1.Study on population pharmacokinetics of levetiracetam in post-stroke epilepsy patients
Chenxi LIU ; Yin WU ; Caiyun JIA ; Sai CUI ; Huizhen WU ; Suxing WANG
China Pharmacy 2025;36(5):594-599
OBJECTIVE To establish population pharmacokinetic model of levetiracetam (Lev) for Chinese patients with post- stroke epilepsy (PSE), and provide reference for formulating individualized dosing regimens for Lev therapy in this specific population. METHODS Blood concentration data and clinical diagnosis and treatment information of PSE patients meeting the inclusion criteria were retrospectively collected and divided into model group and validation group at an 8∶2 ratio using a random number method. Based on the model group data, a population pharmacokinetic model was developed using nonlinear mixed-effects modeling. Internal evaluation was performed through goodness-of-fit tests and bootstrap analysis, while external validation was conducted using the validation group data. RESULTS A total of 75 blood concentration measurements from 70 PSE patients were collected, with 60 measurements from 55 patients used for model development and 15 measurements from 15 patients reserved for external validation. The final model estimated a population typical value of clearance at 2.98 L/h. Estimated glomerular filtration rate, daily dose, and homocysteine level significantly influenced clearance of Lev (P<0.01). The model demonstrated satisfactory predictive performance, as evidenced by goodness-of-fit tests, bootstrap analysis, and external validation results. CONCLUSIONS Daily dose, estimated glomerular filtration rate, and homocysteine level are identified as significant covariates influencing Lev clearance in Chinese PSE patients. When making clinical decisions, comprehensive consideration should be given to the patient’s treatment response, physiological and pathological conditions, and the occurrence of adverse reactions, etc. The dosage of Lev should be adjusted based on the results of population pharmacokinetic model.
2.Effect of Compatibility of Effective Monomer Components of Fujin Shengjisan on Angiogenesis of HUVEC Based on Uniform Design
Xianying LU ; Jing GAO ; Dingxi BAI ; Chaoming HOU ; Wenting JI ; Huan CHEN ; Chenxi WU
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(8):9-20
ObjectiveTo determine the optimal combination of the effective monomer components "quercetin-kaempferol-abietic acid-boswellic acid" in Fujin Shengjisan for promoting diabetic ulcer (DU) wound healing through uniform design, thereby achieving the modern application of the ancient formula. MethodsFollowing the principle of "uniform design-pharmacodynamic experiment-mathematical modeling and model verification", the U14(145) uniform design table was adopted.The four monomer components of Chinese medicine were considered as the independent variables, and the proliferation rate of human umbilical vein endothelial cells (HUVECs) induced by glucose was used as the pharmacodynamic indicator. A mathematical model was constructed using DPS software to correlate the effective monomer components with the pharmacodynamic indicator. The results of uniform design were verified through CCK-8 assay, cell scratch healing, tube formation, Western blot, and Real-time PCR. ResultsAmong the 14 compatibility groups, compared with the high-glucose model group, compound compatibility group 6 showed the strongest proliferation effect and statistical significance (P<0.05). Four quadratic polynomial regression equations (Y1-Y4) were obtained through DPS modeling. Considering the model's fit, stability, and practical application, equations Y1-Y3 were selected for the follow-up verification. To ensure experiment reproducibility, group 6 was used for validation. Group 6 and equations Y1-Y3 were renamed as compound prescription ① to compound prescription④, respectively, to represent the modern application of the ancient FJSJ Powder through compatibility of monomer components. Verification experiments showed that in the CCK-8, scratch healing, and tube formation