1.Antioxidation and chemical characterization of essential oil from Pelargonium graveolens.L'Her
Chunkai WANG ; Weijing QU ; Wei SUN ; Yuju LI
Chinese Traditional Patent Medicine 1992;0(06):-
AIM: To study medical effect of the antioxidation activity of essential oil from smell storusbill(Pelargonium graveolens,L'Her)(PLO) METHODS: Free radicals(O?_2、?OH and DPPH?)scavenging activities were investigated in different special chemical systems.Its anti-lipoperoxidantion activity was studied with MDA generation model in vitro.The effect of the hemolysis of cavy RBC induced by H_2O_2 was also studied.The components of PLO was identified by GC-FID. RESULTS: It was found that PLO showed higher anti-lipoperoxidantion on MDA generation spontaneously in homogenates of cavy heart,liver and kidney.There were significant differences on lipid peroxidant of the cavy liver homogenate induced by CCl_4 between control group and PLO.There were higher scavenging effect of the extracts of foliage on O?_2 and DPPH?PLO could strongly inhibit the hemolysis of cavy RBC induced by H_2O_2.The result of GC-FID and DPPH? scavenging activities indicated that the antioxidantion of citronellol was similar with PLO. CONCLUSION: PLO is a good antioxidation and citronellol is the main antioxidated substance in PLO.
2.Influence of prophylactic resection of orthotopic polycystic kidney disease on perioperative complications and surgical difficulty of renal transplantation in patients with ADPKD
Yichen ZHU ; Jingcheng LYU ; Chunkai DU ; Yuwen GUO ; Zhipeng WANG ; Jian ZHANG
International Journal of Surgery 2022;49(6):399-404,F3
Objective:To explore whether prophylactic resection of orthotopic polycystic kidney before allogeneic kidney transplantation can reduce the incidence and severity of perioperative complications in patients with end-stage renal disease due to autosomal dominant polycystic kidney disease (ADPKD), and reduce the difficulty of surgery.Methods:A retrospective case-control study method was used to recruit a total of 27 patients who were diagnosed with ADPKD and underwent allogeneic kidney transplantation in Beijing Friendship Hospital, Capital Medical University from January 2013 to January 2021, they were divided into prophylactic resection group ( n=19) and non-prophylactic resection group ( n=8) according to whether orthotopic polycystic kidney disease was prophylactic resection before transplantation. Patients in prophylactic resection group underwent orthotopic polycystic kidney resection before transplantation, while patients in non-prophylactic resection group didn′t. The indexes such as hemoglobin, platelet, albumin, left ventricular wall thickness, left ventricular ejection fraction, difficulty of kidney transplantation, average postoperative hospital stay, pain, and complication rate before kidney transplantation were analyzed and compared between the two groups. Measurement data were expressed as mean ± standard deviation ( ± s), and independent sample t-test was used for comparison between groups; Chi-square test was used for comparison of enumeration data between groups. Results:There was no significant difference in the general status of hemoglobin, platelets, albumin, left ventricular wall thickness, and left ventricular ejection fraction between the two groups before kidney transplantation ( P>0.05). However, the polycystic kidney volume [(2 409.8±1 899.8) cm 3] in the prophylactic resection group was greater than that in the non-prophylactic resection group [(1 340.2±290.6) cm 3], and the difference was statistically significant ( P=0.027). In terms of postoperative complications, 9 patients in the prophylactic resection group and 5 patients in the non-prophylactic resection group developed long-term low back pain or hematuria after transplantation, which were considered to be related to the unresected polycystic kidney disease, but the difference was not statistically significant ( P=0.678). Meanwhile, in both two groups, 3 patients underwent orthotopic polycystic nephrectomy after transplantation due to severe polycystic kidney complications. Although the incidence of complications in the prophylactic resection group (15.8%) was lower than that in the non-prophylactic resection group (37.5%), the difference was not statistically significant ( P=0.319). Conclusion:Prophylactic resection of orthotopic polycystic kidney before kidney transplantation can reduce the incidence and severity of polycystic kidney-related complications after transplantation, but has little effect on the operation time and intraoperative blood loss of kidney transplantation.
