1.Analysis of lower neck setup errors and planning target margin by CBCT for breast cancer radiation with breast bracket immobilized
Chuanfeng WU ; Jinchang WU ; Ke GU ; Cheng LI ; Danqing SHEN ; Rui HU
Chinese Journal of Radiological Medicine and Protection 2016;36(10):753-756
Objective To evaluate the setup errors for lower neck with cone beam CT (CBCT) in breast cancer patients immobilized by breast bracket,and to probe the margins from supraclavicular clinical target volume (CTV) in 3 directions.Methods A total of 14 breast cancer patients with supraclavicular lymph node radiation were enrolled.All patients were immobilized by breast bracket,and each patient would undergo CBCT at the first,tenth and twentieth treatment after positioning,respectively.Then these CBCT images were registered to the planning CT to determine setup errors in translational and rotational direction,and evaluated correlation between them.At last,CTV margins were calculated from the systenatic and random errors.Results The setup errors on x (left-ring),y (superior-inferior),z (anterior-posterior) translational directions were (2.89 ±.2.52),(3.96 ±2.97),(4.21 ±2.24) mm and on θ (pitch degree),φ (roll degree),Ψ (yaw degree) rotational direction were (2.38 ± 1.97)°,(1.60±1.63) °,(1.91 ±1.54)°,respectively.The margins from CTV were 8.08,8.13,6.30mminx,y and z direction.On y and z directions translational errors were correlated significantly with φ and Ψ degree rotational errors(Pearson =-0.515,-0.509,P < 0.05).In inter-fraction only on z direction the setup changes were considered as correlative with Ψ degree (Pearson =-0.583,P < 0.05).Conclusions For supraclavicular region irradiation breast cancer patients immobilized with breast bracket,the margins from CTV were recommended as not less than 8.08,8.13,6.30 mm in x,y,z directions,respectively.The position immobilized method and the positioning workflow should be further improved in order to reduce the influence of the neck rotational on setup errors.
2.Effect of curcumin on expression of MMP-2 and MMP-9 in spinal dorsal horn and dorsal root ganglion of rats with type 2 diabetic neuropathic pain
Shaosheng WU ; Chuanfeng SUN ; Hong CAO ; Jiajia LI ; Xiaoting SHI ; Jun LI
Chinese Journal of Anesthesiology 2014;34(11):1339-1342
Objective To evaluate the effect of curcumin on the expression of MMP-2 and MMP-9 in the spinal dorsal horn and dorsal root ganglion (DRG) of rats with type 2 diabetic neuropathic pain (DNP).Methods Type 2 diabetes mellitus was induced by high-fat and high-sucrose diet and intraperitoneal streptozotocin 35 mg/kg,and confirmed by fasting blood glucose level ≥ 16.7 mmol/L in male Sprague-Dawley rats.Type 2 DNP was confirmed by the mechanical paw withdrawal threshold (MWT) and thermal paw withdraw latency (TWL) measured on day 14 after streptozotocin administration < 80% of the baseline value.The rats were then randomly divided into 3 groups (n =27 each):type 2 DNP group (group DNP); curcumin group (group Cur); solvent control group (group SC).In Cur and SC groups,curcumin 100 mg/kg and corn oil 4 ml/kg were injected intraperitonally,respectively,once a day for 14 consecutive days starting from day 14 after streptozotocin administration.Another 27 normal Sprague-Dawley male rats served as control group (group C) and were fed with normal forage.MWT and TWL were measured before type 2 DNP was induced,after type 2 DNP was induced,and at 3,7 and 14 days after curcumin injection(T1-5).The rats were sacrificed after MWT and TWL were measured at T3-5,and the lumbar segments of the spinal cord and DRG (L4-6) were removed for determination of the expression of MMP-2 and MMP-9 by Western blot.Results Compared with group C,MWT was significantly decreased and TWL was shortened,and MMP-2 and MMP-9 expression in the spinal dorsal horn and DRG was up-regulated in DNP,Cur and SC groups.Compared with DNP group,MWT was significantly increased and TWL was prolonged,and MMP-2 and MMP-9 expression in the spinal dorsal horn and DRG was down-regulated in Cur group,and no significant changes were found in the parameters mentioned above in SC group.Conclusion The mechanism by which curcumin attenuates type 2 DNP may be related to up-regulation of the expression of MMP-2 and MMP-9 in the spinal dorsal horns and DRG of rats.
