1.Thin layer immunoassay (TIA) for circulating antibody detection in clonorchiasis.
The Korean Journal of Parasitology 1983;21(1):1-5
Thin layer immunoassay was carried out to demonstrate antibodies against Clonorchis sinensis in sera from clonorchiasis patients. Saline extract of adult worm was used as antigen. TIA technique was performed as described earlier by Elwing et al. (1976), but agarose was used instead of agar. The antibody titres of sera in 60 clonorchiasis cases were higher than that of 10 healthy and 10 amoebiasis cases, but not different comparing with that of 10 paragonimiasis cases. Antibody titres in clonorchiasis gave no differences according to the age, sex, EPG in feces, eosinophilia degree of blood, level of alkaline phosphatase and transaminase (SGOT, SGPT) in sera. It is suggested that, after evaluation, the TIA might supplement or be used as an alternative to other immunodiagnostic tests already in use for the diagnosis of clonorchiasis.
parasitology-helminth-trematoda
;
Clonorchis sinensis
;
clonorchiasis
;
immunology
2.Thin layer immunoassay (TIA) for circulating antibody detection in clonorchiasis.
The Korean Journal of Parasitology 1983;21(1):1-5
Thin layer immunoassay was carried out to demonstrate antibodies against Clonorchis sinensis in sera from clonorchiasis patients. Saline extract of adult worm was used as antigen. TIA technique was performed as described earlier by Elwing et al. (1976), but agarose was used instead of agar. The antibody titres of sera in 60 clonorchiasis cases were higher than that of 10 healthy and 10 amoebiasis cases, but not different comparing with that of 10 paragonimiasis cases. Antibody titres in clonorchiasis gave no differences according to the age, sex, EPG in feces, eosinophilia degree of blood, level of alkaline phosphatase and transaminase (SGOT, SGPT) in sera. It is suggested that, after evaluation, the TIA might supplement or be used as an alternative to other immunodiagnostic tests already in use for the diagnosis of clonorchiasis.
parasitology-helminth-trematoda
;
Clonorchis sinensis
;
clonorchiasis
;
immunology
3.Studies on the immunodiagnosis of rabbit clonorchiasis II. Immunoaffinity purification of whole worm antigen and characterization of egg, metacercaria and adult antigens of Clonorchis sinensis.
Ok Ran LEE ; Pyung Rim CHUNG ; Hae Seon NAM
The Korean Journal of Parasitology 1988;26(2):73-86
The sensitivity and specificity of crude and affinity-purified antigens of Clonorchis sinensis obtained from the infected rabbits were studied. Stage-specific antigenic proteins from the eggs, metacercariae and adult worms were characterized by SDS-polyacrylamide gel electrophoresis (SDS-PAGE) and enzyme-linked immunosorbent assay (ELISA) The results were as follows: The antibody-binding antigen (ABA) purified from whole worm crude antigen (WWA) by CNBr-activated Sepharose 4B affinity chromatography made 4 specific bands against rabbit anti-sera on Ouchterlony gel diffusion plate, while WWA made 7 bands. Major WWA protein bands by SDS-PAGE were found at 16,300-18,500 and 28,000-29,000 daltons, while major ABA protein bands were at 18,000-21,000 and 29,000-31,000 daltons. The reactivity of ABA with rabbit anti-sera in ELISA was remarkably less sensitive than that of WWA. Molecular weights of egg antigen (EGA), metacercarial antigen (MEA) and adult worm antigen (WWA) of C. sinensis ranged from 15,000-200,000 daltons, 15,000-100,000 daltons and 11,000-80,000 daltons, respectively. Major WWA proteins consisted mainly of polypeptide bands of low molecular weight, less than 31,000 daltons, while those of EGA and MEA consisted of higher molecular weights than 30,000 daltons. The ELISA reactivities of WWA to rabbit anti-sera were remarkably greater than those of MEA. EGA showed negative reaction throughout the experiments. WWA showed higher optical density (O.D.) than 1.0, when reacted with rabbit anti-sera obtained at 4-6 weeks after the infection. In the rabbit anti-sera later than 12 weeks after the infection, the O.D. reacting with WWA showed a plateau without variation. MEA showed relatively low O.D. values (<0.6), when reacted with anti-sera from lightly infected groups throughout the experiments, although there were some weak positive cases (O.D.>0.6) in heavily infected groups. MEA reacted with rabbit anti-sera showed negative results on Ouchterlony gel diffusion plates. Summarizing the above results, it is suggested that the whole worm antigen prepared from the adult worms of C. sinensis is most highly antigenic. However, this antigen might reveal cross reactions with other trematodes such as Paragonimus westermani, therefore, purification of antigenic proteins from the crude antigen is essential to increase the sensitivity and specificity for the immunodiagnosis of clonorchiasis.
