1.Clinical efficacy of surgery for chronic subdural hematoma assisted by rigid neuroendoscope
Qing ZHU ; Zhongyong WANG ; Tan ZHANG ; Chungang DAI ; Liang XU ; Chao SUN ; Ailin CHEN ; Qing LAN
China Journal of Endoscopy 2017;23(6):52-57
Objective To discuss the clinical efficacy of surgery for chronic subdural hematoma assisted by rigid neuroendoscope and its surgical techniques. Methods Clinical data of 161 patients with chronic subdural hematoma from August 2009 to December 2015 was analyzed retrospectively. 74 of them experienced surgeries assisted by rigid neuroendoscope (endoscope group) and other 87 cases were operated without neuroendoscope (routine group) during the same period. Results Although there were significant difference in operative duration between the two groups, complications, ratio of total removal of hematoma after surgery, postoperative inpatient duration and recurrent rate of hematoma were more advantageous in endoscope group. The operative duration of endoscope group with (112.68 ± 34.86) min was longer than that of routine group with (74.11 ± 28.23) min (t = 7.75, P = 0.000), while the postoperative inpatient duration of endoscope group with (8.23 ± 2.01) d was shorter than that of another group with (10.79 ± 5.02) d (t = -4.12, P = 0.000). There were no surgical associated complications in endoscope group, but 1 patient in routine group experienced intracerebral hematoma of frontal lobe and associated aphemia. Total removal of hematoma was confirmed in endoscope group with 98.65% (73/74), which was higher than that in routine group with 86.21% (75/78) (χ2 = 8.34, P = 0.004). Hematoma recurrence was found in 16 cases of routine group (18.39%), but more superiority in endoscope group with 1.35% (χ2 = 12.29, P = 0.000). Outpatient follow-up was carried out in all patients from 6 to 38 months with an average duration of 30.06 months. In 17 cases with recurrent hematoma during follow-up, 15 of them were cured by a second surgery, and another 2 patients were cured by atorvastatin. Conclusion As a simple, safe and effective technique, the application of rigid neuroendoscope during surgery for chronic subdural hematoma is more advantage than routine surgery. A self-made suction with adjustable soft curved tip is suitable for such procedure.
2.Squamous Cell Carcinoma of Lung mixed with Malignant Lymphoma: 1 case report.
Deok Young CHOI ; Dong Suep SOHN ; Dai Yun CHO ; Ki Min YANG
The Korean Journal of Thoracic and Cardiovascular Surgery 1997;30(1):112-115
We have experienced a case of squamous cell carcinoma of lung mixed with malignant lymphoma. The patient was a 19-years-old male. He was a non-smoker. Right pneumonectomy was done. We could not find any evidences of metastasis. The postoperative course was uneventful. The tissue diagnosis was confirmed by immunohistochemical method. The lymphoma recurred at 3 months after operation and the patient was dead at 5 months after operation because of respiratory failure
Carcinoma, Squamous Cell*
;
Diagnosis
;
Humans
;
Lung*
;
Lymphoma*
;
Male
;
Neoplasm Metastasis
;
Pneumonectomy
;
Respiratory Insufficiency
3. Neuronavigation-assisted microsurgical operation via keyhole approaches for distal intracranial artery aneurysms
Chungang DAI ; Ailin CHEN ; Chao SUN ; Tao WU ; Qing ZHU ; Qing LAN
Chinese Journal of Microsurgery 2019;42(6):553-556
Objective:
To investigate the value of neuronavigation system in the keyhole microsurgical operation for distal intracranial artery aneurysms(DIAA).
Methods:
The clinical data of 16 cases with DIAA who were treated by via keyhole approaches, from January, 2013 to December, 2018, were analyzed retrospectively. Ten aneurysms located in anterior cerebral artery(ACA), 3 in posterior inferior cerebellum artery(PICA) and 3 in perforator artery(PA). The optimal skin incision and craniotomy were designed with assistence of neuronavigation system preoperatively, and lesions were located precisely under the guidance of neuronavigation system during microsurgery before clipping or resection. Angiography was performed before discharge, and clinic followed-up was conducted monthly till 6 months after surgery.