3.Study on improving accuracy of setup errors of supraclavicular field in radiotherapy for breast cancer by breast bracket and moisture-cured resin cushion
Chuanfeng WU ; Jinchang WU ; Ke GU ; Dongyan WANG ; Yaohua CHU ; Cheng LI ; Danqing SHEN ; Rui HU
Chinese Journal of Radiological Medicine and Protection 2017;37(9):686-689
Objective To explore the effects of improvements on setup error ( SE ) and clinical target ( CTV ) margin of supraclavicular field ( SCF ) by using moisture-cured resin cushion and breast bracket for lower neck fixation in breast cancer patients who underwent post-mastectomy radiotherapy. Methods Totally 13 patients with breast cancer who underwent post-mastectomy radiotherapy were enrolled. All patients were immobilized by breast bracket and moisture-cured resin cushion. Firstly, each patient′s lower neck and head was fixed well by moisture-cured resin cushion, filling the gap between the neck and breast bracket. Secondly,each patient underwent the cone-beam CT ( CBCT) at the first, tenth and twentieth treatment after positioning. Then these CBCT images were registered to the planning CT to determine setup errors in translational and rotational directions, and SCF CTV margins by the systematic and random errors were evaluated. Results The setup errors in x (left-right), y (superior-inferior), z (anterior-posterior) translational directions were (2. 16 ± 1. 25), (1. 50 ± 1. 28), (1. 94 ± 1. 12) mm and (1. 76 ±1. 87)°, (1. 82 ±1. 12)°, (0. 99 ±0. 58)°, respectively in θ (pitch degree),Ф(roll degree),ψ( yaw degree) rotational directions. Non-parametric rank test ( Mann-Whitney U test) was performed with previous data, the differences of the setup error in y, z,θ directions were statistically significant ( Z =4. 152, 3. 415, 2. 053, P<0. 05). The margins from CTV were 4. 07, 4. 03 and 3. 73 mm in x, y and z directions, respectively. Compared with the previous study on SCF, CTV margin required 8, 8 and 6 mm in x, y and z axis directions, the volume of CTV to PTV were decreased by 32. 73% on average. Conclusions Compared with plastic circular pillow alone, moisture-cured resin cushion with breast bracket locating method could reduce setup errors in SCF target region. The margins from CTV to PTV weredecreased to 4. 07, 4. 03 and 3. 73 mm in x, y and z axis directions at least.
4.Changhai fulcrum bending radiographic technique to assess curve flexibility in patients with adolescent idiopathic scoliosis.
Fei WANG ; Jingfeng LI ; Ziqiang CHEN ; Huiqiao WU ; Bo LI ; Xiang HE ; Xianzhao WEI ; Honglei YI ; Chuanfeng WANG ; Yushu BAI ; Xiaodong ZHU ; Ming LI
Chinese Journal of Surgery 2014;52(5):355-360
OBJECTIVETo evaluate the role and value of Changhai fulcrum bending radiograph(CH-FBR) in curve flexibility assessment of adolescent idiopathic scoliosis(AIS) patients.
METHODSThirty-seven AIS patients treated between June 2012 and August 2013 were enrolled, including 31 female and 6 male patients whose age ranged from 10 to 19 years, averaged of 15.0 years. The assessment of radiographs included preoperative standing posterior-anterior radiograph, supine side-bending radiograph, traditional fulcrum bending radiograph, Changhai fulcrum bending radiograph and postoperative standing posterior-anterior radiograph. Postoperatively, radiographs were assessed at one week. The CH-FBR was performed at the lowest height and the optimized height which means the weight on the fulcrum touch the maximum. All measurements of angle were made with use of the Cobb method. The flexibility of the curve as well as the correction rate and fulcrum bending correction index (FBCI) were calculated for all patients. The maximum height of CH-FBR, basic weight and maximum weight were measured for all AIS. Paired t-tests were used to assess differences between preoperative and postoperative curves within group samples. The Pearson correlation coefficients were calculated using bivariate analysis between CH-FBR flexibility rate and correction rate, the maximum height of CH-FBR and maximum weight, the height changes of CH-FBR and weight changes.