assays, the cell viability, wound healing rate, and tube formation number of HUVECs stimulated with 50 mmol·L-1 glucose were significantly reduced compared with the blank group. Moreover, the expression levels of angiogenesis-related cytokines, vascular endothelial growth factor (VEGF) and fibroblast growth factor 2 (FGF2), and CD31 secretion were significantly down-regulated. However, after intervention with compound prescriptions ① to ④, compound prescriptions ① and ③ significantly improved the biological functions of HUVECs induced by 50 mmol·L-1 glucose. Further analysis of the regression coefficients of compound prescriptions ① and ③, and the relative dose ratios of each monomer component, indicated that abietic acid, quercetin, and boswellic acid promoted angiogenesis of HUVECs in the high glucose environment, with a major effect (positive partial correlation coefficients, all > 0.9). Abietic acid and boswellic acid, as well as kaempferol and boswellic acid, promoted angiogenesis in HUVECs through interaction (positive partial correlation coefficients). ConclusionCompound prescriptions ① and ③ are the optimal combinations. They can reverse the inhibitory effects of high glucose, stimulate the proliferation, migration, and tube formation abilities of HUVECs in a high glucose environment, and promote the expression of vascular endothelial growth factorA(VEGFA), FGF2, and CD31, thereby promoting angiogenesis and facilitating DU wound healing. This finding not only confirms the good reproducibility and feasibility of compound prescriptions ① and ③ but also provides new insights and methods for the rational construction of mathematical models to further study the compatibility theory of Chinese medicine.
3.Efficacy comparison of different intraocular lens fixation in the treatment of aphakic patients lacking capsule support
Hua WU ; Lei YAO ; Yayuan YANG ; Chenxi YANG ; Lixin CHEN
International Eye Science 2025;25(8):1313-1316
AIM: To compare the efficacy of different intraocular lens(IOL)fixation in aphakic patients lacking capsule support.METHODS:Retrospective study. Totally 120 cases(120 eyes)of aphakia patients who lacked capsule support admitted to our hospital from June 2019 to June 2024 were selected as the study subjects and randomly assigned into group A and group B, with 60 cases in each group. Group A underwent subcapsular IOL deep scleral fixation, while group B underwent IOL suture suspension fixation in the ciliary groove. The surgery time, uncorrected visual acuity(UCVA), best corrected visual acuity(BCVA), intraocular pressure(IOP), corneal endothelial cell density(CECD), corneal endothelial cell loss rate, and postoperative complications were compared between the two groups before and at 1, 3, 6 mo after surgery.RESULTS:The operation time of the group A was lower than that of the group B(24.69±2.69 vs. 32.75±3.75 min, t=11.937, P<0.05). The UCVA and BCVA in both groups were better than those before operation, and the group A was better than the group B(all P<0.05). The loss rates of corneal endothelial cells in the group A were lower than those in the group B at 1, 3 and 6 mo after surgery, the IOP in the group A was lower than that in the group B at 1 mo after surgery, and the CECD in the group A was higher than the group B(all P<0.05). The 3 eyes(5.0%)of the postoperative IOL ectopic in the group A were less than 11 eyes in the group B(18.3%, P=0.023).CONCLUSION:Subcapsular IOL deep scleral fixation has prominent curative effects on aphakic patients who lack capsule support. It helps improve vision, with less operation time, and fewer postoperative complications.
4.Infrared thermography-assisted design and harvesting of ultrathin anterolateral thigh perforator flaps.
Chenxi ZHANG ; Jiadong PAN ; Shanqing YIN ; Guoqing SHAO ; Xianting ZHOU ; Gaoxiang YU ; Luzhe WU ; Xin WANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(9):1143-1148
OBJECTIVE:
To explore the application value of infrared thermography in the design and harvesting of ultrathin anterolateral thigh perforator flaps.
