1.The Design of the control system of radiating therapeutic instrument
Chinese Medical Equipment Journal 1989;0(03):-
The control system of radiating therapeutic instrument, powerful and reliable, is designed with the new chips of P89LPC669 and MAX669. Its hardware organization, system function and software framework are introduced in this paper.
2.Application of Fussy-PID Control in Freeze-Drier
Chuanwei HUANG ; Xiaohui LIANG ; Jianhua JIANG
Chinese Medical Equipment Journal 1989;0(04):-
Objective To improve the freeze-dryer shelf temperature control effect.Methods The fuzzy-PID control algorithm that's adjusting the PID parameters in real-time in the control process,was adopted to control the shelf temperature,expecting to adapt the changing of process parameters of shelf.Results In the process of freeze-drying temperature control shelves,the shelf temperature static performance and dynamic performance were improved,and the effect of shelf temperature control was archived satisfyingly.Conclusion In the freeze-drying process,the process parameters of shelf are changed along with the drying time and the working environment.The conventional PID control is difficult to obtain satisfactory results.The fuzzy-PID controller,which can adjust PID parameters on real-time in the controlling process,be used in the shelf temperature control,and the result is satisfied.
3.Design of a high speed data acquisition system for biological mass spectrometers
Hui WANG ; Xiaohui LIANG ; Chuanwei HUANG
Military Medical Sciences 2017;41(6):510-515
Objective To develop a high-speed data acquisition system with sampling frequency of 2 GHz to meet the requirement of accurate measurement of flight time.Methods The ALTERA STRATIX Ⅲ series FPGA was used as the main control chip, matching with high-performance ADC chip with sampling frequency up to 2 GHz and sampling accuracy up to 12 bit, while extending 512 MB DDR3 SDRAM for data cache and exchanging data with the host computer through Gigabit Ethernet.In addition, a variety of PCB wiring methods were used to effectively ensure the signal integrity.Results The 250 MHz sine signal was input into the data acquisition board with 2 GHz sampling frequency,by analyzing and calculating the sampling data,acquired the following performance index of SNR=44.6639 and ENOB=7.1.Conclusion This high-speed data acquisition system based on ADC technology is a fast and reliable path and method for the measurement and analysis of biological mass spectrometry data.
4.Development and Application of Clinical Pharmacy Information Management System Software
Ping HUANG ; Chuanwei XIN ; Xiuli YANG ; Yong YUAN
China Pharmacy 2001;0(07):-
OBJECTIVE: To develop a set of consummated comprehensive application platform that meets the actual demand so as to promote hospital treatment level and pharmaceutical care quality.METHODS: The protocol and standard meeting the international standard was adopted for system design.The currently popular combination tools(Apache+PHP+MySQL) set was developed and an open information resources management system and multi-structured architecture were established.RESULTS & CONCLUSIONS: This system is practical,advanced and safe and it is composed of 5 modules: drug inquiry system,rational drug use system,management on adverse drug reactions,pharmacy administrative management and network management.The system can not only guarantee the compatibility and the expandability of system,but also meet the needs of the development of hospital pharmacy and effectively enhance the rational drug use.
5.Determination of multiple optical parameters of red blood cell suspension
Meihua LI ; Chuanwei HUANG ; Yuanming FENG ; Xinhua HU ; Xiaohui LIANG
Military Medical Sciences 2016;40(8):680-685
Objective To develop a measurement method for determination of optical parameters of a red blood cell ( RBC) suspension based on the measurement of spatial scattered light signals without using an integrating sphere.Methods Multiple independent photoelectric sensors and light intensity modulation were used to obtain the measured values of diffuse reflectance,diffuse transmittance and collimated transmittance.The measured data results were imported into a Monte Carlo simulation based RTE to inversely determine the absorption coefficient, scattering coefficient and anisotropy factor of the measured sample using a new perturbation method.Results The described measurement method was applied to determine the optical parameters of a polystyrene microsphere suspension with a mean diameter of 2.6μm,and the results were essen-tially consistent with the calculated optical parameters by Mie code.Then, the RBC suspension was used for testing optical parameters,and the results were basically consistent with the parameters in the literature.Conclusion The system based on the measurement of spatial scattered light signals without using an integrating sphere will provide a quick and accurate approach for quantitative analysis of free hemoglobins and RBC suspensions.
6.Design of a portable oxygen supply respirator
Siwei LI ; Yanfang ZHENG ; Xiaowei FAN ; Chuanwei HUANG ; Xue LIU ; Jie WANG
Military Medical Sciences 2016;40(9):742-745
Objective To design a portable respirator that can facilitate both cardiopulmonary resuscitation and auxiliary oxygen inhalation.Methods Positive pressure design as well as pneumatically powered and controlled design were adopted for this respirator.Theoretical calculation of key components was carried out.The virtual prototype was established and the structure checked using the three dimensional design software Solidedge.Finally,the prototype was processed,assembled and tested.Results Experimental tests proved that the designed respirator was capable of cardiopulmonary resuscitation and auxiliary oxygen inhalation when oxygen supply pressure reached 3 -5.5 bar.It could achieve the expected technical indicators,such as the oxygen flow rate that was between 10 and 12 L/min.Conclusion The portable oxygen supply respirator has the advantages of a small size,light weight,simple operation,and automatic power supply.It has broad prospects of application.
