1.Pediculosis Capitis Misdiagnosed as Seborrheic Dermatitis.
Jihoon KIM ; Haryeong RYU ; Chulhyun YUN ; Joonseok CHOI ; Jin Ok BAEK ; Joo Young ROH ; Jong Rok LEE
Korean Journal of Dermatology 2015;53(4):337-338
No abstract available.
Dermatitis, Seborrheic*
;
Lice Infestations*
2.Pediculosis Capitis Misdiagnosed as Seborrheic Dermatitis.
Jihoon KIM ; Haryeong RYU ; Chulhyun YUN ; Joonseok CHOI ; Jin Ok BAEK ; Joo Young ROH ; Jong Rok LEE
Korean Journal of Dermatology 2015;53(4):337-338
No abstract available.
Dermatitis, Seborrheic*
;
Lice Infestations*
3.A Novel Magnetic Resonance Quality Assurance Phantom (KMRP-4):Multi-Site Comparison With the American College of Radiology Phantom
Suchit KUMAR ; Jong-Min KIM ; Jang Gyu CHA ; Ji Young HWANG ; Seung Eun JUNG ; Chulhyun LEE ; Chang-Hyun OH
Investigative Magnetic Resonance Imaging 2023;27(1):10-20
Purpose:
To propose a novel standard magnetic resonance imaging (MRI) phantom, hereafter called the Korea Magnetic Resonance Phantom-4th edition (KMRP-4). Its related quality control (QC) assessment protocols and its comparison with the American College of Radiology (ACR) phantom and its QC assessment protocols.
Materials and Methods:
Internally, the KMRP-4 phantom is composed of cubic and triangular vessels, brain tissue structures, and a uniform region designed to facilitate a variety of QC protocols. Using magnetic resonance (MR) images of these structures, we quantitatively evaluated a total of 10 parameters, seven from those of existing ACR protocols (i.e., geometric accuracy, high-contrast spatial resolution, slice thickness accuracy, slice position accuracy, image intensity uniformity, percent signal ghosting, and low-contrast object detectability) and three additional parameters for evaluating vessel conspicuity, brain tissue contrast, and signal-to-noise ratio (SNR) introduced in the KMRP-4 protocols. Twentytwo MRI systems of 0.32–3.0 T static magnetic field strength were tested using both ACR and KMRP-4 phantoms. Mann–Whitney U-tests were performed on the seven evaluation items of the ACR method to compare KMRP-4 and ACR methods.
Results:
The results of Mann–Whitney U-test demonstrated that p-values were more than 0.05 for all seven items that could be assessed with both ACR and KMRP-4, indicating similar results between the two methods. Additionally, assessments of vessel conspicuity, brain tissue contrast, and SNR using the KMRP-4 method demonstrated utility of the KMRP-4 phantom.
Conclusion
A novel standard phantom and related QC methods were developed to perform objective, observer-independent, and semi-automatic QC tests. Quantitative comparisons of MR images with KMPR-4 and ACR phantoms were performed. Results demonstrated the utility of the newly proposed KMRP-4 phantom and its related QC methods.
4.Manganese-Enhanced Magnetic Resonance Imaging of the Spinal Cord in Rats.
Myeoung Hoon CHA ; Chulhyun LEE ; Jee Hyun CHO ; Myung Ae CHUNG ; Jin Hun SOHN ; Chaejoon CHEONG ; Hye Jung LEE ; Bae Hwan LEE
Experimental Neurobiology 2009;18(1):57-61
Manganese-enhanced magnetic resonance imaging (MEMRI) offers a novel neuroimaging method in visualizing the activity patterns of neural circuits. MEMRI is using the divalent manganese ion, which has been used as a cellular contrast agent. The present study was conducted to determine the contrast-enhancing effects of manganese ion administered into the spinal cord of rats. Manganese ion was administered into the spinal cord by lumbar puncture. Ex vivo magnetic resonance images were obtained at 6, 12, 24, and 48 hours after manganese ion injection. Although the highly contrasted images were not observed 6 or 12 hr after manganese injection, the distinctive manganese-enhanced images began to appear at 24 hours after manganese ion injection. These results suggest that the gray matter is the foci of intense paramagnetic signals and MEMRI may provide an effective technique to visualize the activity-dependent patterns in the spinal cord.
