1.The Biotransformation of Atrazine and Influence Factors by Genetically Engineered Microorganism
Microbiology 1992;0(01):-
The co-metabolic carbon sources,dynamics and influence factors of atrazine biotransformation by genetically engineered microor- ganism(GEM)were investigated in the paper.The results showed that glucose was superior to acetate as co-metabolic carbon sources.The concentration of carbon sources affected little on atrazine transformation but much on GEM growth.The specific transformation rate(STR)of atrazine was influenced not by cell density of GEM but by atrazine concentration.Monod model was used to simulate atrazine transformation dynamics and the parameters were v_(max)=0.168/h and Ks=30.49 mg/L.When temperature reduced,STR decreased markedly.The trans- formation was efficient in weak alkaline condition and was inhibited in acidic condition.To some extent,salinity did not affect transformation activity of GEM.Co~(2+),Fe~(2+),Fe~(3+),and Zn~(2+) improved atrazine transformation,but Mn~(2+),Ni~(2+) and Cu~(2+) inhibited atrazine transforma- tion.The results also showed that there existed a direct correlation between adsorption and transformation of atrazine by GEM.
3.Bacterial Endotoxin Test for Nicardipine Hydrochloride Glucose Injection
Xia ZHENG ; Yumei ZHAO ; Chun LIU
China Pharmacy 1991;0(01):-
OBJECTIVE:To establish a method for the bacterial endotoxin test of nicardipine hydrochloride glucose injection.METHODS:The bacterial endotoxin test was carried out according to the bacterial endotoxin test in the addenda of China Pharmacopeia 2005 edition(second part).RESULTS:Nicardipine hydrochloride glucose injection showed interference on the bacterial endotoxin test when water was taken as solvent.The preliminary interference test and interference test revealed that using thinnerⅠas solvent,the sample injection in over 4-fold dilution had no interference on the bacterial endotoxin test.CONCLUSIONS:It is feasible for bacterial endotoxin test of nicardipine hydrochloride glucose injection be conducted in a limit value of 0.5 EU?mL-1.The bacterial endotoxin text can substitute pyrogen test in the detection of nicardipine hydrochloride glucose injection.
4.Expression of alpha-smooth muscle actin on experimental radiation nephropathy.
Dian-Ge LIU ; Bi-Cheng LIU ; Chun-Xia ZHANG
Chinese Journal of Pathology 2005;34(11):743-744
Actins
;
metabolism
;
Animals
;
Creatinine
;
blood
;
Kidney
;
pathology
;
Kidney Diseases
;
metabolism
;
pathology
;
Male
;
Radiation Injuries, Experimental
;
metabolism
;
pathology
;
Rats
;
Rats, Wistar
;
Vimentin
;
metabolism
5.Updates on comparative genomic hybridization study in rhabdomyosarcoma.
Dong-liang LI ; Chun-xia LIU ; Hong ZOU ; Feng LI
Chinese Journal of Pathology 2011;40(6):420-423
Cell Line, Tumor
;
Chromosome Aberrations
;
Comparative Genomic Hybridization
;
methods
;
Gene Amplification
;
Gene Dosage
;
Gene Expression
;
Humans
;
Receptor, Fibroblast Growth Factor, Type 1
;
genetics
;
metabolism
;
Rhabdomyosarcoma
;
genetics
;
metabolism
;
pathology
;
Rhabdomyosarcoma, Alveolar
;
genetics
;
metabolism
;
pathology
;
Rhabdomyosarcoma, Embryonal
;
genetics
;
metabolism
;
pathology
6.Application of role-play test in caring nursing service
Chun YANG ; Xingzhi HUANG ; Guixiu LIU ; Xia XU
Chinese Journal of Practical Nursing 2008;24(9):10-12
Objective To make nurses understand the essential factors of caring nursing service and satisfy the requirement of in-hospital patients. Methods To establish the plan of role-play test(RPT).The roles of patients were played by nurses. They experienced the caring requirement of patients, true feeling, the state of physiology and psychology, etc. Then we discuss and analyze the collected information to consummate measures of caring nufing service. Results The RPT deeped the nurses' understanding about essential factors of caring nursing service. The nursing quality and patients' satisfaction degree were improved compared with those of before(P<0.05).The nursing complaints and service quality were also increased. Conclusion Application of RPT proved to be an effective way to deepen the caring nursing service.