parasitology-helminth-trematoda
;
Clonorchis sinensis
;
clonorchiasis
;
rabbit
;
immunology
;
diagnosis
;
antigen
4.Excretory-secretory antigen is better than crude antigen for the serodiagnosis of clonorchiasis by ELISA.
Min Ho CHOI ; Il Chan PARK ; Shunyu LI ; Sung Tae HONG
The Korean Journal of Parasitology 2003;41(1):35-39
Although stool examination is the standard diagnostic method of clonorchiasis, serodiagnosis by ELISA using crude antigen is now widely used because of its convenience. However, ELISA diagnosis still suffers from cross-reactions, and therefore there is a need to improve the present conventional ELISA. The present study was undertaken to evaluate the diagnostic value of ELISA using excretory-secretory antigen (ESA) instead of crude antigen (CA) of Clonorchis sinensis. The diagnostic sensitivity of ELISA using excretory-secretory antigen was 92.5%, which was higher than that of ELISA using crude Clonorchis sinensis antigen (88.2%). In addition, the specificity of excretory-secretory antigen was found 93.1% while that of crude antigen was 87.8%. In summary, Clonorchis sinensis ESA was found to be a better serodiagnostic antigen than CA for ELISA.
Animals
;
Antigens, Helminth/*analysis/immunology
;
Clonorchiasis/*diagnosis/*immunology
;
Clonorchis sinensis/immunology
;
Enzyme-Linked Immunosorbent Assay/*methods
;
Sensitivity and Specificity
5.Comparison of agar-gel diffusion tests, counterimmunoelectrophoresis and enzyme-linked immunosorbent assay in the sera of skin test positives for paragonimiasis.
The Korean Journal of Parasitology 1983;21(2):270-280
Agar-gel diffusion test (AGD), counterimmunoelectrophoresis (CIEP) and enzyme-linked immunosorbent assay(ELISA) were examined with the sera of skin test positives for paragonimiasis. The crude antigen(Paragonimus whole worm extracts: protein concentration, 7.56mg/ml) and human sera were used in AGD and CIEP. And in ELISA test, diluted antigen with 1:40,000 of crude antigen and diluted sera with 1:100, 1:200 were used in the test. The positive identical ratio between AGD and CIEP reactions is 98 percent and negative identical ratio is 100 percent. One or three precipitin bands are observed in AGD. One to seven precipitin bands are also revealed in CIEP. Especially, deeply stained bands are observed in CIEP than those of AGD. The positive identical ratios between AGD and ELISA tests are 96 percent in 1:100 diluted sera, and 94 percent in 1:200 diluted sera. But the negative identical ratios between AGD and ELISA tests are 97 percent and 99 percent respectively in 1:100 and 1:200 diluted sera. The positive identical ratios between CIEP and ELISA tests are 98 percent and 96 percent respectively in 1:100 and 1:200 diluted sera, but also 97 percent and 99 percent in 1:100 and 1:200. Control sera, such as clonorchiasis, amoebiasis and toxoplasmosis, revealed all negatives with Paragonimus antigen in AGD, CIEP and ELISA tests. By above results, ELISA was most sensitive, next CIEP and AGD. But AGD test appears to be more useful when used to crude antigen without cross reaction with other parasitic infections. CIEP test is basically equal in terms of precipitin reaction, but CIEP is able to be detected more sensitively and rapidly though less simple in handiwork than AGD. Consequently, three methods for immunological tests of paragonimiasis have good correlations with one another. Also, each of these has both merits and demerits in immunological test for paragonimiasis. But the ELISA test was proved to be the most sensitive and convenient tool for mass screening test, especially in case of using purified antigen.
parasitology-helminth-trematoda
;
Clonorchis sinensis
;
clonorchiasis
;
ELISA
;
immunology
;
diagnosis
;
paragonimiasis
;
Paragonimus westermani
;
agar-gel diffusion
;
counterimmunoelectrophoresis
6.Comparison of TIA with ELISA for circulating antibody detection in clonorchiasis.
