coronary angiography (CAG), diagnostic catheter intubation to the ostium can cause damping of the pressure tracing. The aim of this study was to determine the predictors of atherosclerotic ostial stenosis in patients showing pressure damping during CAG. MATERIALS AND METHODS: In total, 2926 patients who underwent diagnostic CAG were screened in this study. Pressure damping was defined as an abrupt decline of the coronary blood pressure with a blunted pulse pressure after engagement of the diagnostic catheter. According to CAG and intravascular ultrasound (IVUS), we divided damped ostia into two groups: atherosclerotic ostial lesion group (true lesion group) and non-atherosclerotic ostium group (false lesion group). Clinical and angiographic characteristics were compared between the two groups. RESULTS: The overall incidence of pressure damping was 2.3% (68 patients and 76 ostia). Among the pressure damped ostia, 40.8% (31 of 76 ostia) were true atherosclerotic ostial lesions (true lesion group). The true lesion group had more frequent left main ostial damping and more percutaneous coronary interventions (PCIs) performed on non-ostial lesions, compared to the false lesion group. On multivariate logistic regression analysis, left main ostial damping [hazard ratio (HR) 4.11, 95% confidence interval (CI) 1.24-13.67, p=0.021] and PCI on non-ostial lesion (HR 5.34, 95% CI 1.34-21.27, p=0.018) emerged as independent predictors for true atherosclerotic ostial lesions in patients with pressure damping. CONCLUSION: Left main ostial damping and the presence of a non-ostial atherosclerotic lesion may suggest a significant true atherosclerotic lesion in the coronary ostium.
Aged
;
*Coronary Angiography
;
Coronary Artery Disease/etiology/*radiography
;
Coronary Occlusion/diagnosis/*therapy
;
Coronary Stenosis/etiology/*radiography
;
Coronary Vessel Anomalies/radiography
;
Coronary Vessels/*pathology
;
Female
;
Humans
;
Incidence
;
Male
;
Middle Aged
;
Percutaneous Coronary Intervention/adverse effects/methods
;
Predictive Value of Tests
;
Proportional Hazards Models
;
Radiography, Interventional
9.Prognostic Value of Gai's Plaque Score and Agatston Coronary Artery Calcium Score for Functionally Significant Coronary Artery Stenosis.
Chuang ZHANG ; Shuang YANG ; Lu-Yue GAI ; Zhi-Qi HAN ; Qian XIN ; Xiao-Bo YANG ; Jun-Jie YANG ; Qin-Hua JIN
Chinese Medical Journal 2016;129(23):2792-2796
BACKGROUNDThe prognostic values of the coronary computed tomography angiography (CCTA) score for predicting future cardiovascular events have been previously demonstrated in numerous studies. However, few studies have used the rich information available from CCTA to detect functionally significant coronary lesions. We sought to compare the prognostic values of Gai's plaque score and the coronary artery calcium score (CACS) of CCTA for predicting functionally significant coronary lesions, using fractional flow reserve (FFR) as the gold standard.
METHODSWe retrospectively analyzed 107 visually assessed significant coronary lesions in 88 patients (mean age, 59.6 ± 10.2 years; 76.14% of males) who underwent CCTA, invasive coronary angiography, and invasive FFR measurement. An FFR <0.80 indicated hemodynamically significant coronary stenosis. Lesions were divided into two groups using an FFR cutoff value of 0.80. We compared Gai's plaque scores and CACS between the two groups and evaluated the correlations of these scores with FFR. The statistical methods included unpaired t-test, Mann-Whitney U-test, and Spearman's correlation coefficients.
RESULTSCoronary lesions with FFR <0.80 had higher Gai's scores than those with FFR ≥0.80. Gai's score had the strongest correlation with FFR (r = -0.48, P < 0.01) and had a greater area under the curve = 0.72 (95% confidence interval: 0.61-0.82; P < 0.01) than the CACS of whole arteries and a single artery.
CONCLUSIONSBoth CACS in a single artery and Gai's plaque score demonstrated a good capacity to assess functionally significant coronary artery stenosis when compared to the gold standard FFR. However, Gai's plaque score was more predictive of FFR <0.80. Gai's score can be easily calculated in daily clinical practice and could be used when considering revascularization.
Aged ; Computed Tomography Angiography ; Coronary Angiography ; Coronary Stenosis ; pathology ; Coronary Vessels ; pathology ; Female ; Fractional Flow Reserve, Myocardial ; physiology ; Humans ; Male ; Middle Aged ; Prognosis ; Retrospective Studies ; Vascular Calcification ; pathology
10.Comparison of Paclitaxel-Coated Balloon Treatment and Plain Old Balloon Angioplasty for De Novo Coronary Lesions.
Ae Young HER ; Soe Hee ANN ; Gillian Balbir SINGH ; Yong Hoon KIM ; Sang Yong YOO ; Scot GARG ; Bon Kwon KOO ; Eun Seok SHIN
Yonsei Medical Journal 2016;57(2):337-341
PURPOSE: This study compared the angiographic outcomes of paclitaxel-coated balloon (PCB) versus plain old balloon angioplasty (POBA) treatment for de novo coronary artery lesions. At present, there is no available data comparing the efficacy of PCB versus POBA for the treatment of de novo coronary lesions. MATERIALS AND METHODS: This multicenter retrospective observational study enrolled patients with de novo coronary lesions with a reference vessel diameter between 2.5 mm and 3.0 mm and lesion length < or =24 mm who were successfully treated with PCB or POBA. Angiographic measurements and quantitative coronary analysis were performed before and after the procedure, and at 9 months follow-up. RESULTS: A total of 72 patients (49 receiving PCB and 23 receiving POBA) were enrolled in this study. Late luminal loss was -0.12+/-0.30 mm in the PCB group and 0.25+/-0.50 mm in the POBA group (p<0.001). There was a higher percentage of binary restenosis (diameter stenosis > or =50%) in POBA, compared to PCB (30.4%, n=7 vs. 4.1%, n=2, p<0.001). Target vessel revascularization was higher in the POBA group (13.0%, n=3 vs. 0%, p=0.033). CONCLUSION: PCB treatment of de novo coronary lesions showed better 9-month angiographic outcomes than POBA treatment alone.
Aged
;
Angioplasty, Balloon, Coronary/*instrumentation/methods
;
Coronary Angiography
;
Coronary Artery Disease/therapy
;
Coronary Stenosis/*therapy
;
Coronary Vessels/pathology
;
Female
;
Follow-Up Studies
;
Humans
;
Male
;
Middle Aged
;
Paclitaxel/*administration & dosage/therapeutic use
;
Retrospective Studies

Result Analysis
Print
Save