1.Spontaneous coronary artery dissection by intravascular ultrasound in a patient with myocardial infarction.
Ji Hun JANG ; Dae Hyeok KIM ; Dong Hyuk YANG ; Seong Il WOO ; Jun KWAN ; Keum Soo PARK ; Sung Hee SHIN
The Korean Journal of Internal Medicine 2014;29(1):106-110
Spontaneous coronary artery dissection is a rare cause of acute coronary syndrome and sudden cardiac death. The incidence, causes, pathogenesis, and treatment have not been defined clearly, but spontaneous coronary artery dissection should be considered in young patients without major cardiovascular risk factors or in patients in the peripartum period who present with acute coronary syndrome. The treatment is often challenging. Medical treatment is usually considered, and percutaneous coronary intervention or coronary artery bypass surgery may be possible in some patients. We herein report two cases of middle-aged males with myocardial infarction who were treated with percutaneous coronary angioplasty.
Adult
;
Coronary Artery Disease/*complications/surgery/ultrasonography
;
Humans
;
Male
;
Middle Aged
;
Myocardial Infarction/*etiology/surgery/ultrasonography
;
*Percutaneous Coronary Intervention
;
Rupture, Spontaneous/surgery/ultrasonography
;
Ultrasonography, Interventional
2.Comparison between Measured and Calculated Length of Side Branch Ostium in Coronary Bifurcation Lesions with Intravascular Ultrasound.
Hyeon Min RYU ; Byeong Keuk KIM ; Jung Sun KIM ; Young Guk KO ; Donghoon CHOI ; Yangsoo JANG ; Myeong Ki HONG
Yonsei Medical Journal 2012;53(4):680-684
PURPOSE: Accurate evaluation of side branch (SB) ostium could be critical to the treatment of bifurcation lesions. We compared measured and calculated values of side branch ostial length (SBOL) in coronary bifurcation lesions with intravascular ultrasound (IVUS). MATERIALS AND METHODS: Pre-intervention and post-intervention IVUS was performed in 113 patients who underwent stent implantation of bifurcation lesions. For the IVUS longitudinal reconstruction of the bifurcation lesions, SBOL, SB diameter, and the angle between the distal portion of the main vessel (MV) and SB were directly measured. In addition, SBOL was calculated as: SB diameter/sin (angle between distal MV and SB). The relationship between measured and calculated SBOL was then evaluated. RESULTS: The angled between the distal MV and SB were 57.3+/-12.4degrees at pre-intervention and 59.4+/-12.6degrees at post-intervention. The mean measured and calculated SBOL values were 2.91+/-0.86 mm and 3.06+/-0.77 mm at pre-intervention and 2.79+/-0.82 mm and 2.92+/-0.69 mm at post-intervention, respectively. Differences between measured and calculated SBOL were 0.15+/-0.44 mm at pre-intervention and 0.13+/-0.41 mm at post-intervention. We found that calculated SBOL was correlated with measured SBOL (pre-intervention r=0.863, p<0.001; post-intervention r=0.868, p<0.001). CONCLUSION: There was a good correlation between measured and calculated SBOLs of the bifurcation lesions in IVUS longitudinal reconstruction. SBOL in the bifurcation lesions can therefore be estimated using the SB diameter and the angle between distal MV and SB.
Aged
;
Angioplasty, Balloon, Coronary
;
Coronary Angiography
;
Coronary Artery Disease/surgery/*ultrasonography
;
Coronary Vessels/*ultrasonography
;
Female
;
Humans
;
Male
;
Middle Aged
;
Ultrasonography, Interventional
3.Long-term outcomes of intravascular ultrasound-guided drug-eluting stent implantation in patients with chronic kidney disease: ULTIMATE CKD subgroup analysis.
