1.A retrospective analysis of tuberculosis screening by interferon-gamma release assay at National Skin Centre, Singapore
Hazel H Oon ; Lim KS ; Chong WS ; Colin CT Theng ; Tan HH ; Benson Yeo
Malaysian Journal of Dermatology 2011;27(-):10-10
Objective
The T-Spot.TB is an interferon-gamma release assay (IGRA) which is increasingly used in dermatology as a screen for latent
TB before initiation of biologics and for confirming diagnosis of tuberculids. This study aims to explore its concordance
with tuberculin skin tests (TST) and eventual diagnosis of latent TB.
Study design
This is a retrospective review of all patients in NSC who had a TB T-spot test done between 2008 and 2010. We looked
at the dermatological diagnosis, results of T-Spot.TB and TST, chest radiograph findings, tuberculosis status and treatment
of TB.
Result
51 TB T spot tests were ordered in National Skin Centre between 1 January 2008 and 9 June 2010. 31 tests were for patients
with psoriasis with the intention of initiating biologics; 5 were for patients with suspected tuberculids and tuberculosis
verrucosa cutis; 3 were done as part of work-up for possible erythema nodosum; 3 tests were part of screening for latent
TB in hospital staff and 9 tests were performed for other reasons.
There were a total of 13 patients eventually diagnosed with latent or active TB infection. All of whom had a positive
T-Spot.TB result except for 1 patient with an indeterminate result. On the other hand, out of these 13 patients, only 5
showed a positive TST, 2 had negative TST and 4 patients did not have a TST done.
There were a total of 14 positive T-Spot.TB results for which 12 eventually received antituberculous therapy. All patients
with erythema induratum had a positive test result. Six patients’ T-Spot.TB tests were borderline, indeterminate or could
not be interpreted due to insufficient lymphocyte yield.
Conclusion
Our study shows the utility of T-Spot. TB test in various conditions seen in dermatology clinics in a local setting. We suggest
that the T-spot test can supplant the tuberculin skin test in screening latent TB for psoriasis patients for whom biologics are
intended and in erythema induratum. The high incidence of borderline and indeterminate results should not be ignored.
This should be taken into account when interpreting the IGRA especially if patients are on immunosuppressive therapy.
3.A tale of two tachycardias.
Colin YEO ; Jeremy CHOW ; Gerard LEONG ; Kah Leng HO
Singapore medical journal 2015;56(1):e10-3
A patient with non-ischaemic cardiomyopathy, and pre-existing atypical atrial flutter and left bundle branch block, developed broad complex tachycardia. In this unique and uncommon case of double tachycardia, we discuss the diagnostic approach of ventricular tachycardia in patients with broad complex tachycardia, and the use of different contemporary algorithms to help diagnose ventricular tachycardia and differentiate it from supraventricular tachycardia with aberrant conduction.
Algorithms
;
Atrial Flutter
;
complications
;
diagnosis
;
Bundle-Branch Block
;
physiopathology
;
Cardiomyopathies
;
complications
;
diagnosis
;
Diagnosis, Differential
;
Echocardiography
;
Electrocardiography
;
Humans
;
Male
;
Middle Aged
;
Tachycardia, Supraventricular
;
diagnosis
;
physiopathology
;
Tachycardia, Ventricular
;
diagnosis
;
physiopathology
4.Ablation therapies for paroxysmal atrial fibrillation: A systematic review and patient-level network meta-analysis.
Khi Yung FONG ; Joseph J ZHAO ; Yiong Huak CHAN ; Yue WANG ; Colin YEO ; Vern Hsen TAN
Annals of the Academy of Medicine, Singapore 2023;52(1):27-40
INTRODUCTION:
Despite promising trials, catheter ablation is still regarded as an adjunct to antiarrhythmic drugs (AADs) in the treatment of paroxysmal atrial fibrillation (PAF). This study aimed to compare the effectiveness of various ablation therapies and AADs.
METHOD:
Randomised controlled trials or propensity score-matched studies comparing atrial tachyarrhythmia recurrence among any combination of ablation modalities or AAD were retrieved. Kaplan-Meier curves and risk tables for this outcome were graphically reconstructed to extract patient-level data. Frequentist network meta-analysis (NMA) using derived hazard ratios (HRs), as well as 2 restricted mean survival time (RMST) NMAs, were conducted. Treatment strategies were ranked using P-scores.
RESULTS:
Across 24 studies comparing 6 ablation therapies (5,132 patients), Frequentist NMA-derived HRs of atrial fibrillation recurrence compared to AAD were 0.35 (95% confidence interval [CI]=0.25-0.48) for cryoballoon ablation (CBA), 0.34 (95% CI=0.25-0.47) for radiofrequency ablation (RFA), 0.14 (95% CI=0.07-0.30) for combined CBA and RFA, 0.20 (95% CI=0.10-0.41) for hot-balloon ablation, 0.43 (95% CI=0.15-1.26) for laser-balloon ablation (LBA), and 0.33 (95% CI=0.18-0.62) for pulmonary vein ablation catheter. RMST-based NMAs similarly showed significant benefit of all ablation therapies over AAD. The combination of CBA + RFA showed promising long-term superiority over CBA and RFA, while LBA showed favourable short-term efficacy.