Yong Kie LEE ; Jae Sook RYU ; Keun Tae LEE ; Kyung Il IM
The Korean Journal of Parasitology 1983;21(2):265-269
A comparison was made of a new serological method, thin layer immunoassay (TIA), and an established method, enzyme-linked immunosorbent assay (ELISA), in the detection and quantification of antibodies in clonorchiasis. Saline extract of lyophilized Clonorchis sinensis adult worm was used as antigen, and TIA by the method of Elwing et al. (1976) and ELISA by Voller et al. (1974) were performed. Using sera from known clonorchiasis cases, 100 percent of the sera tested were positive by TIA and 88.3 percent by ELISA. TIA produced false positive results in 14 out of 36 cases, which were 10 amoebiasis cases, 16 paragonimiasis cases and 10 healthy controls. ELISA, however, produced a small number of false positives, 7 out of 55 cases. There was correlation between immunoglobulin G level in sera and ELISA value (correlation coefficient, 0.69), whereas no correlation between immunoglobulin G level and TIA result. The performance of TIA and ELISA was not correlated in the results using homologous antigen.
parasitology-helminth-trematoda
;
Clonorchis sinensis
;
clonorchiasis
;
ELISA
;
immunology
;
diagnosis
;
thin-layer immunoassay
7.Immunological tests by anti-free-living amoebas serum produced in experimental animals II. Indirect fluorescent antibody titer of anti-free-living amoebas serum produced in rabbits.
The Korean Journal of Parasitology 1978;16(2):134-139
The indirect fluorescent antibody test was performed to demonstrate the antibody production in the rabbits immunized with free-living amoebas; Acanthamoeba culbertsoni and Naegleria fowleri, and antibody titer changes by immunization duration. Rabbits were immunized with Acanthamoeba culbertsoni and Naegleria fowleri which were cultured axenically in CGVS medium. For experiments, rabbits were divided into two groups; small dose group received 10(4) intravenously with live or dead free-living amoebas trophozoites as an immunizing dose three times with one week interval, and large dose group received 10(6) live or dead trophozoites respectively. The control group received physiologic saline or medium for culture of free-living amoebas intravenously. Antiserum was collected 4 times at interval of 3 days in the first 10 days, and also up to 2 months later. In the group immunized with live Acanthamoeba culbertsoni, fluorescent antibody titer was higher than in the group of dead one, and also in the large dose group than in the small dose group. Antibody titer of anti-Naegleria fowleri serum in the large dose group showed no difference by the source of amoeba antigen; live or dead. But in the small dose group, antibody titer was higher in the immunized with live Naegleria fowleri than in the group with dead one. No cross reactivity was demonstrated between the Acanthamoeba and Naegleria. And no cross reaction was observed when the free-living amoebas antigens were tested against human sera of amoebiasis, paragonimiasis and clonorchiasis.
parasitology-protozoa
;
free-living amoeba
;
Acanthamoeba culbertsoni
;
Naegleria fowleri
;
immunology
;
fluorescence
;
rabbit
;
amoebiasis
;
paragonimiasis
;
clonorchiasis
8.Evaluation of specific IgE antibody in Clonorchis sinensis infection.
