1.The influence of nanofillers on the properties of ethanol-solvated and non-solvated dental adhesives
Leonardo Bairrada Tavares DA CRUZ ; Marcelo Tavares OLIVEIRA ; Cintia Helena Coury SARACENI ; Adriano Fonseca LIMA
Restorative Dentistry & Endodontics 2019;44(3):e28-
OBJECTIVES: The aim of this study was to evaluate the influence of different concentrations of nanofillers on the chemical and physical properties of ethanol-solvated and non-solvated dental adhesives. MATERIALS AND METHODS: Eight experimental adhesives were prepared with different nanofiller concentrations (0, 1, 2, and 4 wt%) and 2 solvent concentrations (0% and 10% ethanol). Several properties of the experimental adhesives were evaluated, such as water sorption and solubility (n = 5, 20 seconds light activation), real-time degree of conversion (DC; n = 3, 20 and 40 seconds light activation), and stability of cohesive strength at 6 months (CS; n = 20, 20 seconds light activation) using the microtensile test. A light-emitting diode (Bluephase 20i, Ivoclar Vivadent) with an average light emittance of 1,200 mW/cm2 was used. RESULTS: The presence of solvent reduced the DC after 20 seconds of curing, but increased the final DC, water sorption, and solubility of the adhesives. Storage in water reduced the strength of the adhesives. The addition of 1 wt% and 2 wt% nanofillers increased the polymerization rate of the adhesives. CONCLUSIONS: The presence of nanofillers and ethanol improved the final DC, although the DC of the solvated adhesives at 20 seconds was lower than that of the non-solvated adhesives. The presence of ethanol reduced the strength of the adhesives and increased their water sorption and solubility. However, nanofillers did not affect the water sorption and strength of the tested adhesives.
Adhesives
;
Dental Cements
;
Ethanol
;
Longevity
;
Polymerization
;
Polymers
;
Solubility
;
Solvents
;
Water
2.Effects of radiant exposure and wavelength spectrum of light-curing units on chemical and physical properties of resin cements.
Adriano Fonseca LIMA ; Stephanie Ellen Ferreira FORMAGGIO ; Lígia França Aires ZAMBELLI ; Alan Rodrigo Muniz PALIALOL ; Giselle Maria MARCHI ; Cintia Helena Coury SARACENI ; Marcelo Tavares DE OLIVEIRA
Restorative Dentistry & Endodontics 2016;41(4):271-277
OBJECTIVES: In this study, we evaluated the influence of different radiant exposures provided by single-peak and polywave light-curing units (LCUs) on the degree of conversion (DC) and the mechanical properties of resin cements. MATERIALS AND METHODS: Six experimental groups were established for each cement (RelyX ARC, 3M ESPE; LuxaCore Dual, Ivoclar Vivadent; Variolink, DMG), according to the different radiant exposures (5, 10, and 20 J/cm²) and two LCUs (single-peak and polywave). The specimens were made (7 mm in length × 2 mm in width × 1 mm in height) using silicone molds. After 24 hours of preparation, DC measurement was performed using Fourier transform infrared spectrometry. The same specimens were used for the evaluation of mechanical properties (flexural strength, FS; elastic modulus, E) by a three-point bending test. Data were assessed for normality, after which two-way analysis of variance (ANOVA) and post hoc Tukey's test were performed. RESULTS: No properties of the Variolink cement were influenced by any of the considered experimental conditions. In the case of the RelyX ARC cement, DC was higher when polywave LCU was used; FS and E were not influenced by the conditions evaluated. The LuxaCore cement showed greater sensitivity to the different protocols. CONCLUSIONS: On the basis of these results, both the spectrum of light emitted and the radiant exposure used could affect the properties of resin cements. However, the influence was material-dependent.
Elastic Modulus
;
Fourier Analysis
;
Fungi
;
Resin Cements*
;
Silicon
;
Silicones
;
Spectrum Analysis