1.Reference Intervals of Hematology and Clinical Chemistry Analytes for 1-Year-Old Korean Children.
Hye Ryun LEE ; Sue SHIN ; Jong Hyun YOON ; Eun Youn ROH ; Ju Young CHANG
Annals of Laboratory Medicine 2016;36(5):481-488
BACKGROUND: Reference intervals need to be established according to age. We established reference intervals of hematology and chemistry from community-based healthy 1-yr-old children and analyzed their iron status according to the feeding methods during the first six months after birth. METHODS: A total of 887 children who received a medical check-up between 2010 and 2014 at Boramae Hospital (Seoul, Korea) were enrolled. A total of 534 children (247 boys and 287 girls) were enrolled as reference individuals after the exclusion of data obtained from children with suspected iron deficiency. Hematology and clinical chemistry analytes were measured, and the reference value of each analyte was estimated by using parametric (mean±2 SD) or nonparametric methods (2.5-97.5th percentile). Iron, total iron-binding capacity, and ferritin were measured, and transferrin saturation was calculated. RESULTS: As there were no differences in the mean values between boys and girls, we established the reference intervals for 1-yr-old children regardless of sex. The analysis of serum iron status according to feeding methods during the first six months revealed higher iron, ferritin, and transferrin saturation levels in children exclusively or mainly fed formula than in children exclusively or mainly fed breast milk. CONCLUSIONS: We established reference intervals of hematology and clinical chemistry analytes from community-based healthy children at one year of age. These reference intervals will be useful for interpreting results of medical check-ups at one year of age.
Breast Feeding
;
Clinical Chemistry Tests/*standards
;
Female
;
Hematologic Tests/*standards
;
Humans
;
Infant
;
Iron/*blood/standards
;
Male
;
Reference Values
;
Republic of Korea
2.Two Evaluation Budgets for the Measurement Uncertainty of Glucose in Clinical Chemistry.
Hui CHEN ; Ling ZHANG ; Xiaoyun BI ; Xiaoling DENG
The Korean Journal of Laboratory Medicine 2011;31(3):167-171
BACKGROUND: Measurement uncertainty characterizes the dispersion of the quantity values attributed to a measurand. Although this concept was introduced to medical laboratories some years ago, not all medical researchers are familiar with it. Therefore, the evaluation and expression of measurement uncertainty must be highlighted using a practical example. METHODS: In accordance with the procedure for evaluating and expressing uncertainty, provided by the Joint Committee for Guides in Metrology (JCGM), we used plasma glucose (Glu) as an example and defined it as the measurand. We then analyzed the main sources of uncertainty, evaluated each component of uncertainty, and calculated the combined uncertainty and expanded uncertainty with 2 budgets for single measurements and continuous monitoring, respectively. RESULTS: During the measurement of Glu, the main sources of uncertainty included imprecision, within-subject biological variance (BVw), calibrator uncertainty, and systematic bias. We evaluated the uncertainty of each component to be 1.26%, 1.91%, 5.70%, 0.42%, and -2.87% for within-run imprecision, between-day imprecision, BVw, calibrator uncertainty, and systematic bias, respectively. For a single specimen, the expanded uncertainty was 7.38% or 6.1+/-0.45 mmol/L (kappa=2); in continuous monitoring of Glu, the expanded uncertainty was 13.58% or 6.1+/-0.83 mmol/L (kappa=2). CONCLUSIONS: We have demonstrated the overall procedure for evaluating and reporting uncertainty with 2 different budgets. The uncertainty is not only related to the medical laboratory in which the measurement is undertaken, but is also associated with the calibrator uncertainty and the biological variation of the subject. Therefore, it is helpful in explaining the accuracy of test results.
Blood Chemical Analysis/methods/standards
;
Clinical Chemistry Tests/*methods/standards
;
Glucose/*analysis/standards
;
Humans
;
Models, Statistical
;
Quality Control
;
*Uncertainty
3.Two Evaluation Budgets for the Measurement Uncertainty of Glucose in Clinical Chemistry.
