1.Effects and safety of PercuSurge distal protection device in coronary intervention in acute myocardial infarction
Xuyang FENG ; Chengxiang LI ; Yan GAO
Chinese Journal of Interventional Cardiology 1996;0(01):-
Objective To evaluate the effects and safety of PercuSurge distal protection device(DPD) in coronary intervention in patients with acute myocardial infarction. Methods From December 2003 to December 2005, 174 acute myocardial infarction patients who received primary coronary intervention were included into this study. Patients were divided into the DPD group (n=78) and the control group (n=96) according to whether Percusurge DPD was attempted during emergency PCI. The basic clinical characteristics, angiographic results, and follow up data before discharge were compared. TIMI flow grades and myocardial blush grades were performed in all cases after emergency PCI. Results Success application was achieved in 72 out of 78 patients with PercuSurge DPD with varies extent of material collected from the basket. There was no significant difference between the two groups in basic clinical characteristics and angiogram before PCI. Post-PCI TIMI flow grades (94.9% vs 79.2%) and myocardial blush grades (2.65?0.68 vs 2.22?0.94) were significantly higher in the DPD guoup than in the control group(P
2.Analysis of frequency-domain and window effect for cellular inner and outer membranes subjected to pulsatile electric field.
Chenguo YAO ; Xin CHEN ; Chengxiang LI ; Yan MI ; Caixin SUN
Journal of Biomedical Engineering 2011;28(1):12-17
Based on multi-layer dielectric model of spherical biological cell, a simulating method of frequency characteristics of inner and outer membranes is presented in this paper. Frequency-domain analysis showed that inner and outer membranes subjected to pulsed electric field exhibit band-pass and low-pass filter characteristics, respectively. A calculating method of the transmembrane potential of inner and outer membranes induced by time-varying electric field was introduced, and the window effect between electric field and transmembrane potential was also analyzed. When the duration is reduced from microsecond to sub-microsecond, and to nanosecond, the target induced was from the outer membrane to inner membrane gradually. At the same time, the field intensity should be increased to induce corresponding bioelectric effects. Window effect provides theoretical guidance to choosing reasonable parameters for application of pulsatile electric field in tumor treatment.
Cell Membrane
;
physiology
;
radiation effects
;
Computer Simulation
;
Electromagnetic Fields
;
Humans
;
Membrane Potentials
;
physiology
;
radiation effects
;
Models, Biological
3.Focusing properties of picosecond electric pulses in non-invasive cancer treatment.
Zaiquan LONG ; Chenguo YAO ; Chengxiang LI ; Yan MI ; Caixin SUN
Journal of Biomedical Engineering 2010;27(5):1128-1132
In the light of optical theory, we advanc an ultra-wideband impulse radiating antenna (IRA) which is composed of an ellipsoidal reflector and a cone radiator. The high-intensity ultra-short electric pulses radiated by IRA can be transferred into the deep target in tissue non-invasively and be focused effectively. With the focused picosecond electric pulses, the organelles (mitochondria) transmembrane potential shall change to collapse under which the tumor cells will be targetly induced to apoptosis, so the method of non-invasive treatment of tumors would be achieved. Based on the time-domain electromagnetic field theory, the propagation characteristics of picosecond electric pulses were analyzed with and without the context of biological tissue, respectively. The results show that the impulse characteristics of input pulse were maintained and the picosecond electric pulses can keep high resolution in target areas. Meanwhile, because of the dispersive nature of medium, the pulse amplitude of the pulses will attenuate and the pulse width will be broadened.
Apoptosis
;
radiation effects
;
Electric Stimulation Therapy
;
methods
;
Electrodes
;
Electromagnetic Phenomena
;
Electroporation
;
methods
;
Humans
;
Neoplasms
;
pathology
;
therapy
4.The study of apoptosis and mechanism of cells exposed to steep pulse.
