1.The Case Report of a Child with High-Risk Acute Lymphoblastic Leukemia, Treated with Allogenic Peripheral Blood Stem Cell Transplantation.
Jun GOH ; Ji Hyun OH ; Hyun Sang CHO ; Dug Ha KIM ; Chong Young PARK
Journal of the Korean Pediatric Society 2000;43(11):1505-1508
Allogenic peripheral blood stem cell transplantation could be used instead of allogenic bone marrow in treatment of leukemia in children. This 10-year-old female patient with high-risk acute lymphoblastic leukemia received a myeloablative regimen followed by allogenic peripheral blood stem cell transplantation from an HI A-identical sibling donor. Neutrophil recovery to greater than 500/pL occurred at day 11 and platelets recovered to greater than 20,000/pL at day 13. Allogenic peripheral blood stem cell transplantation can be performed safely and may result in a rapid neutrophil and platelet engraftment, without any apparent increased risk of acute graft versus host disease.
Blood Platelets
;
Bone Marrow
;
Child*
;
Female
;
Graft vs Host Disease
;
Humans
;
Leukemia
;
Neutrophils
;
Peripheral Blood Stem Cell Transplantation*
;
Precursor Cell Lymphoblastic Leukemia-Lymphoma*
;
Siblings
;
Tissue Donors
2.Pneumothorax During General Anesthesia - A Case Report-.
Korean Journal of Anesthesiology 1973;6(1):5-7
A case of sudden respiratory distress due to pneumothorax which occurred during simple total hysterectomy under endotracheal nitrous oxide-oxygen-succinylcloline I. V. drip anesthesia has been presented. The pneumothorax was evidenced by chest X-ray, and was believed due to distension and rupture of alveoli associated with positive pressure ventilation. Immediate insertion of an intercostal water-seal drainage and administration of oxgen resulted in uneventful recovery. Literatures have been reviewed, and the importance of pressure-time relationship of ventilation in potential hazards of pneumothorax stressed.
Anesthesia
;
Anesthesia, General*
;
Drainage
;
Hysterectomy
;
Pneumothorax*
;
Positive-Pressure Respiration
;
Rupture
;
Thorax
;
Ventilation
3.Malignant Hyperthermia Following General Anesthesia.
Korean Journal of Anesthesiology 1973;6(1):1-3
A case of malignant hyperthermia manifested by precipitous rise in body temperature, metabolic acidosis and muscular rigidity in a 48 year old farmer with bronchogenic carcinoma after thoracotomy under nitrous oxide-oxygen-halothane-succinylcholine anesthesia has been presented. Despite all strenuous supportive measures, the patient expired 11 (1/2) hours following the surgery. The importance of early recognition and vigorous treatment has been stressed.
Acidosis
;
Anesthesia
;
Anesthesia, General*
;
Body Temperature
;
Carcinoma, Bronchogenic
;
Humans
;
Malignant Hyperthermia*
;
Middle Aged
;
Muscle Rigidity
;
Thoracotomy
4.Recurrent Malignant Phyllodes Tumor with Liposarcoma.
Ji Shin LEE ; Hyung Seok KIM ; Jong Jae JUNG ; Chong Dug CHO
Korean Journal of Pathology 2001;35(6):558-560
Phyllodes tumors are an uncommon mammary tumors composed of benign epithelial elements and cellular, spindle cell stroma. Adipose differentiation is an uncommon stromal alteration in phyllodes tumors. Herein, a case of recurrent phyllodes tumors with liposarcomatous stroma is described. A 30-year-old female presented with a left breast mass. Histologic examination showed a phyllodes tumor with low-grade malignant potential exhibiting a few mitoses and moderate cellularity. It also contained mature adipose tissue as well as a well-differentiated liposarcomatous area. This tumor recurred 43 months later. The recurrent tumor had a higher cellular density and more mitoses than the primary tumor.
Adipose Tissue
;
Adult
;
Animals
;
Breast
;
Female
;
Humans
;
Liposarcoma*
;
Mammary Neoplasms, Animal
;
Mitosis
;
Phyllodes Tumor*
5.A Study on Public Nuisance in Han River and Nackdong River: Part II. Survey on Water Pollution.