7.Influence of platform switching versus platform matching on the marginal bone resorption around im-plant:A Meta-analysis
Zihuan SUN ; Rong XIA ; Jiliang XU ; Xi MIN ; Chun LIU
Journal of Practical Stomatology 2015;(3):378-383
Objective:To evaluate the effects of platform switching and platform matching system on the marginal bone resorption a-round implant.Methods:Randomized controlled trials (RCTs)that compared marginal bone loss around platform-switched implants with platform matched prostheses were selected from PubMed,EMbase,CBM,CNKI and other electronic databases supplemented by hand search and retrospective collection of literature published or unpublished between 1 991 -201 4.The literature based on inclusion and exclusion criteria was screened by 2 revieweres independently,the quality of the included studies was evaluated,the data were extracted using RevMan 5.2 software for Meta-analysis.Results:1 4 studies with 1 331 implants were included.Meta-analysis showed that peri-implant bone resorption in the platform switching group was significantly less than that in the platform matching group[MD =-0.51 ,95% CI:(-0.72 -0.30),P <0.01 ].Subgroup analysis showed that the implant-abutment diameter difference >0.45 mm (unilateral)was more favorable to implant marginal bone preservation.Conclusion:The present data suggest that platform-switched technology is more conducive to implant bone preservation than platform-matched method.
8.The effects of different polishing instruments on the microstructure of different tipes of composite resins
Lei SUN ; Jiliang XU ; Yikai CHEN ; Chun LIU ; Rong XIA
Journal of Practical Stomatology 2014;(5):629-632
Objective:To evaluate the effect of different polishing instruments on the microstructure of composite resin.Methods:Specimens of 5 kinds of resins were randomly divided into three groups and were polished with Astropol(group A),Sof-Lex(group B) and Super-snap(group C)respectively(n=3 for each resin).Specimens of natural enamel surface were used as the controls(group D).The surface roughness(Ra)and microstructure of the specimens were evaluated by an atomic force microscope(AFM).Results:Ra value in group A was lower than that in group B(P=0.015);Z350 XT resin obtained the lowest Ra value among the 5 kinds of resin specimens(P<0.05).All of the resin specimens had similar average Ra after polishing procedure(P>0.05).Conclusion:Astropol polishing instrument is better than Sof-Lex;Z350 XT has better polish performance.The three polishing instruments are ef-fective in polishing the 5 composite resins.
9.Analysis of related factors of diabetes insipidus and disorders of sodium and water after surgery of sellar region tumor
Chunmei YIN ; Xiaoyan WANG ; Yingying DENG ; Yi LIU ; Chun XIA
Chinese Journal of Practical Nursing 2013;(3):45-47
Objective To explore the related factors of diabetes insipidus and disorders of sodium and water after surgery of sellar region tumor,and to find nursing strategy and improve the prognosis of sellar region tumors.Methods In this study,we retrospectively reviewed 150 cases of sellar region tumor from January 2005 to January 2011 in our department,including 67 cases of pituitary adenoma,53 cases of meningioma,30 cases of craniopharyngiona.Approaches were depended on the size and growing pattern of the tumors.Related factors of postoperative diabetes insipidus and disorders of sodium and water were analyzed.Results Large tumor size,the pathology of tumor,preoperative endocrine dysfunction,preoperative visual field and vision disorders and surgery approach were related to such complications.Conclusions Finding the related factors of these complications in patients and adopting care measures play an important role in improving the prognosis of sellar region tumors.
10.Integrated prenatal diagnosis and postnatal treatment for moderate and severe congenital diaphragmatic hernia
Bo XIA ; Gang YU ; Chun HONG ; Jing TANG ; Cuifen LIU
Chinese Journal of Perinatal Medicine 2015;18(11):843-847
Objective To share our experiences on integrated services in providing fetal diagnosis and postnatal treatment for congenital diaphragmatic hernia(CDH).Methods A retrospective analysis was conducted on 25 pregnancies diagnosed as CDH by both prenatal ultrasound and MRI in Maternal and Children Hospital of Guangdong Province from January 2012 to January 2014.All of the subjects received integral medical management including prenatal management (prenatal diagnosis and consultation), perinatal management (prenatal care and delivery) and neonatal treatment.Results Among the 25 CDH fetuses, 11 were mild, nine were moderate, and five were severe.One severe case, who was diagnosed at 26 gestational weeks, was aborted on demand of the mother.The other 24 cases continued their pregnancy and all delivered after 35 weeks including 13 cesarean sections (one due to twin pregnancy and 12 due to maternal demand) and 11 vaginal birth.The mean gestational age when CDH was diagnosed was (24.5 ± 3.5) weeks, and the 24 women delivered at an average of (37.5 ± 1.4) gestational weeks.The eleven mild cases accepted mask oxygenation.For those 13 moderate or severe CDH cases, all received dexamethasone to promote fetal lung maturity at 32 gestational weeks, seven were intubated before clamp the cord, and the other six did after.These 13 babies accepted high-frequency oscillation ventilation, with a median duration of 58 hours, and some of them treated with inhaled nitric oxide on requirement with a median duration of 52 hours.Except two cases died before operation, the rest 22 cases underwent neonatal surgery.One moderate case died at 48 hours after surgery due to pulmonary hypertension and respiratory failure.Another one severe case withdrew treatment at two months old.The other 20 infants recovered fully.Conclusions Integrated management including prenatal diagnosis and postnatal treatment, provides an effective and streamlined mode for diagnosis and treatment of CDH.Therefore,it might minimize potential medical risks.