METHODS:
Between June 2024 and December 2024, 9 cases of ultrathin anterolateral thigh perforator flaps were designed and harvested with the assistance of infrared thermography. There were 7 males and 2 females, aged 21-61 years (mean, 39.8 years). The body mass index ranged from 19.49 to 26.45 kg/m² (mean, 23.85 kg/m²). Causes of injury included 5 cases of traffic accident injuries and 4 cases of machine crush injuries. There were 3 cases of leg wounds, 2 cases of foot wounds, and 4 cases of hand wounds. After debridement, the size of wound ranged from 7 cm×4 cm to 13 cm×11 cm. The time from admission to flap repair surgery was 5-12 days (mean, 7 days). Preoperatively, perforator localization was performed using a traditional Doppler flow detector and infrared thermography, respectively. The results were compared with the actual intraoperative locations; a discrepancy ≤10 mm was considered as consistent localization (positive), and the positive predictive value was calculated. All 9 cases were repaired with ultrathin anterolateral thigh perforator flaps designed and harvested based on thermographic images. The size of flap ranged from 8 cm×5 cm to 14 cm×8 cm, with a thickness of 3-6 mm (mean, 5.2 mm). One donor site was repaired with a full-thickness skin graft, and the others were sutured directly. Postoperatively, anti-inflammatory, anticoagulant, and anti-vascular spasm treatments were administered, and follow-up was conducted.
RESULTS:
The Doppler flow detector identified 22 perforating vessels within the set range, among which 16 were confirmed as superficial fascia layer perforators intraoperatively, with a positive predictive value of 72.7%. The infrared thermograph detected 23 superficial fascia layer perforating vessels, and 21 were verified intraoperatively, with a positive predictive value of 91.3%. There was no significant difference between the two methods [OR (95%CI)=3.93 (0.70, 22.15), P=0.100]. The perforator localization time of the infrared thermograph was (5.1±1.3) minutes, which was significantly shorter than that of the Doppler flow detector [(10.1±2.6) minutes; MD (95%CI)=-5.00 (-7.08, -2.91), P<0.001]. Postoperatively, 1 case of distal flap necrosis healed after dressing change; all other flaps survived successfully. The skin grafts at donor site survived, and all incisions healed by first intention. All patients were followed up 3-6 months (mean, 4.7 months). No pain or other discomfort occurred at the donor or recipient sites. All patients with foot wounds could walk with shoes, and no secondary flap revision was required. Flaps in 3 hand wound cases, 2 foot wound cases, and 3 leg wound cases recovered light touch and pressure sensation, but not pain or temperature sensation; the remaining 2 cases had no sensory recovery.
CONCLUSION
Preoperative localization using infrared thermography for repairing ultrathin anterolateral thigh perforator flaps can help evaluate the blood supply status of perforators, reduce complications, and improve surgical safety and flap survival rate.
Humans
;
Perforator Flap/blood supply*
;
Adult
;
Male
;
Thermography/methods*
;
Female
;
Thigh/blood supply*
;
Middle Aged
;
Plastic Surgery Procedures/methods*
;
Tissue and Organ Harvesting/methods*
;
Infrared Rays
;
Skin Transplantation/methods*
;
Soft Tissue Injuries/surgery*
;
Young Adult
5.Metabolic reprogramming nanomedicine potentiates colon cancer sonodynamic immunotherapy by inhibiting the CD39/CD73/ADO pathway.
