1.Enhancing quality management of regional palliative care services: a case study of Shanghai palliative care service management center
Chihang LI ; Yumiao WU ; Bao LIU ; Shuijing LI ; Ying WU ; Xiaolin WANG
Chinese Journal of General Practitioners 2024;23(2):171-175
Palliative care, as an emerging discipline, is rapidly advancing in China. However, progress in quality management has been relatively slow, hindering the homogeneity of palliative care services in a certain degree. This article takes the Shanghai Palliative Care Service Management Center as an example, outlines its practical model and achievements in the field of quality management since its establishment, and further analyzes the existing problems based on the city-wide palliative care service quality evaluation results. The article summarizes relevant experiences and offers corresponding insights, enriching research cases and practical support in the quality management of palliative care, which may have practical application value for enhancing the homogeneity of palliative care services in the region.
2.Transverse sinus blood flow characteristics of pulsatile tinnitus with dehiscent sigmoid plate based on 4D flow MRI
Chihang DAI ; Heyu DING ; Han LYU ; Xiaoyu QIU ; Xiaoshuai LI ; Rong ZENG ; Guopeng WANG ; Zhenghan YANG ; Shusheng GONG ; Zhenchang WANG ; Pengfei ZHAO
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2024;59(9):897-901
Objective:To investigate the hemodynamic characteristics of transverse sinus with sigmoid sinus wall dehiscence (SSWD) of pulsatile tinnitus (PT) based on 4D flow MRI.Methods:Retrospective analysis was performed on all patients admitted to Beijing Friendship Hospital, Capital Medical University from January 2019 to January 2021 for dehiscent sigmoid plate pulsatile tinnitus. A total of 26 patients (sides) who met the criteria and underwent 4D flow MRI were included. A total of 26 subjects (46 sides), matched 1∶1 according to gender and age, were included in the normal healthy control group. Nonparametric rank sum test, Student′s t test, and ANOVA were performed by SPSS 19.0 software. Binary Logistic regression was applied to the data with statistical significance. Results:There were more patients with dominant drainage on the affected side in PT group than in control group (73.1% vs. 42.3%). The incidence of transverse with a focal intraluminal filling defect and tapered stenosis was higher than that in control group (21.7% vs. 69.2%; 17.4% vs. 42.3%). Average through-plane velocity and maximum through-plane velocity in PT group were higher than those in control group [(33.75±13.88) cm/s vs. (15.84±7.21) cm/s; (93.19±33.55) cm/s vs. (40.40±14.40) cm/s]. The middle part and proximal end of Flow avg (ml/s) in PT group were larger than those in control group [4.69 (2.87; 5.62) ml/s vs. 2.76 (1.67; 4.99) ml/s; 3.41 (2.16; 5.47) ml/s vs. 2.67 (1.68; 4.41) ml/s]. In control group, the velocity of transverse sinus changed relatively gently, while in PT group, the velocity of proximal sinus increased significantly. Binary Logistic regression showed that SSWD PT was independently correlated with proximal maximum flow velocity [ OR=1.086(1.029-1.146), P=0.003]. Conclusion:4D flow MRI showed that the dominant drainage and higher velocity at the proximal end of the transverse sinus might be an important hemodynamic characteristics of dehiscent sigmoid plate pulsatile tinnitus.