1.Meta analysis of unipolar versus bipolar hemiarthroplasty for elderly patients with femoral neck fracture
Jiangtao CHEN ; Jianjun HUO ; Chuanhui XUN ; Li CAO ; Xinghua SONG ; Zheng TIAN
Chinese Journal of Trauma 2014;30(9):917-923
Objective To evaluate the effect of unipolar versus bipolar hemiarthroplasty for treatment of femoral neck fracture in the elderly Methods Related randomized controlled trials (RCTs) and quasi-randomized controlled trials (qRCTs) were searched from computerized databases MEDLINE,EMBASE,Cochrane Library,and CBM disc.Additional studies were identified through hand searches of 10 domestic journals.Time period of the search was from 1966 to June 2012.RevMan 4.2.8 software was used for data analysis.Results A total of 7 RCTs and 3 qRCTs were included.In this meta analysis,bipolar hemiarthroplasty was associated with better hip function compared with unipolar hemiarthroplasty at postoperative 6 months (RR =0.74,95% CI0.62-0.88,P < 0.01).However,the two procedures revealed no significant differences in terms of postoperative one-year dislocation rate (RR =1.01,95% CI0.54-1.89,P > 0.05),reoperation rate (RR =1.13,95% CI 0.74-1.72,P > 0.05),major complication incidence (except for dislocation) (RR =1.27,95% CI 0.74-2.18,P > 0.05),and postoperative 2-year mortality (RR1.16,95% CI 0.73-1.87,P > 0.05).Conclusion Bipolar hemiarthroplasty is preferable to unipolar hemiarthroplasty for hip function improvement,but postoperative one-year dislocation rate,reoperation rate,major complication incidence (except for dislocation),and postoperative twoyear mortality are similar for the two procedures.
2.Application of a new V-shaped forearm flap in reconstruction of buccal cancer
Shengwei HAN ; Hao LI ; Rui LIU ; Chuanhui SONG ; Xiteng YIN ; Zhe LIU ; Yi LIANG ; Wei HAN
Chinese Journal of Microsurgery 2021;44(3):279-282
Objective:To design a new V-shaped forearm flap and to investigate the possibility of direct donor site closure and its value in the reconstruction of soft tissue defect after resection of buccal carcinoma.Methods:The new V-shaped forearm flap technique was applied in 10 patients with buccal carcinoma from October, 2018 to September, 2019. There were 6 males and 4 females aged from 35 to 63 years (48.3 years in average). Flap size ranged from 3.0 cm×5.0 cm to 4.0 cm×6.0 cm. Wound healing and the appearance forearm were recorded and evaluated three months after the surgery. Radial deviation angle, wrist flexion, ulnar deviation and dorsal extension were measured and calculated 3 months after the surgery. The wrist function was evaluated according to the Gartland-Werley scale. The recovery of wrist function was evaluated by comparing with the preoperative data.Results:Forearm donor sites were successfully closed without skin grafting in all 10 patients. Skin ischemia caused by excessive tension was observed at the incision edge in 3 patients, therefore leading to skin exfoliation and pigment loss without affecting wound healing. All patients were presented a cosmetic outcome during the follow-up period. No scar hyperplasia was observed. No significant difference was observed in perioperative wrist flexion angle, dorsal extension angle, radial deviation angle, ulnar deviation angle ( P>0.05)[data before surgery were (57.8±1.3) °, (58.4±0.7) °, (18.2±0.5) °, (28.5±1.1) ° respectively, and data 3 months after surgery were (53.2±2.1) °, (55.3±1.8) °, (16.4±0.4) °, (25.4±1.4) ° respectively]; Excellent and good rate of Gartland-Werley wrist score before and after surgery were both 100%. Conclusion:The new V-shaped free forearm flap can directly close small to medium forearm flap donor site. This method could avoid the trauma and complications of traditional free skin graft. The postoperative appearance on donor site is satisfactory and will not have adverse effects on wrist function. The new V-shaped free forearm flap is a novel method for repair of the defect of soft tissue defect after buccal cancer and it is worth to be applied in clinical practice.
