1.Evaluation of Anterior Segment Parameter Changes Using the Sirius after Uneventful Phacoemulsification.
Ali ŞIMŞEK ; Burak BILGIN ; Musa ÇAPKIN ; Semsettin BILAK ; Mete GÜLER ; Ali Hakim REYHAN
Korean Journal of Ophthalmology 2016;30(4):251-257
PURPOSE: To investigate changes in anterior chamber depth (ACD), corneal volume (CV), anterior chamber angle (ACA), anterior chamber volume (ACV), central corneal thickness (CCT), horizontal visible iris diameter (HVID), pupil diameter (PD), and intraocular pressure (IOP) after uneventful phacoemulsification cataract surgery with intraocular lens implantation. METHODS: A total of 132 eyes of 132 patients (87 men and 45 women) that underwent uneventful phacoemulsification cataract surgery and intraocular lens implantation were prospectively studied. The mean age of the patients was 63.68 ± 12.51 years. All patients were evaluated preoperatively and at 1 month postoperatively with the Sirius 3D Rotating Scheimpflug camera topography system. The ACD, CV, ACA, ACV, CCT, HVID, and PD measurements were recorded. IOP was measured using the Goldmann applanation tonometer, which was corrected for CCT of the Sirius device using Ehlers' formula. RESULTS: The preoperative mean ACD, ACV, ACA, CCT, CV, PD, HVID, and IOP were 2.79 ± 0.45 mm, 124.73 ± 25.72 mm³, 42.09 ± 7.49⁰, 523.87 ± 41.97 microns, 55.37 ± 4.89 mm³, 3.98 ± 1.23 mm, 11.72 ± 0.67 mm, and 14.74 ± 2.59 mmHg, respectively. Three months postoperatively, the mean ACD, ACV, ACA, CCT, CV, PD, HVID, and IOP were 3.45 ± 0.6 mm, 162.52 ± 23.79 mm³, 51.46 ± 5.63⁰, 526.21 ± 44.45 microns, 56.23 ± 5.12 mm³, 2.87 ± 0.45 mm, 11.91 ± 0.75 mm, and 12.02 ± 1.83 mmHg, respectively. There was a statistically significant increase in mean postoperative ACD, ACV, ACA, CV, and HVID compared with the corresponding preoperative values (p < 0.05). CCT remained stable after surgery. Postoperative PD and IOP were significantly decreased compared to corresponding preoperative values (p < 0.05). CONCLUSIONS: Preoperative measurements by the Sirius 3D Rotating Scheimpflug camera topography system might help surgeons to predict postoperative changes resulting from phacoemulsification and intraocular lens implantation. This is a noncontact, noninvasive, and comfortable system for patients that is highly reliable and repeatable for anterior segment measurements.
Adolescent
;
Adult
;
Aged
;
Aged, 80 and over
;
Anterior Eye Segment/*diagnostic imaging/surgery
;
Cornea/*pathology/surgery
;
Corneal Topography/*methods
;
Female
;
Humans
;
Lens Implantation, Intraocular/*methods
;
Male
;
Middle Aged
;
Phacoemulsification/*methods
;
Postoperative Period
;
Prospective Studies
;
Treatment Outcome
;
Visual Acuity
;
Young Adult
2.Comparison of Long-term Clinical Outcomes between Descemet's Stripping Automated Endothelial Keratoplasty and Penetrating Keratoplasty in Patients with Bullous Keratopathy.
Sung Eun KIM ; Sung A LIM ; Yong Soo BYUN ; Choun Ki JOO
Korean Journal of Ophthalmology 2016;30(6):443-450
PURPOSE: To compare 2-year clinical outcomes of Descemet's stripping automated endothelial keratoplasty (DSAEK) and penetrating keratoplasty (PK) in patients with bullous keratopathy. METHODS: A retrospective chart review was performed to obtain 2 years of follow-up data of DSAEK or PK at a single center from March 2009 to September 2012. The study comprised 15 eyes of DSAEK and 11 eyes of PK. Outcome measures included best-corrected visual acuity (BCVA), spherical and keratometric changes, central corneal thickness, endothelial cell density, intraocular pressure, and postoperative complications. Graft survival rate was assessed by Kaplan-Meier survival analysis. RESULTS: There were no differences in patient baseline characteristics between the two groups. At postoperative 2 years, better BCVA of 0.69 ± 0.51 logarithm of the minimum angle of resolution (logMAR) was found after DSAEK compared to 0.88 ± 0.48 logMAR after PK. Refractive cylinder in DSAEK and PK was −2.60 ± 1.53 and −6.00 ± 1.05 diopters (D), respectively, and keratometric cylinder was 3.27 ± 3.70 and 6.34 ± 3.51 D, respectively, at postoperative 2 years. The difference of mean spherical equivalents between postoperative 1 month and 2 years was 0.84 D after DSAEK and 2.05 D after PK. A hyperopic shift of 1.17 D was present after 2 years of DSAEK. The mean endothelial cell density at postoperative 2 years was 1,548 ± 456 cells/mm² for DSAEK and 1,052 ± 567 cells/mm² for PK, with a cell loss of 19.96% vs. 52.38%, respectively when compared to postoperative 1 month. No significant difference in central corneal thickness was found between DSAEK and PK (592 ± 75 vs. 563 ± 90 µm, respectively). Finally, the 2-year survival rate did not differ significantly between DSAEK and PK (93.3% vs. 81.8%, respectively, p = 0.344). CONCLUSIONS: Compared to PK, DSAEK provided more stable refractive errors with better visual outcome, lower endothelial cell loss, and a lower rate of graft rejection at postoperative 2 years in patients with bullous keratopathy.
Cornea/diagnostic imaging/*surgery
;
Corneal Diseases/diagnosis/*surgery
;
Descemet Stripping Endothelial Keratoplasty/*methods
;
Female
;
Follow-Up Studies
;
Graft Survival
;
Humans
;
Keratoplasty, Penetrating/*methods
;
Male
;
Middle Aged
;
*Refraction, Ocular
;
Retrospective Studies
;
Time Factors
;
Treatment Outcome
;
Visual Acuity