3.Application of three-dimensional image reconstruction technology based on 3D-slicer software in urology
Mengmeng ZHENG ; Chunkai DU ; Limin SHANG ; Lei ZHANG ; Wen SUN ; Zhipeng WANG ; Yichen ZHU ; Ye TIAN
International Journal of Surgery 2022;49(10):676-680,C2
Objective:To investigate the application value of three-dimensional image reconstruction technology based on 3D-slicer software in urology.Methods:The data of 36 patients with urinary tract diseases admitted to Beijing Friendship Hospital, Capital Medical University from May 2019 to December 2021 were retrospectively analyzed, including 20 males and 16 females; the median age was 53.50(41.75, 66.25) years. There were 10 relative kidney transplant donors, 12 cases with renal tumors, 6 cases with hydronephrosis and 8 patients with urinary calculi. The CT urography data of 36 cases were reconstructed into three-dimensional image models based on 3D-slicer software, and the morphology of the target tissue was measured.Results:In the urinary system model of 10 relative kidney transplant donors constructed in this study, the type of donor renal artery was single artery in 7 cases and accessory renal artery in 3 cases; In the three-dimensional model of 12 tumor kidneys, 4 tumors were located at the upper part of the kidney (2 near ventral and 2 near dorsal), 5 tumors were located at the middle part of the kidney (2 near ventral and 3 near dorsal), and 3 tumors were located at the lower part of the kidney near ventral. The average maximum diameter of the tumors was (27.3 ± 9.63) mm, and the tumor volume was (15.89 ± 5.93) cm 2. The study also successfully constructed a three-dimensional image model of the urinary system in 6 patients with hydronephrosis and 8 patients with urinary calculi (without hydronephrosis). Three-dimensional model image reconstructed by 3D-slicer software clearly showed the spatial structure of renal parenchyma, blood vessels, renal pelvis, calyces and ureter. The diameter, position and direction of ureters and blood vessels can be observed clearly based on the three-dimensional reconstruction model, and clinicians could also evaluate the location, shape, size and adjacent relationship with surrounding tissues of renal cysts, tumors, stones or other masses. Conclusion:3D-slicer software platform can assist clinicians to reconstruct the three-dimensional model of urinary system, which is worthy of further clinical application.
4.Application of 3D-slicer software to measure renal volume parameters in evaluating renal function of renal transplant donors
Mengmeng ZHENG ; Chunkai DU ; Limin SHANG ; Lei ZHANG ; Wen SUN ; Zhipeng WANG ; Yichen ZHU ; Ye TIAN
International Journal of Surgery 2023;50(12):823-828
Objective:To explore the application value of 3D-slicer software in measuring renal volume parameters of renal transplant donors in evaluating renal function.Methods:The data of 31 renal donors admitted to Beijing Friendship Hospital, Capital Medical University from October 2019 to September 2022 were retrospectively analyzed. Glomerular filtration rate (GFR) were measured by SPECT radioactive dynamic imaging, and renal cortex volume (RCV), renal parenchymal volume (RPV) were measured after 3D reconstruction of urinary enhanced CT based on 3D slicer software. The estimated GFR(eGFR) predicted by creatinine-based GFR estimation equations (C-G equation, modified and simplified MDRD equation) and volume-based GFR estimation equations (Herts equation, Choi equation). Different eGFR were calculated, and the correlation between kidney volume parameters, eGFR equations and measured GFR was analyzed. The deviation, accuracy and consistency between different equations eGFR and measured GFR were analyzed and compared. The measurement data of normal distribution were expressed as mean±standard deviation ( ± s), and t-test was used for inter-group comparison. Measurement data with non-normal distribution were represented by M( Q1, Q3), and non-parametric test was used for comparison between groups. Results:The correlation between different eGFR and measured GFR is poor, and the deviation is small, and with good accuracy and consistency. Except for the weak correlation between the Choi equation eGFR and measured GFR ( r=0.382, P=0.034), there was no significant correlation between eGFR by other equations and measured GFR ( P>0.05). Among them, the deviation between the Herts equation-eGFR and measured GFR was the smallest (0.30 mL·min -1·1.73 m -2), with a 10% coincidence rate (61.29%) and a 30% coincidence rate (96.77%), and the best consistency with measured GFR, with a consistency limit of -28.75 to 29.34 mL·min -1·1.73 m -2. Conclusion:Compared with the laboratory index formula method, the Herts equation has better prediction efficiency in estimating GFR, The measurement of renal volume parameters by 3D slicer software has a certain clinical value in evaluating the renal function of renal donors, which is worthy of further application.