Results:
The systematic error of neuronavigation system ranged from 0.5 mm to 1.0 mm, with an average of 0.6 mm. All 16 aneurysms were explored and managed successfully with the guidance of neuronavigation system without aneurysm premature rupture nor neuronavigation-related complications. Absolute occlusion of all aneurysms was documented angiographically after surgery. Of all cases, 2 experienced shunt procedure due to delayed hydrocephalus. During 6 months follow-up period, all 16 cases recovered well.
Conclusion
Neuronavigation system can precisely locate the deep-seated DIAA, contribute to the preoperative planning of microsurgery via keyhole approaches and avoid evitable injury during excessive manipulation. The noninvasive, rapid and contrast-enhanced CT images of head was an ideal data source for the neuronavigation system.
4.Bilateral hypertensive intracerebral hemorrhage in basal ganglia: a case report
Yao WU ; Zhaoliang LI ; Dehong YANG ; Tao WU ; Ailin CHEN ; Chungang DAI ; Qing ZHU
Chinese Journal of Neurology 2023;56(2):187-190
Hypertensive intracerebral hemorrhage (ICH) is mostly single in basal ganglia, thalamus and pons. Simultaneous hemorrhage in other brain regions is relatively rare, accounting for only 5.6% of all hemorrhagic strokes, while bilateral symmetrical hemorrhage is extremely rare. A case of bilateral basal ganglia symmetrical hemorrhage is reported for clinical reference.
5.Safety of intraarterial microguidewire electrocoagulation in aneurysms: an animal experimental study
Tao WU ; Longjiang XU ; Wei XIA ; Zhigao JIN ; Yao WU ; Zhaoliang LI ; Dehong YANG ; Ailin CHEN ; Chungang DAI ; Qing ZHU
Chinese Journal of Neuromedicine 2022;21(5):443-449
Objective:To explore the efficacy and safety of intraarterial microguidewire electrocoagulation in arterial aneurysms.Methods:(1) SilverSpeed, a kind of microguidewire used in clinical intravascular treatment for intracranial aneurysms, was used to conduct in vitro electrolysis gas generation experiment with isolated arterial blood of anticoagulant New Zealand white rabbits as medium, and thrombus attachment on the surface of microguidewire was observed under scanning electron microscope. (2) Rabbit common carotid artery aneurysm models were established by using vein bag transplantation method, and divided into microguidewire electrocoagulation treatment groups ( n=40) and blank control group ( n=10). The number of closured tumor cavity and the quality of formed thrombus were observed after electrocoagulation simulation treatment with SilverSpeed microguidewire (charging at 6, 9, 12, 15, and 18 V voltage, respectively for 1, 3, 6, 9, 12, and 15 min). DSA was used to observe whether there was ruptured aneurysms or thrombosis of parent artery. Twelve h later, head MRI diffusion weighted sequence scan was performed to detect whether there were new cerebral ischemia foci in the distal cerebral blood supply area of the parent artery. DSA was performed again 6 months after surgery to observe whether the aneurysms recurred. Results:(1) Electrolytic gas generation experiment results showed that bubbles were generated after electrification of SilverSpeed microguidewire; the higher the voltage, the more severe the reaction. Scanning electron microscope showed that thrombus attached to the surface of the microguidewire after electrification in isolated blood; and the higher the voltage, the denser the thrombus. (2) Under the same charging time, the higher the voltage, the larger the number of closured tumor cavity in rabbits of the microguidewire electrocoagulation treatment groups. Under the same voltage, the longer the charging time, the better the quality of thrombosis. Ischemic events occurred only in the microguidewire electrocoagulation treatment group with voltage>9 V, and the charging duration was not associated with the incidence of embolic events. When the voltage was 15 V, 2 experimental rabbits died due to aneurysm rupture 3 min after electrification. When the voltage was 18 V, 4 experimental rabbits died of cardiac arrest 9 min after electrification, and another 2 rabbits died of aneurysm rupture 6 min after electrification.Conclusions:High voltage is the main cause of adverse events in the microguidewire electrocoagulation treatment of aneurysms. After setting the appropriate voltage, prolonging the electrification time can improve the electrocoagulation effect without increasing the safety risk.