RESULTSA total of 46 curves were involved in this study, including 28 thoracic and 18 thoracolumbar/lumbar curves. Preoperatively, the mean Cobb angle of the 46 structural curves was 47° ± 11°. Postoperatively, the mean Cobb angle was 11° ± 5°. Cobb's angle in supine side-bending(t = 7.2, P = 0.001), traditional fulcrum bending (t = 7.1, P = 0.001) and lowest height of Changhai fulcrum bending (t = 6.5, P = 0.001) were significantly different from the postoperative Cobb angle; Cobb's angle in traditional FBR (t = 11.0, P = 0.001) and lowest height of Changhai fulcrum bending (t = 13.6, P = 0.001) were significantly different from the optimized height CH-FBR Cobb angle. There was no significant difference found between traditional FBR Cobb angle and lowest height CH-FBR Cobb angle (t = 2.0, P = 0.051), optimized height CH-FBR Cobb angle and postoperative Cobb angle (t = 0.9, P = 0.36), lowest height CH-FBR Cobb angle and traditional FBR Cobb angle(t = 2.0, P = 0.051). The maximum height of CH-FBR, basic weight and maximum weight were (29.6 ± 1.4)cm,(20 ± 6)kg, and (40 ± 6) kg. Preoperatively, the mean Cobb angle of the 28 structural curves(main thoracic curves) was 46° ± 11°. Postoperatively, the mean Cobb angle was 12° ± 6°. Preoperatively, the mean Cobb angle of the 18 structural curves(thoracolumbar/lumbar curves) was 49° ± 12°. Postoperatively, the mean Cobb angle was 10° ± 5°. The results were same in 28 structural curves, 18 structural curves as well as 46 curves. Correlation analysis of 46 curves indicated that the maximum height of CH-FBR positively correlated with maximum weight (r = 0.69, r(2) = 0.47, P = 0.001), the height changes of CH-FBR positively correlated with weight changes on CH-FBR (r = 0.62, r(2) = 0.38, P = 0.001).
CONCLUSIONSCH-FBR is a more reliable and effective method than traditional FBR and supine side-bending for curve flexibility evaluation in AIS patients. Moreover, compared to the traditional FBR and side-bending radiograph, the flexibility suggested by the optimized height CH-FBR more closely approximates the postoperative result made by pedicle screws fixation and fusion.
Adolescent ; Child ; Female ; Humans ; Male ; Prospective Studies ; Radiography ; Range of Motion, Articular ; Scoliosis ; diagnostic imaging ; surgery ; Young Adult
5.Therapeutic effect comparison of interstitial implantation of I125 seeds and general radiotherapy after surgery of recurrent malignant gliomas
Tongguang ZHANG ; Lu KONG ; Weining YIN ; Chuanfeng LI ; Guoqing WU ; Wei LIU
Chinese Journal of Neuromedicine 2014;13(10):1018-1021
Objective To observe the efficacy and complications of iodine-125 radioactive seeds implantation after surgery of recurrent malignant gliomas.Methods Fifty-eight patients with recurrent gliomas,admitted to our hospital from September 2006 to January 2010,were randomly divided into observation group (n=26) and control group (n=32).All patients accepted tumor subtotal resection.Patients in the observation group were implanted with iodine-125 seeds which were planned by therapy planning system (TPS) depending on the tumor size and position.Patients in the control group were irradiated at 50-60 Gy after the operations.Patients from both groups were followed up for 3 years,and the 1-year and 3-year survival rates,median survival time,complications and quality of life were observed.Results The survival rate of 1-year of observation group and control group was 46.2% and 34.4%,without significant difference (P>0.05),while that of 3-years time was 19.2% and 12.5%,with significant difference (P<0.05).The average survival time of the two groups was (15.6±2.5) months to (9.4±1.3) months,with statistically significant difference (P<0.05).No severe complications (grade four or higher than grade four) were noted; lower rates of dizziness and headache were found in observation group as compared with those in control group (P=0.030,P=0.035).Conclusions The iodine-125 radioactive seeds implantation after surgery of recurrent malignant gliomas not only can improve the survival rate and prolong survival time,but also reduce radiation brain damage to improve the life quality.So it is a safe and effective treatment,and worth of applicattion in clinic.
