1.Simultaneous determination of three organic fluorides in workplace air by portable gas chromatography-mass spectrometer.
Feng ZHANG ; Chaoyi XIN ; Baoli ZHU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2015;33(6):476-478
OBJECTIVETo establish a method for rapid determination of organic fluorides in the air of a fluorine chemical plant using portable gas chromatography-mass spectrometer (GC-MS).
METHODSStandard samples of monochlorodifluoromethane, tetrafluoroethylene, and hexafluoropropylene of different concentrations were prepared by static volumetric method with high-purity nitrogen as the diluent gas. The samples were injected into the GC-MS by a hand-held probe. Retention time and characteristic ion were used for qualitative analysis, and the area of selected ion peak was used for quantitative analysis. The standard curves were then created for quantitative determination of the three organic fluorides.
RESULTSThe linear ranges for monochlorodifluoromethane, tetrafluoroethylene, and hexafluoropropylene by the method were 0.39-7.72, 0.45-8.84, and 0.61-12.20 mg/m3, respectively, the average recovery rates for the three concentrations were 102.8%, 96.0%, and 106.5%, respectively, and the average deviations were 2.1%, 5.1%, and 2.4%, respectively.
CONCLUSIONThe portable GC-MS can be used for the simultaneous qualitative and quantitative analysis of monochlorodifluoromethane, tetrafluoroethylene, and hexafluoropropylene in the workplace air, and the method is simple, fast, and accurate.
Air Pollutants, Occupational ; analysis ; Chlorofluorocarbons, Methane ; analysis ; Fluorides ; analysis ; Fluorocarbons ; analysis ; Gas Chromatography-Mass Spectrometry ; Workplace
3.The Effect of Spacer on the Bronchodilator Response in the First Medical Examination of Old Age.
Yang Deok LEE ; Sung Kyun SIN ; Yong Seon CHO ; Min Soo HAN
Journal of the Korean Geriatrics Society 2004;8(4):228-232
BACKGROUNDS: When measuring lung function and response to bronchodilator, MDI(metered-dose inhaler) is commonly used but unfamiliarity of its use and cold sensation by the puffed gas decrease reliability of the result. Spacer can reduce the cold freon effect and undesired oropharyngeal deposition caused by the rapid evaporation of the propellant and there are many studies which showed more effectiveness of spacer on the treatment of children with asthma but no study whether it is effective on the bronchodilator response test in the first medical examination of old age. Therefore, we tested whether the use of spacer can reduce the cold freon effect and improve the bronchodilator response in the first medical examination of old age. METHODS: Two hundred of elderly patients( 65years) who had never used MDI were measured the bronchodilator response. Subjects were randomised to either spacer-user or spacer-nonuser. Twenty minutes after 400 g fenoterol was administered, FEV1 (forced expiratory volume in one second) was measured. Bronchoconstriction was defined as a decrease in FEV1 by 10% or greater after bronchodilator inhalation. We further devided each group into normal or obstructive group, obstructive group was defined as FEV1<80% of predicted and FEV1/FVC<70%. RESULTS: In normal group, spacer-user(n=83) showed greater bronchodilator response than spacer-nonuser(n=66), 6.43% vs 3.81% respectively(p<0.05) and two case of bronchoconstriction occured only in spacer-nonuser. In obstructive group, there is no significant difference in bronchodilator response between spacer-user(n=18) and spacer-nonuser(n=33), 12.32% vs 11.16% respectively(p>0.05) but brochoconstriction(n=1) occured only in spacer-nonuser. CONCLUSION: Spacer improved bronchodilator response and prevented bronchoconstriction, in the first medical examination of old age.
Aged
;
Asthma
;
Bronchoconstriction
;
Child
;
Chlorofluorocarbons
;
Fenoterol
;
Humans
;
Inhalation
;
Lung
;
Sensation
4.Metered dose inhaler(MDI)-induced bronchocostriction in asthmatic patients: the effects of the incert ingredients and propellants.
Jun Woo BAHN ; Ho Joo YOON ; Jee Woong SON ; Sang Heon CHO ; Dong Chull CHOI ; Kyung Up MIN ; Yon Young KIM
Journal of Asthma, Allergy and Clinical Immunology 1998;18(1):78-83
BACKGROUND: Bronchoconstriction associated with aerosolized agents delivered by a metered dose inhaler (MDI) is relatively uncommon, but has been of particular interest. MATERIAL AND METHOD: In this study, we investigated to what extent the inert ingredients and propellants (freons) influence pulmonary function in 25 asthmatic patients. Forced expiratory volume in one second(FEV,) was measured by spirometry, Autospira HI 498(Chest, Japan) before and 1, 3, 5 and 10 minutes after the inhalation of saline control and MDI-placebo containing freons and inert ingredients. RESULT: Twenty four % (6/25) of asthmatics experienced a decrease in FEV20 by 10% or greater when compared to saline control. Number of positive cases in steroid dependent asthmatics is significantly higher compared to non-steroid dependent asthmatics. (p<0.05) Bronchoconstriction associated with the use of MDI-placebo appeared within 3 to 5 minutes and resolved spontaneouly at 10 minutes after the inhalation. CONCLUSION: The bronchoconstrictive response induced by MDI might be caused by the pro-pellants and/or the other inert ingredients contained in MDIs.
Bronchoconstriction
;
Chlorofluorocarbons
;
Forced Expiratory Volume
;
Humans
;
Inhalation
;
Metered Dose Inhalers
;
Spirometry
5.Asphyxia Due to Oxygen Deficiency: The Report of Two Autopsy Cases.
Seok Hoon JEON ; Hyo Jeong KANG ; Jang Hee KIM ; Sang Yong LEE ; Chan Seong PARK ; Jin Pyo KIM ; Joong Seok SEO
Korean Journal of Legal Medicine 2004;28(2):47-51
Two autopsy cases of asphyxia due to oxygen deficiency are reported. The first case is that a 38-year-old man died in a storehouse. Many pears were stored in a storehouse and the its atmosphere was strictly controlled. The second case is that a 42-year-old man died in the boiler room of a fishing ship. Much amount of Freon gas escaped due to a defect of the refrigerator in the boiler room. The victim entered the boiler room because he repaired the refrigerator. But, the victim died when he entered the boiler room immediately. In this article, the autopsy findings and the contents of the investigation of scene of two cases are described.
Adult
;
Anoxia*
;
Asphyxia*
;
Atmosphere
;
Autopsy*
;
Chlorofluorocarbons
;
Humans
;
Oxygen*
;
Pyrus
;
Ships
;