Animals
;
Magnetic Resonance Imaging
;
Magnetic Resonance Spectroscopy
;
Magnetics
;
Magnets
;
Manganese
;
Neuroimaging
;
Rats
;
Spinal Cord
;
Spinal Puncture
5.T1-Based MR Temperature Monitoring with RF Field Change Correction at 7.0T
Jong Min KIM ; Chulhyun LEE ; Seong Dae HONG ; Jeong Hee KIM ; Kyung SUN ; Chang Hyun OH
Investigative Magnetic Resonance Imaging 2018;22(4):218-228
PURPOSE: The objective of this study is to determine the effect of physical changes on MR temperature imaging at 7.0T and to examine proton-resonance-frequency related changes of MR phase images and T1 related changes of MR magnitude images, which are obtained for MR thermometry at various magnetic field strengths. MATERIALS AND METHODS: An MR-compatible capacitive-coupled radio-frequency hyperthermia system was implemented for heating a phantom and swine muscle tissue, which can be used for both 7.0T and 3.0T MRI. To determine the effect of flip angle correction on T1-based MR thermometry, proton resonance frequency, apparent T1, actual flip angle, and T1 images were obtained. For this purpose, three types of imaging sequences are used, namely, T1-weighted fast field echo with variable flip angle method, dual repetition time method, and variable flip angle method with radio-frequency field nonuniformity correction. RESULTS: Signal-to-noise ratio of the proton resonance frequency shift-based temperature images obtained at 7.0T was five-fold higher than that at 3.0T. The T1 value increases with increasing temperature at both 3.0T and 7.0T. However, temperature measurement using apparent T1-based MR thermometry results in bias and error because B1 varies with temperature. After correcting for the effect of B1 changes, our experimental results confirmed that the calculated T1 increases with increasing temperature both at 3.0T and 7.0T. CONCLUSION: This study suggests that the temperature-induced flip angle variations need to be considered for accurate temperature measurements in T1-based MR thermometry.
Bias (Epidemiology)
;
Fever
;
Heating
;
Hot Temperature
;
Magnetic Fields
;
Magnetic Resonance Imaging
;
Methods
;
Protons
;
Signal-To-Noise Ratio
;
Swine
;
Thermometry
6.The 2nd Meeting of National Control Laboratories for Vaccines and Biologicals in the Western Pacific.
Hokyung OH ; Jinho SHIN ; Chung Keel LEE ; Masaki OCHIAI ; Kiyoko NOJIMA ; Chang Kweng LIM ; Sanj RAUT ; Irene LISOVSKY ; Stella WILLIAMS ; Ki Young YOO ; Dong Yeop SHIN ; Manabu ATO ; Qiang YE ; Kiwon HAN ; Chulhyun LEE ; Naery LEE ; Ji Young HONG ; Kikyung JUNG ; Pham VAN HUNG ; Jayoung JEONG
Osong Public Health and Research Perspectives 2018;9(3):133-139
The Second Meeting of the National Control Laboratories for Vaccines and Biologicals in the Western Pacific, was jointly organized by the National Institute of Food and Drug Safety Evaluation of the Ministry of Food and Drug Safety in the Republic of Korea, and by the World Health Organization Regional Office for the Western Pacific. In the National Lot Release Systems session countries including Canada, China, Japan, Malaysia, Vietnam, and the Republic of Korea, all shared information on their current Lot Release Systems, including current practices and developments in risk-based official lot release of vaccines. In the session on Quality Control of Blood Products, experts from the National Institute for Biological Standards and Control shared quality control and research results for; blood coagulation factor VIII products, and the measurement of procoagulant activity in immunoglobulin products. Representatives from Japan proposed a regional collaborative study to test aggregated immunoglobulin free from complement activity. A cell-based Japanese encephalitis vaccine potency assay was proposed by representatives from Korea and they also called for voluntary participation of other National Control Laboratories in a collaborative study, on the first Korean Gloydius anti-venom standard. Participants agreed in general to continue communicating, and coordinate presentation of the study results.
Blood Coagulation Factors
;
Canada
;
China
;
Complement System Proteins
;
Encephalitis, Japanese
;
Factor VIII
;
Immunoglobulins
;
Japan
;
Korea
;
Malaysia
;
Quality Control
;
Republic of Korea
;
Vaccine Potency
;
Vaccines*
;
Vietnam
;
World Health Organization