CONCLUSION
The advantage of ablation therapies over AAD in preventing atrial tachyarrhythmia recurrence suggests that ablation should be considered as the first-line treatment for PAF in patients fit for the procedure. The promising nature of several specific therapies warrants further trials to elicit their long-term efficacy and perform a cost-benefit analysis.
Humans
;
Anti-Arrhythmia Agents/therapeutic use*
;
Atrial Fibrillation/surgery*
;
Catheter Ablation/methods*
;
Heart Atria
;
Network Meta-Analysis
;
Recurrence
;
Treatment Outcome
;
Randomized Controlled Trials as Topic
6.Validation of MyDiagnostick tool to identify atrial fibrillation in a multi-ethnic Asian population.
Colin YEO ; Aye Aye MON ; Vern Hsen TAN ; Kelvin WONG
Singapore medical journal 2023;64(7):430-433
INTRODUCTION:
MyDiagnostick is an atrial fibrillation (AF) screening tool that has been validated in the Caucasian population in the primary care setting.
METHODS:
In our study, we compared MyDiagnostick with manual pulse check for AF screening in the community setting.
RESULTS:
In our cohort of 671 candidates from a multi-ethnic Asian population, AF prevalence was found to be 1.78%. Of 12 candidates, 6 (50.0%) had a previous history of AF and another 6 (50.0%) were newly diagnosed with AF. Candidates found to have AF during the screening were older (72.0 ± 11.7 years vs. 56.0 ± 13.0 years, P < 0.0001) and had a higher CHADSVASC risk score (2.9 ± 1.5 vs. 1.5 ± 1.1, P = 0.0001). MyDiagnostick had a sensitivity of 100.0% and a specificity of 96.2%. In comparison, manual pulse check had a sensitivity of 83.3% and a specificity of 98.9%.
CONCLUSION
MyDiagnostick is a simple AF screening device that can be reliably used by non-specialist professionals in the community setting. Its sensitivity and specificity are comparable and validated across various studies performed in different population cohorts.
Humans
;
Atrial Fibrillation/diagnosis*
;
Heart Rate
;
Sensitivity and Specificity
;
Risk Factors
;
Electrocardiography
;
Mass Screening
7.A single-centre experience of His bundle pacing without electrophysiological mapping system: implant success rate, safety, pacing characteristics and one-year follow up.
Swee Leng KUI ; Colin YEO ; Lisa TEO ; Ai Ling HIM ; Sherida Binte SYED HAMID ; Kelvin WONG ; Vern Hsen TAN
Singapore medical journal 2023;64(6):373-378
INTRODUCTION:
Despite the challenges related to His bundle pacing (HBP), recent data suggest an improved success rate with experience. As a non-university, non-electrophysiology specialised centre in Singapore, we report our experiences in HBP using pacing system analyser alone.
METHODS:
Data of 28 consecutive patients who underwent HBP from August 2018 to February 2019 was retrospectively obtained. The clinical and technical outcomes of these patients were compared between two timeframes of three months each. Patients were followed up for 12 months.
RESULTS:
Immediate technical success was achieved in 21 (75.0%) patients (mean age 73.3 ± 10.7 years, 47.6% female). The mean left ventricular ejection fraction was 53.9% ± 12.1%. The indications for HBP were atrioventricular block (n = 13, 61.9%), sinus node dysfunction (n = 7, 33.3%) and upgrade from implantable cardioverter-defibrillator to His-cardiac resynchronisation therapy (n = 1, 4.8%). No significant difference was observed in baseline characteristics between Timeframe 1 and Timeframe 2. Improvements pertaining to mean fluoroscopy time were achieved between the two timeframes. There was one HBP-related complication of lead displacement during Timeframe 1. All patients with successful HBP achieved non-selective His bundle (NSHB) capture, whereas only eight patients had selective His bundle (SHB) capture. NSHB and SHB capture thresholds remained stable at the 12-month follow-up.
CONCLUSION
Permanent HBP is feasible and safe, even without the use of an electrophysiology recording system. This was successfully achieved in 75% of patients, with no adverse clinical outcomes during the follow-up period.
Humans
;
Female
;
Middle Aged
;
Aged
;
Aged, 80 and over
;
Male
;
Bundle of His
;
Follow-Up Studies
;
Stroke Volume
;
Retrospective Studies
;
Treatment Outcome
;
Cardiac Pacing, Artificial/adverse effects*
;
Electrocardiography
;
Ventricular Function, Left/physiology*
8.Therapeutic temperature management (TTM): post-resuscitation care for adult cardiac arrest, with recommendations from the National TTM Workgroup.
Siew Hon Benjamin LEONG ; Enoch CHAN ; Benjamin Choon Heng HO ; Colin YEO ; Sennen LEW ; Duu Wen SEWA ; Shir Lynn LIM ; Chee Wan LEE ; Pow Li CHIA ; Tien Siang Eric LIM ; Eng Kiang LEE ; Marcus Eng Hock ONG
Singapore medical journal 2017;58(7):408-410
Therapeutic temperature management (TTM) was strongly recommended by the 2015 International Liaison Committee on Resuscitation as a component of post-resuscitation care. It has been known to be effective in improving the survival rate and neurologic functional outcome of patients after cardiac arrest. In an effort to increase local adoption of TTM as a standard of post-resuscitation care, this paper discusses and makes recommendations on the treatment for local providers.