6.The Effect of Epidural Pain Block After Thoracotomy.
Deok Young CHOI ; Kyung Jun WON ; Dong Suep SOHN ; Dai Yun CHO ; Ki Min YANG ; Young Cheol WOO ; Gill Hoi KOO
The Korean Journal of Thoracic and Cardiovascular Surgery 1997;30(8):809-814
Continuous epidural pain block with a local anesthetic agents is a commonly employed technique for pain relief after thoracotomy. In this study, we evaluated the effectiveness of the continuous epidural pain block in 19 patients undergoing elective lateral or posterolateral thoracotomy with control group(n=19) from November 1994 to July 1995. Epidural lidocaine and morphine mixtures were injected via an epidural catheter as a bolus after operation, and then bupivacaine and morphine mixtures were injected continuously following 5 or 6 days. The pain score, upper arm elevation(ROM score), and respiratory rate were significantly changed(P<0.05) from 30min after injection. The CO2 tension of arterial blood was decreased significantly(P<0.05) from 2hr after injection. The postoperative hospital days were decreased significantly(P<0.05). Side effects of the epidural pain block were urinary retention(n=10), urticaria(n=2) and a case of headache. There was no postoperative lung atelectasis. We conclude that the continuous epidural pain block is good for prevention of the postoperative lung complication and early recovery after thoracotomy.
Anesthesia, Epidural
;
Anesthetics
;
Arm
;
Bupivacaine
;
Catheters
;
Headache
;
Humans
;
Lidocaine
;
Lung
;
Morphine
;
Pulmonary Atelectasis
;
Respiratory Rate
;
Thoracotomy*
7.Neuroendoscopy in microsurgical clipping for ruptured posterior communicating artery aneurysms via keyhole approaches
Qinwei ZHOU ; Junjie CHEN ; Shaodong XI ; Ailin CHEN ; Chungang DAI ; Qing ZHU
Chinese Journal of Microsurgery 2022;45(3):304-309
Objective:To explore the value of application and manipulation technique of neuroendoscope in microsurgical clipping of ruptured posterior communicating artery(PCoA)aneurysms via keyhole approaches.Methods:From January 2018 to December 2020, the clinical data of 52 patients who received microsurgical clipping for ruptured via keyhole approach were retrospectively analysed. Forty-one patients had the intraoperative endoscopic monitoring. The supraorbital keyhole approach or pterional keyhole approach was applied based on the characteristics of the aneurysms. According to the in-surgery requirement, a 30° rigid neuroendoscope was used before and/or after clipping. All patients entered postoperative follow-up in outpatient clinic and were evaluated with the modified Rankin Scale(mRS).Results:All 52 patients had 52 ruptured PCoA aneurysms. Eighteen of the patients were treated via supraorbital keyhole approach and 34 via pterion keyhole approach. Pre-and post-clipping endoscopic observation were carried out in 12 cases and 29 only with post-clipping endoscopic observation. Residual aneurysmal neck was detected in 3 patients. Missed clipping of perforators was found in 2 patients and followed by proper adjustment of clips. All patients received follow-up angiographic examinations. Total obliteration of the aneurysm and an intact of internal carotid artery and PCoA were found in 41 patients by the intraoperative endoscopic observation. Two residual aneurysmal neck were detected in 11 patients without intraoperative endoscopic observation. After 11 to 45 months of follow-up, all patients had good recovery(mRS 0-1).Conclusion:It is a safe and effective method with endoscopic observation during microsurgical clipping procedure for ruptured PCoA aneurysms via keyhole approaches. It can effectively make up for the insufficient visual angle of microscope, realise the anatomical relationship between the aneurysm and adjacent structures, and avoid residual aneurysmal neck and an iatrogenic injury to the parent artery and perforators.