1.Retrospective analysis of 934 nasopharyngeal carcinoma patients treated with conventional external beam radiotherapy alone.
Tai-xiang LU ; Chong ZHAO ; Shao-xiong WU ; Wei LUO ; Yong CHEN ; Fang-yun XIE ; Ming CHEN ; Xiang-fa ZENG ; Wei-han HU ; Xin-ping CAO ; Yun-fei XIA ; Xiu-fang LIU ; Nian-ji CUI
Chinese Journal of Oncology 2005;27(10):620-622
OBJECTIVETo analyze the clinical outcome of 934 primary nasopharyngeal carcinoma treated with conventional external beam radiotherapy alone.
METHODS34 patients were treated from Jan. 1, 1999 to Dec. 31, 1999. The radiation fields were delineated according to the CT/MRI imaging findings on disease extent. Two lateral opposing isocentric portals with customized blockings were used for the nasopharynx and upper neck. The dose delivered to tumor in the nasopharynx was 68-70 Gy/2 Gy fraction/7 weeks. The doses delivered to the neck was 60-70 Gy/6-7 weeks for patients with positive lymph nodes and 50 Gy/5 weeks for the patients with negative lymph node.
RESULTSThe 1-, 2-, 3- and 4-year overall survival rate (OS) was 89.5%, 81.9%, 78.1% and 75.7%, and metastasis-free survival rate (MFS) was 84.0%, 77.2%, 74.4% and 72.0%, respectively. The 1-, 2-, 3- and 4-year disease-free survival rate (DFS) was 80.8%, 73.1%, 68.5% and 65.1%, and the relapse-free survival rate (RFS) was 95.5%, 92.7%, 90.3% and 87.3%, respectively. The overall failure rate was 30.9% (289/934). At the end of the radiotherapeutic course, the percentage of residual disease was 14.6%. The 4-year loco-regional recurrence and distant metastasis rates after radiotherapy were 7.2% and 9.2% with a median time of 19.3 months and 12.8 months.
CONCLUSIONIt may be helpful to improve radiotherapy curative effect when the target is individually designed through improving irradiation technique according to CT/MRI findings and by shortening the overall course time, enhancing irradiation dose and strictly implementing QA/QC measures.
Adolescent ; Adult ; Aged ; Carcinoma, Squamous Cell ; diagnostic imaging ; radiotherapy ; Female ; Humans ; Magnetic Resonance Imaging ; Male ; Middle Aged ; Nasopharyngeal Neoplasms ; diagnostic imaging ; radiotherapy ; Radiotherapy Dosage ; Retrospective Studies ; Survival Analysis ; Tomography, X-Ray Computed ; Treatment Outcome
2.A rapid identification of authenticity and specifications of Chinese medicine Fritillariae Cirrhosae Bulbus based on E-eye technology.
Rui-Xin LIU ; Xiao-Jia HAO ; Hui-Jie ZHANG ; Lu ZHANG ; Xin-Jing GUI ; Zhao-Zhou LIN ; Chong-Nian LUO ; Liang-Yu TIAN ; Yan-Li WANG ; Wen-Hao FENG ; Jing YAO ; Xue-Lin LI
China Journal of Chinese Materia Medica 2020;45(14):3441-3451
The quality of traditional Chinese medicine tablets is correlated with clinical efficacy and drug safety, and plays a great role in promoting the development of traditional Chinese medicine. However, the existing traditional artificial identification and modern instrument detection in terms of accuracy and timeliness have both advantages and disadvantages. Therefore, how to quickly and accurately identify the quality of traditional Chinese medicine tablets has become a high-profile issue. The purpose of this paper is to explore the feasibility of the application of electronic eye technology in the study of rapid identification of traditional Chinese medicine quality. A total of 80 batches of samples were collected and tested by Fritillariae Cirrhosae Bulbus for traditional empirical identification(M_1) and modern pharmacopeia(M_2). The optical data was collected from electronic eyes, and the chemical metrology was used to establish suitable discrimination models(M_3). Four authenticity and commodity specification models, namely identification analysis(DA), minimum bidirectional support vector machine(LS-SVM), partial minimum two-multiplier analysis(PLS-DA), main component analysis identification analysis(PCA-DA), were established, respectively. The accuracies of the authenticity identification models were 82.5%, 90.0%, 96.2% and 93.8%, while the accuracies of the commodity specification identification models were 89.3%, 96.0%, 90.7% and 97.3%, respectively. The models were well judged, the authenticity identification was based on the final identification model of PLS-DA, and the commodity specification was based on the final identification model of PCA-DA. There was no significant difference between its accuracy and M_1, and the time of determination was much shorter than M_2(P<0.01). Therefore, electronic-eye technology could be used for the rapid identification of the quality of Fritillariae Cirrhosae Bulbus.
Drugs, Chinese Herbal
;
Fritillaria
;
Medicine, Chinese Traditional
;
Plant Roots
;
Technology