Duk Young MIN ; Chin Thack SOH
The Korean Journal of Parasitology 1983;21(1):27-31
Serum IgE level and Clonorchis specific IgE in individuals with Clonorchis sinensis were determined by radioimmunosorbent(RIST) and radioallergosorbent technique(RAST) respectively. Highly significant elevations of serum IgE (P<0.001) and specific IgE antibodies (P<0.01) were observed in area from individuals with clonorchiasis. The mean values of serum IgE in individuals with clonorchiasis and healthy individuals were 2,372 IU/ml and 364 IU/ml respectively and specific IgE antibodies of both groups were 52.0 and 4.4%. A close correlation(r=0.9451) between serum IgE level and specific IgE antibodies were observed and correlation (r=0.6056) between serum IgE and EPG and between specific IgE and EPG(r=0.5693) were also observed.
parasitology-helminth-trematoda
;
Clonorchis sinensis
;
clonorchiasis
;
immunology
;
radioimmunosorbent test
;
radioallergosorbent test
;
IgA
;
IgE
;
serum
9.Detection of specific serum IgE in clonorchiasis cases and analysis of Clonorchis sinensis allergens.
Tai Soon YONG ; Dong Soo KIM ; Soo Young LEE ; Kyung Il IM ; Ki Young LEE
Yonsei Medical Journal 1993;34(3):248-257
Specific serum IgE levels of Clonorchis sinensis in infected humans were measured by avidin-biotin ELISA, and allergens from C. sinensis were identified by immunoblot and autoradiography. Then, allergens fractionated by Sephadex G-200 gel filtration were analyzed, and cross-reactive allergenic components of C. sinensis reacted with paragonimiasis sera were revealed. Fourteen out of 15 C. sinensis egg-positives were found to be serum IgE positive (absorbance > 0.27). Of 14 IgE-reacting allergen bands visualized, major allergens of 66, 61.5, 45, 37, 28.5, 23.5 and 15.5 KD were recognized by more than 50% of the sera of infected humans. The considerable individual variations of IgE immune responses to C. sinensis allergenic components were also noticed. C. sinensis extract was separated into 5 fractions by Sephadex G-200 gel filtration. Seventy-four KD allergen was recognized in the first fraction, 50, 45, 37, 29.5 and 28.5 KD in the third, and 15.5 KD in the fourth. Cross-reactive allergens with sera of paragonimiasis cases were identified as 66, 45, 28.5, 13 and 7.5 KD.
Allergens/*immunology
;
Animal
;
Antibodies, Helminth/*blood
;
Antigens, Helminth/*immunology
;
Clonorchiasis/*immunology
;
Clonorchis sinensis/*immunology
;
Cross Reactions
;
Human
;
Immunoglobulin E/*blood
;
Support, Non-U.S. Gov't
10.Changing Patterns of Serum and Bile Antibodies in Re-infected Rats with Clonorchis sinensis.
Hongman ZHANG ; Byung Suk CHUNG ; Shunyu LI ; Min Ho CHOI ; Sung Tae HONG
The Korean Journal of Parasitology 2008;46(1):17-22
Rats develop strong resistance to re-infection and super-infection by Clonorchis sinensis. The present study investigated the antibodies present in the sera and bile juice of rats that were primary infected and re-infected with C. sinensis. The serum level of specific IgG antibodies, which were elevated 2 wk of the primary infection, peaked at 4 wk and subsequently remained unchanged even during re-infection. The total IgE level in serum increased slowly from 388 ng / ml to 3,426 ng / ml beginning 2 wk after the primary infection, and remained high up to 8 wk but dropped to a normal level (259 ng / ml) after treatment. In resistant re-infected rats, the serum IgE level increased rapidly and peaked within 1 wk, whereas no increase was observed in immunosuppressed rats. The serum level of specific IgA antibodies was elevated beginning 1 wk after infection, and decreased 4 wk after treatment. The total bile IgA level unchanged during the primary infection but increased in treated and re-infected rats. The elevated levels of serum IgE and bile IgA indicate that these immunoglobulins may be correlated with the development of resistance to re-infection by C. sinensis in rats.
Animals
;
Antibodies, Helminth/analysis/*blood/*immunology/metabolism
;
Bile/*immunology
;
Clonorchiasis/blood/*immunology
;
Clonorchis sinensis/*immunology/*physiology
;
Immunoglobulin A/analysis/blood
;
Male
;
Rats
;
Rats, Sprague-Dawley
;
Time Factors