3.Development and clinical evaluation of an equipment with artificial intelligence real-time assistance in detection of gastrointestinal protruding lesions under endoscopy
Zhiyin HUANG ; Jingsun JIANG ; Qiongying ZHANG ; Qinghua TAN ; Hui GONG ; Linjie GUO ; Chuanhui LI ; Jiang DU ; Huan TONG ; Bing HU ; Jie SONG ; Chengwei TANG ; Jing LI ; Ling LIU
Chinese Journal of Digestion 2020;40(11):745-750
Objective:To develop an diagnostic equipment with artificial intelligence (AI) real-time assistance under endoscopy (endoscopic AI equipment) for the detection of gastrointestinal protruding lesions, and to evaluate its performance and safety.Methods:From January to December 2017, at Endoscopy Center of West China Hospital, Sichuan University, the endoscopic images of individuals who underwent routine gastroscopy and colonoscopy were collected. The model was established based on convolutional neural network and the endoscopic AI equipment was developed. From June to December 2019, a prospective, single center, blinded and parallel controlled study was conducted to compare the differences in evaluation of protruding lesions of the same patient under gastroscopy or colonoscopy between endoscopist and the endoscopic AI equipment and to evaluated the impact of lesion size (lesions <5 mm and ≥5 mm) on the detection of endoscopic AI equipment. The main outcome measure was the detection time difference in reporting the protruding lesion between endoscopic AI equipment and endoscopist; and the secondary indicator was the accuracy of endoscopic AI equipment in detecting the protruding lesion. Wilcoxon rank sum test and chi-square test were used for statistical analysis.Results:A total of 71 582 white light endoscopy images were used for endoscopic AI equipment training, which included 41 376 images of protruding lesions. The endoscopic AI equipment was successfully developed and obtained the registration certificate of medical devices of the People′s Republic of China (Sichuan Instrument Standard, 20202060049). The accuracy, sensitivity, and specificity of endoscopic AI equipment in detecting protruding lesions were 96.4%, 95.1% and 92.8%, respectively. The detection time of each protruding lesions under gastroscopy of endoscopic AI equipment was 1.524 seconds faster than that of endoscopist; but the detection time of each protruding lesions under colonoscopy was 0.070 seconds slower than that of endoscopist, and the differences were statistically significant ( Z=-5.505 and -4.394, both P<0.01). The detection time of each protruding lesions under gastroscopy or colonoscopy of endoscopic AI equipment was not inferior to that of endoscopist. The detection rate of protruding lesions under colonoscopy by endoscopic AI equipment was 89.9% (249/277) and the sensitivity was 89.9%; the detection rate of protruding lesions under colonoscopy was 87.0% (450/517) and the sensitivity was 86.9%. There were no statistically significant differences in the detection time difference, sensitivity and missed diagnostic rate between the lesions <5 mm and ≥5 mm detected by endoscopic AI equipment under gastroscopy (all P>0.05). The sensitivity of endoscopic AI equipment in detecting the lesions ≥5 mm under colonoscopy was higher than that of lesions <5 mm (96.8% vs. 84.9%), and the missed diagnostic rate was lower than that of lesions <5 mm (3.2%, 3/94 vs. 15.1%, 61/405), and the differences were statistically significant ( χ2=9.615 and 9.612, both P=0.002). No adverse events on patients and medical staffs occurred, and there were no cases of equipment electricity leakage, and abnormal work reported during the use of endoscopic AI equipment. Conclusions:The endoscopic AI equipment can report the protruding lesions simultaneously with endoscopists, and the accuracy is close to 90%, which is expected to be a practical assistant for endoscopists to avoid missed detection of protruding lesions.
4.Upper left lung cancer with congenital complete left pericardial defect: A case report
Chuanhui DUAN ; Dongliang YU ; Jianwen XIONG ; Wenxiong ZHANG ; Yu' ; ang MAO ; Qian SONG ; Yiping WEI
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2022;29(02):272-274
A 54-year-old asymptomatic man underwent a video-assisted thoracoscopic left pneumonectomy for squamous-cell carcinoma. During the surgery, a complete left pericardial defect was unexpectedly discovered, but no special intervention was made. The preoperative chest CT was reciewed, which showed the heart extended unusually to the left, but the left pericardial defect was not evident. The operation time was 204 min and the patient was discharged from hospital upon recovery 9 days after the surgery. The pathological result indicated moderately differentiated squamous-cell carcinoma (T2N1M0, stage ⅡB), and metastasis was found in the parabronchial lymph nodes (3/5). The patient did not receive chemotherapy after the surgery, and there was no signs of recurrence 6 months after the surgery. Complete pericardial defects usually do not endanger the lives of patients, and if the patient is asymptomatic, pneumonectomy is feasible.