7.Design and implementation of auto-control system for high-throughput and multi-channel DNA synthesis
Xiaohui LIANG ; Chuanwei HUANG ; Jian GUO ; Xiaojiang XIONG ; Xiaoning WANG ; Guiqiang WANG ; Xiaowei FAN
Military Medical Sciences 2015;(8):571-576
Objective To establish an auto-control system for high-throughput and multi-channel DNA synthesis which can simultaneously and quickly synthesize up to 96 different oligonucleotides in a 96-well microtiter format.Methods The PLC and its extended modules is used as the main-control unit, which executes the DNA automatic synthesis process according to the synthesis sequences and steps set by the user,and the manual injecting reagent etc.And the configuration software and VC6.0 were used for programming the man-machine interface sofeware to set synthesis parameters, position calibration,flux calibration data etc, and communicated with PLC.Results The synthesis application of about 150 000 DNA chains has proved that the synthesis cycle time for 96 couplings was 4 min,the average coupling efficiency was 99%across the entire 96-well plate,the monomer reagent usage was reduced by 50 percent,and the synthesis configuration was more flexible.Conclusion A reliable and simple auto-control system is provided for parallel synthesis of 96-channel oligonucleotide chains,which can meet the demands of high-throughput and multi-channel DNA synthesis.
8.Values of glycosylated hemoglobin in screening for patients with prediabetic state in Guangzhou region
Shaoguo WU ; Yujun HUANG ; Bo CHEN ; Zhihai LI ; Bei BAO ; Chuanwei DUAN ; Lie YANG ; Changqing ZHU ; Wuanmei LI ; Yan SUN
International Journal of Laboratory Medicine 2014;(9):1114-1115,1118
Objective To study the values of glycosylated hemoglobin in screening for patients with prediabetic state in Guang-zhou region .Methods 525 Guangzhou people who had accepted health examination were enrolled and were subjected to oral glucose tolerance test(OGTT) .BIO-RAD D-10 automatic glycosylated hemoglobin analyzer was employed to detect their glycosylated he-moglobin A1c(GHbA1c) .OGTT results were served as diagnostic criteria ,Receiver operator characteristic (ROC) curve analysis was performed to obtain the optimal threshold of GHbA1c in diagnosing impaired glucose regulation (IGR) .Results The optimal threshold of GHbA1c in diagnosing IGR was 5 .95% .The sensitivities of GHbA1c≥5 .95% and GHbA1c≥5 .7% in diagnosing IGR were 53 .3% and 84 .8% ,respectively ,while their specificities were 72 .8% and 31 .0% ,respectively .The difference of sensitivity between GHbA1c≥5 .95% combined with FPG≥5 .6 mmol/L and GHbA1c≥5 .7% alone in diagnosing IGR showed no statistical significance(P= 0 .406) ,while the specificity increased obviously (P= 0 .000) .Conclusion The criteria of GHbA1c≥5 .7% can be used for prediabetic state screening but not for diagnosis .GHbA1c≥5 .95% combined with FPG≥5 .6 mmol/L can be used effectively for prediabetic state screening in Guangzhou people .