Huan LIU ; Liling TANG ; Caixin SUN ; Yan MI ; Chenguo YAO ; Chengxiang LI ; Yuanliang WANG
Journal of Biomedical Engineering 2008;25(3):637-641
This experiment was designed to study the apoptosis and related mechanism of adherent liver tumor cells (SMMC-7721) and adherent normal liver cells (HL-7702) when they were exposed to the steep pulse generated by the steep pulse apparatus for tumor treatment. The results showed that the steep pulse of 200 V could induce tumor cells apoptosis. The tumor cells presented with their apoptosis when they were exposed to the steep pulse from 200 V to 250 V. Laser scanning confocal microscopy was used to make a real time study of calcium burst when the adherent tumor cells were exposed to the steep pulse. The results showed:On the condition of no extracellular Ca2+, the concentration of Ca2+ in tumor cells exposed to the steep pulse of 150 V did not change; the concentration of Ca2+ in tumor cells exposed to the steep pulse of 200 V decreased; the concentration of Ca2+ in tumor cells exposed to the steep pulse of 250 V decreased more evidently. On the condition of existing extracellular Ca2+, the concentration of Ca2+ in tumor cells exposed to the steep pulse of 150 V did not change; the concentration of Ca2+ in tumor cells exposed to the steep pulse of 200 V decreased little; the concentration of Ca2+ in tumor cells exposed to the steep pulse of 250 V reduced little, too. Maybe the change of calcium burst in the tumor cells is the mechanism of apoptosis when cells are exposed to the steep pulse.
Apoptosis
;
radiation effects
;
Calcium
;
metabolism
;
Electricity
;
Electromagnetic Fields
;
Hepatocytes
;
cytology
;
pathology
;
Humans
;
Liver Neoplasms
;
metabolism
;
pathology
;
Microscopy, Confocal
;
Tumor Cells, Cultured
5.Relations of transcription expression of IL-2 with nuclear factor of activated T cells as well as changes of C-Fos and C-Jun after trauma.
Yan LUO ; Huaping LIANG ; Chengxiang HU ; Xiang XU ; Zhengguo WANG
Chinese Journal of Traumatology 2002;5(5):275-278
OBJECTIVETo observe the relations among expression of interleukin-2 (IL-2) in spleen lymphocytes, DNA binding activity of nuclear factor of activated T cells (NFAT) and expression of the partly family members C-Fos, C-Jun after trauma.
METHODSA murine closed trauma model was used, animals were sacrificed 6, 12 hours and 1, 4, 7, 10, 14 days, respectively after injury. Spleen lymphocytes were isolated from injured mice and stimulated with concanavalin-A. The culture supernatants were harvested and assayed for IL-2 activity. Total RNA was extracted from spleen lymphocytes and assayed for IL-2 mRNA. Nuclear protein was extracted, and the DNA binding activity of NFAT was measured using an electrophoretic mobility shift assay (EMSA), the expressions of C-Fos, C-Jun protein determined by Western blot analysis.
RESULTSThe expressions of IL-2 activity and IL-2 mRNA in spleen lymphocytes were decreased in injured mice compared with those in control mice, and the most obvious decrease appeared on the 4th day after injury. The DNA binding activity of NFAT decreased gradually and reached the minimum that was only 41% of the control on the 4th day after injury, which was closely associated with the decline of IL-2 activity and IL-2 mRNA. An decrease in the expression of C-Fos on the 1st and 4th day after injury, trauma had no significant effect on the C-Jun expression.
CONCLUSIONSThese results suggest that the inhibition of IL-2 expression is partly due to the impairment in the activation of NFAT in injured mice; and the decline in the DNA binding activity of NFAT is partly due to trauma block in the C-Fos expression.