Hui CHEN ; Ling ZHANG ; Xiaoyun BI ; Xiaoling DENG
The Korean Journal of Laboratory Medicine 2011;31(3):167-171
BACKGROUND: Measurement uncertainty characterizes the dispersion of the quantity values attributed to a measurand. Although this concept was introduced to medical laboratories some years ago, not all medical researchers are familiar with it. Therefore, the evaluation and expression of measurement uncertainty must be highlighted using a practical example. METHODS: In accordance with the procedure for evaluating and expressing uncertainty, provided by the Joint Committee for Guides in Metrology (JCGM), we used plasma glucose (Glu) as an example and defined it as the measurand. We then analyzed the main sources of uncertainty, evaluated each component of uncertainty, and calculated the combined uncertainty and expanded uncertainty with 2 budgets for single measurements and continuous monitoring, respectively. RESULTS: During the measurement of Glu, the main sources of uncertainty included imprecision, within-subject biological variance (BVw), calibrator uncertainty, and systematic bias. We evaluated the uncertainty of each component to be 1.26%, 1.91%, 5.70%, 0.42%, and -2.87% for within-run imprecision, between-day imprecision, BVw, calibrator uncertainty, and systematic bias, respectively. For a single specimen, the expanded uncertainty was 7.38% or 6.1+/-0.45 mmol/L (kappa=2); in continuous monitoring of Glu, the expanded uncertainty was 13.58% or 6.1+/-0.83 mmol/L (kappa=2). CONCLUSIONS: We have demonstrated the overall procedure for evaluating and reporting uncertainty with 2 different budgets. The uncertainty is not only related to the medical laboratory in which the measurement is undertaken, but is also associated with the calibrator uncertainty and the biological variation of the subject. Therefore, it is helpful in explaining the accuracy of test results.
Blood Chemical Analysis/methods/standards
;
Clinical Chemistry Tests/*methods/standards
;
Glucose/*analysis/standards
;
Humans
;
Models, Statistical
;
Quality Control
;
*Uncertainty
4.Application of benchmark dose on occupational epidemiology research in lead exposure.
Lin TIAN ; Tai-yi JIN ; Xiao-ting LU
Chinese Journal of Preventive Medicine 2005;39(6):406-408
OBJECTIVETo use the data of occupational epidemiology to estimate the benchmark dose (BMD) of renal dysfunction induced by lead.
METHODSBlood lead was considered as an exposure biomarker, while urinary total protein (TP), urinary beta(2)-microglobulin (beta(2)-MG) and urinary N-Acetyl-beta-D-glucosaminidase (NAG) were considered as effect biomarkers reflecting the damage of renal function. The dichotomized (binary) data was used as effect endpoints. The BMD and BMD lower limit (BMDL) of blood lead were estimated at the 10% benchmark response using BMDS version 1.3.1.
RESULTSThere was an increased prevalence of hyper-TP-uria, hyper-beta(2)-MG-uria and hyper-NAG-uria with an increasing blood lead concentration. There was obviously dose-response relationship between blood lead and TP, beta(2)-MG and NAG, respectively. The BMD and BMDL of blood lead affecting renal function were estimated to be 323.6 - 754.3 microg/L and 274.2 - 541.5 microg/L. The BMDL of blood lead was ranged from low to high as NAG, TP and beta(2)-MG. The urinary NAG activity might be served as a sensitive biomarker in detecting early renal dysfunction.
CONCLUSIONIt should be feasible to use the BMD approach to set up the reference dose (RfD) and reference concentration (RfC). BMD approach might provide a new and better way for setting up the RfD/RfC.
Acetylglucosaminidase ; urine ; China ; epidemiology ; Clinical Chemistry Tests ; methods ; standards ; Humans ; Lead ; blood ; Lead Poisoning ; blood ; epidemiology ; urine ; Occupational Exposure ; analysis ; Prevalence ; Proteinuria ; urine ; beta 2-Microglobulin ; urine
5.New Decision Criteria for Selecting Delta Check Methods Based on the Ratio of the Delta Difference to the Width of the Reference Range Can Be Generally Applicable for Each Clinical Chemistry Test Item.