Xiao Fei GAO ; Shu LU ; Leng HAN ; Xue Song QIAN ; Zhen GE ; Xiang Quan KONG ; Jing KAN ; Jun Jie ZHANG ; Shao Liang CHEN
Chinese Journal of Cardiology 2021;49(2):136-142
Objective: To explore the long-term effect of intravascular ultrasound (IVUS) guidance on patients with chronic kidney disease (CKD) undergoing drug-eluting stent (DES) implantation. Methods: Data used in this study derived from ULTIMATE trial, which was a prospective, multicenter, randomized study. From August 2014 to May 2017, 1 448 patients with coronary heart disease undergoing DES implantation were selected from 8 domestic centers and randomly divided into two groups in the ratio of 1∶1 (IVUS or coronary angiography guided stent implantation). A total of 1 443 patients with the baseline serum creatine available were enrolled. The patients were divided into CKD group and non CKD group. CKD was defined as the estimated glomerular filtration rate (eGFR) derived from Cockcroft Gault (CG) formula< 60 ml·min-1·1.73 m-2 for at least 3 months. Primary endpoint of this study was target vessel failure (TVF) at 3 years, including cardiac death, target vessel myocardial infarction, and clinically-driven target vessel revascularization. Kaplan Meier method was used for survival analysis, and log rank test was used to compare the occurrence of end-point events in each group. Cox proportional hazards model was used to calculate HR and 95%CI, and interaction was tested. Multivariate Cox regression was used to analyze the independent influencing factors of TVF. Results: A total of 1 443 patients with coronary heart disease were enrolled in this study, including 349 (24.2%) patients in CKD group and 1 094 patients in non CKD group. In CKD group, IVUS was used to guide stent implantation in 180 cases and angiography was used in 169 cases; in non CKD group, IVUS was used to guide stent implantation in 543 cases and angiography was used in 551 cases. Three-year clinical follow-up was available in 1 418 patients (98.3%). The incidence of TVF in CKD group was 12.0% (42/349), which was higher than that in non CKD group (7.4% (81/1 094) (P = 0.01). The difference was mainly due to the higher cardiac mortality in CKD group (4.6% (16/349) vs. 1.5% (16/1094), P<0.001). In CKD group, the incidence of TVF in patients who underwent IVUS guided stent implantation was lower than that in angiography guided stent implantation (8.3% (15/180) vs. 16.0% (27/169), P = 0.03). There was no significant difference in the incidence of TVF between IVUS guided stent implantation and angiography guided stent implantation in non CKD group (5.9% (32/543) vs. 8.9% (49/551), P = 0.06), and there was no interaction (P = 0.47). Multivariate Cox regression analysis showed that IVUS guidance (HR = 0.56, 95%CI 0.39-0.81, P = 0.002), CKD (HR = 1.83, 95%CI 1.17-2.87, P = 0.010) and stent length (every 10 mm increase) (HR = 1.11, 95%CI 1.04-1.19, P = 0.002) were independent risk factors for TVF within 3 years after DES implantation. Conclusions: CKD patients undergoing DES implantation are associated with a higher risk of 3-year TVF. More importantly, the risk of TVF could be significantly decreased through IVUS guidance in comparison with angiography guidance in patients with CKD.
Coronary Angiography
;
Coronary Artery Disease/surgery*
;
Drug-Eluting Stents
;
Humans
;
Percutaneous Coronary Intervention
;
Prospective Studies
;
Renal Insufficiency, Chronic
;
Treatment Outcome
;
Ultrasonography, Interventional
4.Effect of lipoprotein
Jiajia LIU ; Yu CAO ; Zhe SHENG
Journal of Central South University(Medical Sciences) 2021;46(3):249-256
OBJECTIVES:
To analyze the effect of hyperlipoproteinemia (α) on immediate expansion after coronary stent implantation guided by intravascular ultrasound (IVUS).
METHODS:
A total of 160 patients (175 lesions) with coronary heart disease diagnosed by coronary artery angiography, who were performed percutaneous intervention guided by IVUS in the Department of Cardiology, Third Xiangya Hospital, Central South University, were enrolled retrospectively.According to the concentration of lipoproteina, the patients were divided into 2 groups: a hyperlipoproteinemia (α) group and a control group. Cardiac ejection fraction was measured with echocardiography. Logistic regression was used to analyze the influential factors for hyperlipoproteinemia (α). The target vessel was examined by IVUS to analyze the immediate expansion effect of hyperlipoproteinemia (α) after stent implantation.
RESULTS:
The mean stent expansion index, lesion length, stent number, stent symmetry index and posterior balloon diameter were (94.73±18.9)%, (52.92±29.1) mm, (2.11±0.85), (83.62±13.07)%, and (9.46±2.00) mm in the hyperlipoproteinemia (α) group, respectively. Compared with the control group, there were significantly difference (all
CONCLUSIONS
Hyperlipoproteinemia (α) appears to be a predictor of stent underexpansion, and the decreased creatinine clearance rate is an independent risk factor for hyperlipoproteinemia (α).