Yuanyuan ZHANG ; Weiwei JIN ; Zhichao DENG ; Bowen GAO ; Yuanyuan ZHU ; Junlong FU ; Chenxi XU ; Wenlong WANG ; Ting BAI ; Lianying JIAO ; Hao WU ; Mingxin ZHANG ; Mingzhen ZHANG
Acta Pharmaceutica Sinica B 2025;15(5):2655-2672
Sonodynamic therapy (SDT) can potentially induce immunogenic cell death in tumor cells, leading to the release of ATP, and facilitating the initiation of an immune response. Nevertheless, the enzymes CD39 and CD73 can swiftly convert ATP into immunosuppressive adenosine (ADO), resulting in an immunosuppressive tumor microenvironment (TME). This study introduced a nanomedicine (QD/POM1@NP@M) engineered to reprogram TME by modulating the CD39/CD73/ADO pathway. The nanomedicine encapsulated sonosensitizers silver sulfide quantum dots, and the CD39 inhibitor POM1, while also incorporating homologous tumor cell membranes to enhance targeting capabilities. This integrated approach, on the one hand, stimulates the release of ATP via SDT, thereby initiating the immune response. In addition, it reduced the accumulation of ADO by inhibiting CD39 activity, which ameliorated the immunosuppressive TME. Upon administration, the nanomedicine demonstrated substantial anti-tumor efficacy by facilitating the infiltration of anti-tumor immune cells, while reducing the immunosuppressive cells. This modulation effectively transformed the TME from an immunologically "cold" state to a "hot" state. Furthermore, combined with the checkpoint inhibitor α-PDL1, the nanomedicine augmented systemic anti-tumor immunity and promoted the establishment of long-term immune memory. This study provides an innovative strategy for combining non-invasive SDT and ATP-driven immunotherapy, offering new ideas for future cancer treatment.
6.Erratum: Author correction to "SHP2 inhibition triggers anti-tumor immunity and synergizes with PD-1 blockade" Acta Pharm Sin B 9 (2019) 304-315.
Mingxia ZHAO ; Wenjie GUO ; Yuanyuan WU ; Chenxi YANG ; Liang ZHONG ; Guoliang DENG ; Yuyu ZHU ; Wen LIU ; Yanhong GU ; Yin LU ; Lingdong KONG ; Xiangbao MENG ; Qiang XU ; Yang SUN
Acta Pharmaceutica Sinica B 2025;15(5):2810-2812
[This corrects the article DOI: 10.1016/j.apsb.2018.08.009.].
7.Chromatin landscape alteration uncovers multiple transcriptional circuits during memory CD8+ T-cell differentiation.
Qiao LIU ; Wei DONG ; Rong LIU ; Luming XU ; Ling RAN ; Ziying XIE ; Shun LEI ; Xingxing SU ; Zhengliang YUE ; Dan XIONG ; Lisha WANG ; Shuqiong WEN ; Yan ZHANG ; Jianjun HU ; Chenxi QIN ; Yongchang CHEN ; Bo ZHU ; Xiangyu CHEN ; Xia WU ; Lifan XU ; Qizhao HUANG ; Yingjiao CAO ; Lilin YE ; Zhonghui TANG
Protein & Cell 2025;16(7):575-601
Extensive epigenetic reprogramming involves in memory CD8+ T-cell differentiation. The elaborate epigenetic rewiring underlying the heterogeneous functional states of CD8+ T cells remains hidden. Here, we profile single-cell chromatin accessibility and map enhancer-promoter interactomes to characterize the differentiation trajectory of memory CD8+ T cells. We reveal that under distinct epigenetic regulations, the early activated CD8+ T cells divergently originated for short-lived effector and memory precursor effector cells. We also uncover a defined epigenetic rewiring leading to the conversion from effector memory to central memory cells during memory formation. Additionally, we illustrate chromatin regulatory mechanisms underlying long-lasting versus transient transcription regulation during memory differentiation. Finally, we confirm the essential roles of Sox4 and Nrf2 in developing memory precursor effector and effector memory cells, respectively, and validate cell state-specific enhancers in regulating Il7r using CRISPR-Cas9. Our data pave the way for understanding the mechanism underlying epigenetic memory formation in CD8+ T-cell differentiation.
CD8-Positive T-Lymphocytes/metabolism*
;
Cell Differentiation
;
Chromatin/immunology*
;
Animals
;
Mice
;
Immunologic Memory
;
Epigenesis, Genetic
;
SOXC Transcription Factors/immunology*
;
NF-E2-Related Factor 2/immunology*
;
Mice, Inbred C57BL
;
Gene Regulatory Networks
;
Enhancer Elements, Genetic
8.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
9.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
10.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.

Result Analysis
Print
Save
E-mail