Sang Hyuk PARK ; So Young KIM ; Woochang LEE ; Sail CHUN ; Won Ki MIN
Annals of Laboratory Medicine 2012;32(5):345-354
BACKGROUND: Many laboratories use 4 delta check methods: delta difference, delta percent change, rate difference, and rate percent change. However, guidelines regarding decision criteria for selecting delta check methods have not yet been provided. We present new decision criteria for selecting delta check methods for each clinical chemistry test item. METHODS: We collected 811,920 and 669,750 paired (present and previous) test results for 27 clinical chemistry test items from inpatients and outpatients, respectively. We devised new decision criteria for the selection of delta check methods based on the ratio of the delta difference to the width of the reference range (DD/RR). Delta check methods based on these criteria were compared with those based on the CV% of the absolute delta difference (ADD) as well as those reported in 2 previous studies. RESULTS: The delta check methods suggested by new decision criteria based on the DD/RR ratio corresponded well with those based on the CV% of the ADD except for only 2 items each in inpatients and outpatients. Delta check methods based on the DD/RR ratio also corresponded with those suggested in the 2 previous studies, except for 1 and 7 items in inpatients and outpatients, respectively. CONCLUSIONS: The DD/RR method appears to yield more feasible and intuitive selection criteria and can easily explain changes in the results by reflecting both the biological variation of the test item and the clinical characteristics of patients in each laboratory. We suggest this as a measure to determine delta check methods.
Alanine Transaminase/blood
;
Alkaline Phosphatase/blood
;
Aspartate Aminotransferases/blood
;
Bilirubin/blood
;
Blood Urea Nitrogen
;
Chemoembolization, Therapeutic
;
Clinical Chemistry Tests/methods/*standards
;
Creatine/blood
;
*Decision Trees
;
Humans
;
Reference Values
;
Renal Dialysis
;
Uric Acid/blood
6.New Decision Criteria for Selecting Delta Check Methods Based on the Ratio of the Delta Difference to the Width of the Reference Range Can Be Generally Applicable for Each Clinical Chemistry Test Item.
Sang Hyuk PARK ; So Young KIM ; Woochang LEE ; Sail CHUN ; Won Ki MIN
Annals of Laboratory Medicine 2012;32(5):345-354
BACKGROUND: Many laboratories use 4 delta check methods: delta difference, delta percent change, rate difference, and rate percent change. However, guidelines regarding decision criteria for selecting delta check methods have not yet been provided. We present new decision criteria for selecting delta check methods for each clinical chemistry test item. METHODS: We collected 811,920 and 669,750 paired (present and previous) test results for 27 clinical chemistry test items from inpatients and outpatients, respectively. We devised new decision criteria for the selection of delta check methods based on the ratio of the delta difference to the width of the reference range (DD/RR). Delta check methods based on these criteria were compared with those based on the CV% of the absolute delta difference (ADD) as well as those reported in 2 previous studies. RESULTS: The delta check methods suggested by new decision criteria based on the DD/RR ratio corresponded well with those based on the CV% of the ADD except for only 2 items each in inpatients and outpatients. Delta check methods based on the DD/RR ratio also corresponded with those suggested in the 2 previous studies, except for 1 and 7 items in inpatients and outpatients, respectively. CONCLUSIONS: The DD/RR method appears to yield more feasible and intuitive selection criteria and can easily explain changes in the results by reflecting both the biological variation of the test item and the clinical characteristics of patients in each laboratory. We suggest this as a measure to determine delta check methods.
Alanine Transaminase/blood
;
Alkaline Phosphatase/blood
;
Aspartate Aminotransferases/blood
;
Bilirubin/blood
;
Blood Urea Nitrogen
;
Chemoembolization, Therapeutic
;
Clinical Chemistry Tests/methods/*standards
;
Creatine/blood
;
*Decision Trees
;
Humans
;
Reference Values
;
Renal Dialysis
;
Uric Acid/blood