Coronary Angiography
;
Coronary Artery Disease/surgery*
;
Humans
;
Lipoproteins
;
Percutaneous Coronary Intervention/adverse effects*
;
Retrospective Studies
;
Risk Factors
;
Stents/adverse effects*
;
Treatment Outcome
;
Ultrasonography, Interventional
5.Intravascular ultrasound evaluating coronary stents for patients with coronary artery disease: compared old with new multilink stents.
Weixin ZHOU ; Rainer HOFFMANN ; Andreas FRANKE ; Huanyi YANG ; Harald KUHL ; Peter HANRATH
Chinese Medical Sciences Journal 2002;17(2):95-100
OBJECTIVEIt was suggested that coronary stent design and coating may affect stent performance and hence induce varying degrees of thrombogenesis and neointimal hyperplasia. The purpose of this study is to compare the 6-month follow-up results between old and new Multilink stents with the method of intravascular ultrasound (IVUS) imaging.
METHODSWe have performed old (n = 40) and new (n = 35) Multilink stent implantations on 75 patients with coronary artery disease. Coronary angiography was performed before, immediately after, and 6 months after the in-stent procedure respectively. Six-month follow-up IVUS imaging was performed and analyzed off-line.
RESULTSMinimal lumen cross sectional area (CSA) of new Multilink stents was significantly larger than that of old Multilink stents (P = 0.0053). Mean stent lumen area of new Multilink stents was significantly larger than that of old Multilink stents (P = 0.040). Similarly, minimal lumen diameter (MLD) of new Multilink stents was larger than that of old Multilink stents (P = 0.011). Old Multilink stents had a higher percentage of plaque area than new Multilink stents.
CONCLUSIONThe new Multilink stent is obviously superior to old Multilink stents, in particular, in the stent MLD and lumen CSA--major determinants of the restenosis.
Adult ; Aged ; Coronary Angiography ; Coronary Artery Disease ; diagnostic imaging ; surgery ; Coronary Restenosis ; prevention & control ; Coronary Vessels ; diagnostic imaging ; pathology ; Evaluation Studies as Topic ; Female ; Humans ; Male ; Middle Aged ; Stents ; Ultrasonography, Interventional
6.Prevalence of Asymptomatic Critical Carotid Artery Stenosis in Korean Patients with Chronic Atherosclerotic Lower Extremity Ischemia: Is a Screening Carotid Duplex Ultrasonography Worthwhile?.
Woo Sung YUN ; Young Nam RHO ; Ui Jun PARK ; Kyung Bok LEE ; Dong Ik KIM ; Young Wook KIM
Journal of Korean Medical Science 2010;25(8):1167-1170
This study aimed to investigate prevalence of asymptomatic carotid artery stenosis (ACAS) in Korean patients with peripheral arterial disease (PAD) and identify predictive factors of ACAS in patients with PAD. Between 1994 and 2008, 546 patients who underwent bypass surgery due to PAD were identified in a single tertiary teaching hospital. Of those, 409 patients underwent preoperative screening carotid duplex ultrasonography (CDUS). Patients who had an episode of cerebrovascular event or previous carotid artery intervention were excluded and then a retrospective analysis was made of 340 patients. The degree of internal carotid artery (ICA) stenosis was determined by the criteria of Society of Radiologists in Ultrasound Consensus Conference. To determine the risk factors of ACAS, demographic, coexisting medical condition and lesion characteristics were tested with binary logistic regression model. The prevalence of > or =70% ICA stenosis was 14%. ICA occlusion was detected in 7.1%. Multivariate analysis revealed age >65 yr (OR: 2.610, 95% CI: 1.197-5.691) and coronary artery disease (CAD, OR: 2.333, 95% CI: 1.169-4.657) are predictive factors of > or =70% stenosis. A PAD patient who needs revascularization, particularly, >65 yr or has a concomitant CAD, can be a good candidate of screening CDUS.
Adult
;
Age Factors
;
Aged
;
Aged, 80 and over
;
Atherosclerosis/complications
;
Carotid Stenosis/complications/epidemiology/*ultrasonography
;
Chronic Disease
;
Coronary Artery Disease/diagnosis
;
Demography
;
Female
;
Humans
;
Ischemia/complications
;
Lower Extremity
;
Male
;
Middle Aged
;
Peripheral Arterial Disease/*complications/surgery
;
Predictive Value of Tests
;
Prevalence
;
Republic of Korea/epidemiology
;
Risk Factors
;
*Ultrasonography, Doppler, Duplex