1.Research advances in neurobiological mechanism of acupuncture for amblyopia
Chong-Bing MA ; Tian-Tian ZHU ; An-Guo LIU ; Zhao-Xia CAO ; Xing-Ke YAN
Journal of Acupuncture and Tuina Science 2019;17(4):278-283
Amblyopia greatly affects the physical and mental development of children. Acupuncture is effective for amblyopia, though its mechanism remains unclear. This article summarized the mechanism of acupuncture treatment of amblyopia from the perspectives of morphology of neurons in visual cortex, visual electrophysiology, and molecular biology, etc. It was found that acupuncture may treat amblyopia through repairing the morphological and ultrastructural damages of neurons in visual cortex, promoting the electrical activities in visual pathway and visual cortical neurons, and modulating the synthesis and expression levels of factors involved in visual system. Nevertheless, further studies are required to unveil the mechanism of acupuncture treatment of amblyopia.
2.Mechanism of improving effect of losartan on insulin sensitivity of non-insulin-dependent diabetes mellitus rats.
Yong WU ; Jing-Ping OUYANG ; Yun-Feng ZHOU ; Ke WU ; De-Hai ZHAO ; Chong-Yuan WEN
Acta Physiologica Sinica 2004;56(4):539-549
The specific inhibition of angiotensin II action at AT(1) receptors by losartan has been shown to decrease peripheral insulin resistance in type 2 diabetic patients and animal models. We examined the effect of losartan on the expression of insulin receptor substrate 1 (IRS-1), protein kinase B (PKB) and glucose transporter 4 (GLUT4), as well as the phosphorylation status of IRS-1 and the association between IRS-1 and phosphatidylinositol (PI) 3-kinase in skeletal muscle from fat-fed and-streptozotocin (STZ)-treated rats, an animal model of type 2 diabetes mellitus. In addition, the effects of losartan on GLUT4 translocation in muscle cells and on insulin sensitivity were also evaluated. Muscle tissues were isolated from male losartan-treated and untreated normal or non-insulin-dependent diabetes mellitus (NIDDM) rats with a dose of 4 mg/kg per day for 6 weeks. Oral administration of losartan improved insulin sensitivity, which was determined by an oral glucose tolerance test (OGTT). In skeletal muscles, the protein levels of IRS-1, PKB and GLUT4 in NIDDM rats were not significantly different from those of the control rats, and they were not affected by losartan. The levels of IRS-1 tyrosine phosphorylation, PI 3-kinase activity associated with IRS-1 and PKB activation after stimulation with insulin in muscle tissue of NIDDM rats were significantly decreased (P<0.01) compared with those in the control rats, while they were not increased by losartan. Losartan had a major effect on GLUT4 translocation in myocytes, as it significantly increased (P<0.05) the insulin-induced amounts of GLUT4 in plasma membrane (PM) and T-tubules (TT) in myocytes from NIDDM rats. Consistent with these results, the plasma glucose level in losartan-treated NIDDM rats was decreased (P<0.05) compared with that in untreated NIDDM rats. Our results suggest that losartan may exert beneficial effects on insulin resistance by increasing the translocation of GLUT4 in muscle tissue, which is probably associated with a non-PI 3-kinase-dependent mechanism.
Animals
;
Diabetes Mellitus, Experimental
;
blood
;
drug therapy
;
Diabetes Mellitus, Type 2
;
blood
;
drug therapy
;
physiopathology
;
Glucose Transporter Type 4
;
Insulin Receptor Substrate Proteins
;
Insulin Resistance
;
Losartan
;
pharmacology
;
therapeutic use
;
Male
;
Monosaccharide Transport Proteins
;
biosynthesis
;
genetics
;
Muscle Proteins
;
biosynthesis
;
genetics
;
Muscle, Skeletal
;
metabolism
;
Phosphoproteins
;
biosynthesis
;
genetics
;
Protein-Serine-Threonine Kinases
;
biosynthesis
;
genetics
;
Proto-Oncogene Proteins
;
biosynthesis
;
genetics
;
Proto-Oncogene Proteins c-akt
;
Rats
;
Rats, Sprague-Dawley
3.Ultrasound elastography of the thyroid: principles and current status
Ultrasonography 2019;38(2):106-124
Ultrasound (US) elastography has been introduced as a non-invasive technique for evaluating thyroid diseases. This paper presents a detailed description of the technical principles, peculiarities, and limitations of US elastography techniques, including strain elastography and shear-wave elastography. This review was conducted from a clinical perspective, and aimed to assess the usefulness of US elastography for thyroid diseases in specific clinical scenarios. Although its main focus is on thyroid nodules, the applications of US elastography for other thyroid diseases, such as diffuse thyroid diseases and thyroiditis, are also presented. Furthermore, unresolved questions and directions for future research are also discussed.