9.Analysis on the diagnosis and treatment of necrotizing fasciitis complicated with sepsis
Chuanwei SUN ; Huining BIAN ; Hongmin LUO ; Shaoyi ZHENG ; Bing XIONG ; Zu'an LIU ; Zhifeng HUANG ; Lianghua MA ; Hanhua LI ; Wen LAI
Chinese Critical Care Medicine 2021;33(4):483-486
Objective:To recognize the characteristics of necrotizing fasciitis patients complicated with sepsis and summarize the experience the treatment.Methods:A retrospective study was conducted. The clinical data of 57 patients with necrotizing fasciitis complicated with sepsis admitted to Guangdong Provincial People's Hospital from July 2009 to December 2019 was analyzed by collecting such factors as gender, age, complications, infection sites, pathogens, surgery information, treatment options and outcome. The patients were divided into debridement group ( n = 14) and control group ( n = 43) according to whether the debridement was completed within 48 hours of admission, and the mortality during hospitalization between the two groups was compared. A telephone follow-up had been done to record the long-term outcome of these patients. Results:Among 57 patients with necrotizing fasciitis complicated with sepsis, there were 43 males and 14 females with the average age of (57.9±12.1) years old. Most of the underlying diseases were diabetes mellitus (70.17%), other diseases included hypertension (8.77%), tumor chemotherapy (7.02%), liver disease (hepatitis, cirrhosis, 7.02%), coronary artery heart disease (3.51%), systemic lupus erythematosus (3.51%), etc. Most of the infection site was lower limbs (71.93%). There were 78 pathogens cultured in 57 patients, in which 52 were non-drug resistant bacteria (66.67%), and 26 were drug resistant bacteria (33.33%). There were 40 Gram positive (G +) bacteria (51.28%), 29 Gram negative (G -) bacteria (37.18%), 8 fungi (10.26%) and 1 mixed bacteria (1.28%). Finally, of 57 patients, 46 patients were cured, and 11 patients died with hospital mortality of 19.30%. Among 57 patients, the hospital mortality in the debridement group was significantly lower than that in the control group [0% (0/14) vs. 25.58% (11/43), P < 0.05]. Among the 46 cured patients, 11 had accepted amputations, accounting for 23.91%. In December 2020, 43 patients who were cured (3 patients were lost to follow-up) were followed up by telephone. Twenty-three patients were completely self-care, 9 patients were partly self-care, 8 patients were completely unable to take care of themselves, and 3 patients died. Conclusions:Necrotizing fasciitis with sepsis mostly occurs in people with weakened immunity, and has a high mortality and disability rate. Early identification and active surgical debridement may be the key to improve the treatment effect.
10.Protective effects of valproic acid on gut barrier function after major burn injury and its mechanism
Hongmin LUO ; Sen HU ; Huining BIAN ; Shaoyi ZHENG ; Bing XIONG ; Zhifeng HUANG ; Zu'an LIU ; Chuanwei SUN ; Lianghua MA ; Hanhua LI ; Wen YU ; Minghua DU ; Huada CHEN ; Wen LAI
Chinese Critical Care Medicine 2017;29(3):221-227
Objective To investigate the potential protective effects of valproic acid (VPA) on gut barrier function after major burn injury in rats and its mechanism.Methods Forty male Sprague-Dawley (SD) rats were divided into sham + normal saline (NS),sham + VPA,scald + NS,and scald + VPA groups,with 10 rats in each group.Rat with 55% total body surface area (TBSA) third-degree severe-bums model was reproduced by immersing into 80 ℃ water,and the rats in sham groups were given sham-bums by immersing into 37 ℃ water.The rats after severebums were immediately treated with 0.25 mL of 300 mg/kg VPA or NS by subcutaneous injection.Rats were sacrificed at 2 hours and 6 hours after injury,and abdominal aortic blood and ileal tissue were harvested.The levels of vascular endothelial growth factor (VEGF) were determined by enzyme-linked immunosorbent assay (ELISA).The intestinal permeability was evaluated by fluorescein isothiocyanate-dextran (FITC-dextran) determination.The histomorphological changes in gut barrier were evaluated by Chiu grading system.Levels of acetylated lysine at the ninth position of histone 3 protein (Ac-H3K9),hypoxia-inducible factor 1α (HIF-1α),zona occludens 1 (ZO-1) and myosin light chain kinase (MLCK) were determined by immunofluorescence staining and Western Blot.Results Compared with sham + NS group,rats in scald + NS group showed intestinal mucosal damage 2 hours after bum injury,as well as increased mucosal permeability,protein expression levels of HIF-1 α,VEGF,MLCK,and lowered levels of AC-H3K9 and ZO-1.These changes were much more prominent at 6 hours after injury.VPA treatment significantly attenuated the bum-induced intestinal damage.Compared with scald + NS group,the protective effects in scald + VPA group was not evident at 2 hours after injury;however,intestinal damage was much less severe at 6 hours after injury (Chiu score:2.03 ± 0.27 vs.3.12 ± 0.15),intestinal permeability was significantly decreased [FITC-dextran (μg/L):709 ± 76 vs.1138 ± 75],histone acetylation was enhanced [Ac-H3K9 (gray value):1.55 ± 0.12 vs.0.48±0.12],ZO-1 degradation was significantly inhibited (gray value:0.69 ± 0.12 vs.0.43 ± 0.16),the protein expression levels of VEGF and MLCK were significantly down-regulated [VEGF (ng/mg):51.7±3.7 vs.71.2±4.3,MLCK (gray value):1.98±0.20 vs.2.80±0.24],while the HIF-1 α protein expression levels were significantly reduced at both 2 hours and 6 hours after injury (gray value:2.50±0.39 vs.3.88±0.42 at 2 hours,1.83±0.42 vs.4.42±0.41 at 6 hours,all P < 0.05).Conclusions Severe bum injury can induce histone deacetylation,ZO-1 degradation and intestinal barrier dysfunction.VPA can improve the levels of histone acetylation and ZO-1,and protect intestinal epithelial barrier function.These may probably be mediated through inhibiting HIF-1α and its downstream gene VEGF and MLCK.