1.Application of evidence-based medicine in standardized residency training of dental general practitioners
Yichen JIANG ; Chao FU ; Tingting XIAO ; Binbin TAO ; Chunyan AO ; Zhaowu CHAI
Chinese Journal of Medical Education Research 2021;20(2):202-204
In order to make up for the innovation deficiency in the traditional residency training model and the shortcomings of active learning and lifelong learning, evidence-based medicine is introduced into the residency training of dental general practitioners. Theoretical knowledge training of evidence-based medicine is conducted through online course learning. PICO mode is used to conduct evidence-based analysis of clinical cases under the guidance of the instructor, so that trainees can get familiar with the process of evidence-based analysis. Students can finally design and complete the application cases of evidence-based medicine, and teachers give evaluation guidance. Through this process, students can learn and master the knowledge of evidence-based medicine step by step, thus obtaining better teaching results.
2.Establishment and evaluation of HPLC-MS/MS method in determining serum H2S
Xiangyu MENG ; Ao ZHANG ; Chunyan LI
China Medical Equipment 2024;21(2):42-47
Objective:To establish a determination method of high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)for serum hydrogen sulfide(H2S),so as to determine serum H2S.Methods:This study collected serum samples of 30 patients who admitted to Beijing Jishuitan Hospital affiliated to Capital Medical University from April 2023 to May 2023,and they were divided into osteoporosis group and control group according to whether existed osteoporosis,with 15 cases in each group.HPLC-MS/MS and enzyme-linked immunosorbent assay were used respectively to determine serum H2S.And then,the precision,accuracy and correlation between the two methods were evaluated.Results:HPLC-MS/MS can fast detect the content of serum H2S through detecting methylene blue in the serum,which analysis time was only 1.5 minutes,and its specificity was higher.The relative standard deviation(RSD)value of quality control plasma was 8.77%,and that of quality control plasma with the standard and pure water with standard were respectively 4.58% and 8.23%.The precisions of them met the requirement of detection(less than 20%).The recovery was 103.5% through used the above data,and the accuracy accorded with the requirements of quantitative detection(recovery was 103.5%).Conclusion:HPLC-MS/MS method is rapid and accurate in detecting H2S,which can accurately detect the content of serum H2S.This method has a series of advantages include fast,high throughput,high sensitivity and favorable stability,which contributes to conduct basic research of the content of serum H2S in the cellular pathways of human.