Elasticity Imaging Techniques
;
Thyroid Diseases
;
Thyroid Gland
;
Thyroid Nodule
;
Thyroiditis
;
Ultrasonography
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Artificial intelligence technology enables ultrasonography in precision diagnosisand treatment of liver diseases
Bo-yang ZHOU ; Yi-lei SHI ; Le-hang GUO ; Li-chao MOU ; Xiao-xiang ZHU ; Chong-ke ZHAO
Chinese Journal of Schistosomiasis Control 2022;34(5):458-464
Liver disease is one of the major problems affecting human health. Ultrasound plays an important role in diagnosis and treatment of diffuse and focal liver diseases. However, conventional ultrasound evaluation is subjective and provides limited information. Artificial intelligence (AI) technology may supplement the disadvantages of conventional ultrasound and has been widely used in the field of ultrasound in liver diseases. To date, remarkable progress has been achieved for the use of AI technology in the diagnosis, assessment of therapeutic efficacy and prognosis prediction of liver diseases. This paper reviews the research progress of ultrasound image-based AI technology in the diagnosis and treatment of diffuse and focal liver diseases.
10.Acanthopanax senticosus Protects Structure and Function of Mesencephalic Mitochondria in A Mouse Model of Parkinson's Disease.
Shu-Min LIU ; Xu-Zhao LI ; Shuai-Nan ZHANG ; Zhi-Ming YANG ; Ke-Xin WANG ; Fang LU ; Chong-Zhi WANG ; Chun-Su YUAN
Chinese journal of integrative medicine 2018;24(11):835-843
OBJECTIVETo investigate the neuro-protective effects of Acanthopanax senticosus Harms (EAS) on mesencephalic mitochondria and the mechanism of action, using a mouse model of Parkinson's disease (PD).
METHODSThe chemical fingerprint analysis of the extract of Acanthopanax senticosus Harms (EAS) was performed using the ultra performance liquid chromatograph and time of flight mass spectrometry. Thirty mice were randomly divided into the control group, the MPTP model group, and the EAS treated group with MPTP (MPTP+EAS group, 10 in each group). The MPTP model group and the MPTP+EAS group received MPTP-HCl (30 mg/kg i.p) once a day for 5 days. The control group received an equal volume of saline (20 mL/kg i.p) once a day for 5 days. Induced by 1-methyl-4-phenyl-1, 2, 3, 6-tetrahydropyridine hydrochloride daily (MPTP-HCl, 30 mg/kg) for 5 days, the PD mice were treated with EAS at 45.5 mg/kg daily for 20 days. The behavioral testing of mice was carried out using the pole-climbing test. The integrity and functions of neurons were examined in mesencephalic mitochondria in a PD mouse model, including nicotinamide adenine dinucleotide dehydrogenase ubiquinone flavoprotein 2 (NDUFV2), mitochondrially encoded nicotinamide adenine dinucleotide dehydrogenase 1 (MT-ND1), succinate dehydrogenase complex subunit A (SDHA), and succinate dehydrogenase cytochrome b560 subunit (SDHC).
RESULTSAfter treatment with EAS, the behavioral changes induced by MPTP were attenuated significantly (P<0.05). EAS protected the mesencephalic mitochondria from swelling and attenuated the decreases in their membrane potential (both P<0.05), which was supported by an ultra-structural level analysis. The changes in reactive oxygen species (ROS), malonic dialdehyde (MDA), oxidative phosphorylation (OXPHOS) system 4 subunits levels and PD-related proteins expressions (parkin, Pink1, DJ-1, α-synuclein, and Lrrk2) reverted to near normal levels (all P<0.05), based on the results of immune-histological and Western blotting observations.
CONCLUSIONSThe neuro-protective effects of EAS are linked to protecting mice against MPTP-induced mitochondrial dysfunction and structural damage. Therefore, EAS is a promising candidate for the prevention or treatment of mitochondrial neurodegenerative disorders, such as PD.