6. Design of genital organ traction bag and its application in radiotherapy
Yan ZHU ; Huiping SHAN ; Yiqin YANG ; Chuanfeng WU ; Jian GUAN ; Rui HU
Chinese Journal of Practical Nursing 2019;35(33):2634-2637
Objective:
To investigate clinical application of self-designed organ traction bag in male genital immobilization during radiotherapy.
Methods:
The male patients in the Department of Radiation Oncology, Suzhou Municipal Hospital from August 2018 to June 2019 were immobilized by using organ traction bag. Clinical effect was evaluated by subjective and objective ways which were the location relationship between contents and reference field under visual observation and fluoroscopy, and setup errors by CBCT images.
Results:
A total of 11 patients were selected, including 3 seminoma, 2 low rectal carcinoma, 2 prostatic carcinoma, 4 pelvic lymph nodes and bone metastases, with mean age 57.18 years old. Patients received 273 times of treatment and 55 times of CBCT verifications in all. Analysis results that the setup errors of the whole group in upper and lower (Vrt), head and foot (Lng), left and right (Lat) directions are less than 0.5 cm, within acceptable clinical threshold. The contents under visual observation and fluoroscopy were not in reference field and were fixed well.
Conclusions
Organ traction bag provides stable effect on male genital immobilization while taking patients’ privacy and clinical operability into account. It has high clinical application value in radiotherapy involving male genital protection.
7.Neuron stem cell NLRP6 sustains hippocampal neurogenesis to resist stress-induced depression.
Chuanfeng TANG ; Qiaona WANG ; Jingyan SHEN ; Congying WANG ; Hong DING ; Shiyu WEN ; Fan YANG ; Ruiqing JIAO ; Xingxin WU ; Jianmei LI ; Lingdong KONG
Acta Pharmaceutica Sinica B 2023;13(5):2017-2038
Neurogenesis decline in hippocampal dentate gyrus (DG) participates in stress-induced depressive-like behaviors, but the underlying mechanism remains poorly understood. Here, we observed low-expression of NOD-like receptor family pyrin domain containing 6 (NLRP6) in hippocampus of stress-stimulated mice, being consistent with high corticosterone level. NLRP6 was found to be abundantly expressed in neural stem cells (NSCs) of DG. Both Nlrp6 knockout (Nlrp6-/-) and NSC-conditional Nlrp6 knockout (Nlrp6CKO) mice were susceptible to stress, being more likely to develop depressive-like behaviors. Interestingly, NLRP6 was required for NSC proliferation in sustaining hippocampal neurogenesis and reinforcing stress resilience during growing up. Nlrp6 deficiency promoted esophageal cancer-related gene 4 (ECRG4) expression and caused mitochondrial dysfunction. Corticosterone as a stress factor significantly down-regulated NLRP6 expression, damaged mitochondrial function and suppressed cell proliferation in NSCs, which were blocked by Nlrp6 overexpression. ECRG4 knockdown reversed corticosterone-induced NSC mitochondrial function and cell proliferation disorders. Pioglitazone, a well-known clinical drug, up-regulated NLRP6 expression to inhibit ECRG4 expression in its protection against corticosterone-induced NSC mitochondrial dysfunction and proliferation restriction. In conclusion, this study demonstrates that NLRP6 is essential to maintain mitochondrial homeostasis and proliferation in NSCs, and identifies NLRP6 as a promising therapeutic target for hippocampal neurogenesis decline linked to depression.