Chul Hwan CHA ; Young Soon SHIN ; Soon Young PARK ; Kwang Soo CHO ; Chong Yoo CHOO ; Kyo Sung KIM ; Dug Il CHOI
Korean Journal of Preventive Medicine 1971;4(1):65-76
In view of ever rising water pollution problems of river in the vicinity of large urban communities, the author has made an investigation on the pollution of water sampled from Han River (Seoul area) and Nakdong River (Daegu city area) during the period from july to December, 1970. The water samples were taken twice a month during the study period of 6 months from 7 points (locations) along the main stream of Han River at Seoul city and 5 points of Nakdong River at Daegu city. The samples ware measured and analyzed in accordance with the recognized methods in the "Standard Methods or Examination of Water and waste" by American Public Health Association. The obtained results are as follows: I.Han River. 1. Average turbidity was 5.1 units ranging from 1 to 10 units and the turbidity of down stream was higher than that of the upper stream. 2. pH value showed slight alkalinity (mean ; 7.2) except Yunchang-Dong (6.9). 3. The mean value of Dissolved Oxygen contents (D.O) was 7.2 ppm (range of 3.4-10.5ppm). D.O of the upper stream (8.2 ppm. at Walker Hill boating place, 8.0 ppm. at the Gwangzang Bridge and Ddookdo) was higher than that of he downstream (5.6ppm. at Yunchang-Dong. 6.4ppm. at the 2nd Han River Bridge), and D.O in the winter season was higher than that in the summer season, respectively. 4. The mean value of the Biochemical Oxygen Demand (B.O.D.) was 28.3 ppm. (range of 6.2-64.8ppm). The mean value of B.O.D. was 48.7 ppm. at Yunchang-Dong. 42.3ppm. at the 2nd Han River Bridge, 34.0 ppm. at the 1st Han River bridge, 28.5 ppm. at the 3rd Han River Bridge, 19.2 ppm. at Dookdo, 13.2 ppm. at the Gwangzang Bridge, and 10.2 ppm. at the Walker Hill boating place in order of value. B.O.D. in July and August (35.6 and 34.5 ppm.) were the highest and that in November and December (18.6 and 21.2 ppm.) were the lowest. 5. Suspended Solids (SS) were from 15.0 to 667.0 ppm. with the mean of 222.1 ppm "Suspended Solids" of the water samples at Yunchang-Dong and the 2nd Han River Bridge were found to be 378.1 ppm. and 283.9 ppm. respectively which were higher than at the Gwangzang Bridge (134.1ppm.) and at Walker Hill boating place (79.3ppm). 6. Coliform colonies counting of the water samples ranged from 0-2, 500x10/100ml. with the mean value of 205.6x10/100ml. The most contaminated water sample by coliform were from the point of the 2nd Han River Bridge with 640.8x10/100ml while the lowest ones were from Walker Hill boating place with 17.2x10/100ml. There was also a seasonal variation in coliform contamination that is the higher in summer and the lower in winter. II. Nakdong River. 1. The mean value of turbidity was 2.3 units with range of 0 to 9.0 units. The highest point was at Geumho River (7.2 units). and the lowest point was at Gangzung and Moonsan (0.45 and 0.41 units). 2. The mean value of pH was 7.5 (range of 7.1-8.5) and highest point was Geunho River with 8.5. 3. The mean value of D.O was 8.1ppm. (range of 3.4-11.2 ppm.). D.O. of the upper stream showed higher value than that of the down stream, and the winter season than the summer season. 4. B.O.D. ranged from 2.6 to 57.0 ppm. (mean; 20.4 ppm.). The water sample at Geumho River showed the highest value (41.5ppm) while at Moonsan and Gangzung showed the lowest (4.6 and 4.7 ppm.). 5. The mean value of suspended solids was 48.7 ppm. (range of 4.0-182.0 ppm.). The highest month was July (63.7 ppm.) and August (62.1 ppm.) and the lowest month was October (37.0 ppm.) and December (24.4 ppm.). 6. The mean value of the coliform colonies was 22.7x10/100ml. (range of 0-243x10/100ml.). The highest number of the colonies was found in the sample water at the Whawon recreation area (50.5x10/100ml.) followed by the Geumho River (33.9x10/100ml;), the Goryung Bridge (28.3x10/100ml.), Gangzung(0.7x10/100ml), and Moonsan (0.6x10/100ml.).
American Public Health Association
;
Daegu
;
Hydrogen-Ion Concentration
;
Oxygen
;
Recreation
;
Rivers*
;
Seasons
;
Seoul
;
Ships
;
Water Pollution*
;
Water*
6.A Study on Public Nuisance in Seoul, Pusan and Daegu Cities: Part 1. Survey on Air Pollution and Noise Level.
Chul Hwan CHA ; Young Soo SHIN ; Young Il LEE ; Kwang Soo CHO ; Chong Yoo CHOO ; Kyo Sung KIM ; Dug Il CHOI
Korean Journal of Preventive Medicine 1971;4(1):41-64
During the period from July 1st to the end of November 1970, a survey on air pollution and noise level was made in Seoul, Pusan and Taegu, the three largest cities in Korea. Each city was divided into 4-6 areas : the industrial area, the semi-industrial area, the commercial area, the residential area, the park area and the downtown area. Thirty eight sites were selected from each area. A. Method of Measurement : Dustfall was measured by the Deposit Gauge Method, sulfur oxides by PbO2 cylinder method, suspended particles by the Digital Dust Indicator, Sulfur dioxide (SO2) and Carbon Monoxide (CO) by the MSA & Kitakawa Detector and the noise levels by Rion Sound Survey meter. B. Results: 1. The mean value of dustfall in 3 cities was 30.42 ton/km2/month, ranging from 8.69 to 95.44. 2. The mean values of dustfall by city were 33.17 ton/km2/month in Seoul, 32.11 in Pusan and 25.97 in Taegu. 3. The mean values of dustfall showed a trend of decreasing order of semi-industrial area, downtown area, industrial area, commercial area, residential area, and park area. 4. The mean value of dustfall in Seoul by area were 52.32 ton/km2/month in downtown, 50.54 in semi-industrial area, 40.37 in industrial area, 24,19 in commercial area, 16.25 in park area and 15.39 in residential area in order of concentration. 5. The mean values of dustfall in Pusan by area were 48.27 ton/km2/month in semi-industrial area, 36.68 in industrial area 25.31 in commercial area, and 18.19 in residential area. 6. The mean values of dustfall in Taegu by area were 36.46 ton/km2/month in downtown area, 33.52 in industrial area, 20.37 in commercial area and 13.55 in residential area. 7. The mean values of sulfur oxides in 3 cities were 1.52mg SO3/day/100cm2 PbO2, ranging from 0.32 to 4.72. 8. The mean values of sulfur oxides by city were 1.89mg SO3/day/100cm2 PbO2, in Pusan, 1.64 in Seoul and 1.21 in Taegu. 9. The mean values of sulfur oxides by area in 3 cities were 2.16mg SO3/day/100cm2 PbO2 in industrial area, 1.69 in semi-industrial area, 1.50 in commercial area, 1.48 in downtown area, 1.32 in residential area and 0.94 in the park area, respectively. 10. The monthly mean values of sulfur oxides contents showed a steady increase from July reaching a park in November. 11. The mean values of suspended particles was 2.89mg/m3, ranging from 1.15 to 5.27. 12. The mean values of suspended particles by sity were 3.14mg/m3 in Seoul, 2.79 in Taegu and 2.25 in Pusan. 13. The mean values of noise level in 3 cities was 71.3 phon, ranging from 49 to 99 phon. 14. The mean values of noise level by city were 73 phon in Seoul, 72 in Pusan and 69 in Taegu in that order. 15. The mean values of noise level by area in 3 cities showed a decrease in the order of the downtown area, commercial area, industrial area and semi-industrial area, park area and residental area. 16. The mean values of noise level by area in 3 cities indicated that the highest level was detected in the downtown area in Seoul and Taegu and in the industrial area in Pusan. 17. The daily average concentration o sulfur dioxides (SO2) in 3 cities was 0.081 ppm, ranging from 0.004 to 0.196. 18. The daily average concentration of sulfur dioxides by city were 0.092 ppm in Seoul, 0.089 in Pusan and 0.062 in Taegu in that order. 19. the weekly average concentration of carbon monoxides (CO) was 27.59 ppm. 20. The daily average concentration of carbon monoxides by city were 33.37 ppm. in Seoul, 25.76 in Pusan and 23.65 in Taegu in that order. 21. The concentration of SO2 and CO reaches a peak from 6 p.m. to 8 p.m. 22. About 3 times probably the daily average concentration of CO could be detected in the downtown area probably due to heavy traffic emission in comparison with that in the industrial area. 23. As for daily variation of the concentration of SO2 and CO it was found that the concentration maintains relatively higher value during weekdays in the industrial area and on the first part of the week in the downtown area.
Air Pollution*
;
Busan*
;
Carbon
;
Carbon Monoxide
;
Daegu*
;
Dust
;
Korea
;
Noise*
;
Seoul*
;
Sulfur
;
Sulfur Dioxide
;
Sulfur Oxides