Animals ; Blotting, Western ; DNA-Binding Proteins ; metabolism ; Electrophoretic Mobility Shift Assay ; Female ; Interleukin-2 ; metabolism ; Lymphocyte Activation ; physiology ; Male ; Mice ; NFATC Transcription Factors ; Nuclear Proteins ; Proto-Oncogene Proteins c-fos ; metabolism ; Proto-Oncogene Proteins c-jun ; metabolism ; Random Allocation ; T-Lymphocytes ; physiology ; Transcription Factors ; metabolism
6.Effect of negative pressure level on drain volume and prognosis of patients after prosthetic augmentation mammoplasty through inframammary fold incision
Haiyang ZHAO ; Ximei WANG ; Haijiang DONG ; Zhibin LI ; Baihui XIE ; Chengxiang YAN
Chinese Journal of Plastic Surgery 2023;39(4):375-383
Objective:To investigate the effect of different negative pressure level on drain volume after augmentation mammoplasty through inframammary fold incision, and try to put forward the appropriate negative pressure level for the best prognosis of patients.Methods:This was a randomized controlled clinical study. Patients who underwent prosthetic augmentation mammoplasty through inframammary fold incision in the Medical Beauty Center of the First Affiliated Hospital of Zhengzhou University from January 2019 to August 2021 were selected as the study subjects. Patients were divided into 4 groups by random number table method and different levels of negative pressure drainage were applied: 600 ml adjustable negative pressure drain bottle was used uniformly after operation by -80--85 kPa group, -40--60 kPa group, and -15--30 kPa group. In 0--5.2 kPa group, 300 ml drain drum was applied after operation. The criteria for drain removal was that the drain volume within 24 hours was less than 10 ml and the drainage fluid was clear. Daily drain volume, duration of drain placement, total drain volume, acceptance of the drain device and postoperative complications were recorded in the four groups. The corresponding indexes of each group were statistically analyzed by SPSS 21.0. Measurement data were expressed as Mean±SD. One-way analysis of variance was used for comparison between groups, and LSD- t test was used for pair comparison between groups. P<0.05 was considered statistically significant. Results:A total of 80 patients were included, 20 in each group. Inter-group equilibrium analysis: there was no significant difference in age, body mass index, distance from midclavicular point to nipple, distance from inferior mammary fold to nipple, and breast tissue thickness among 4 groups ( P>0.05). Evaluation of curative effect between groups: on the first and second day after operation, there was no significant difference in drain volume between -80--85 kPa group and -40--60 kPa group ( P>0.05), but there was significant difference among other groups ( P<0.05). There was significant difference in drain volume on the third day after operation, total drain volume and duration of drain placement between the four groups ( P<0.05). The lower the negative pressure level was, the less drain volume on the third day after surgery and the less total drain volume, and the shorter duration of drain placement. The duration of drain placement of the four groups were (5.6±0.7) d (-80--85 kPa group), (4.8±0.5) d (-40--60 kPa group), (4.0±0.5) d (-15--30 kPa group), and (3.2±0.4) d (0--5.2 kPa group), respectively. Safety evaluation: the complication rate of -80--85 kPa group, -40--60 kPa group, -15--30 kPa group and 0--5.2 kPa group were 2.5% (1/40), 2.5% (1/40), 0(0/40) and 15.0% (6/40), respectively. The complication rate of 0--5.2 kPa group was the highest. Investigation on the acceptance of the drainage device (no impact/dissatisfaction): 75 patients expressed dissatisfaction, with a dissatisfaction rate of 93.75%(75/80). Conclusion:In augmentation mammoplasty through inferior fold incision low negative pressure provides less drain volume, shorter drain placement. Negative pressure between -15 to -30 kPa is optimal.
7.Application of three-dimensional printing in cartilage tissue engineering
Shuying YU ; Yu LI ; Xinhao CHENG ; Yijun ZHANG ; Zheng LIU ; Chengxiang YAN ; Baihui XIE ; Ximei WANG
Chinese Journal of Plastic Surgery 2023;39(12):1277-1285
In the past decades, great progress has been made in cartilage regeneration. The traditional techniques for constructing tissue engineering cartilage scaffold mainly include pore agent method (or template method ) , phase separation method, gas foaming method, freeze-drying method , electrospinning method, etc. Cartilage is heterogeneous, and it is difficult for traditional scaffolds to simulate the high anisotropy of cartilage. Therefore, functional regeneration of cartilage is challenging. With the progress of three-dimensional (3D) printing technology, it is possible to prepare functional bionic scaffolds with fine structure and gradient changes through co deposition of biomaterials, cells and active biomolecules, so as to achieve functional cartilage regeneration. This article reviews 3D printing technology of cartilage tissue engineering, and the application of 3D printing technology in cartilage regeneration at different anatomical positions (articular cartilage, auricle cartilage, nasal cartilage) . In addition, the importance of preparing bionic constructs with regional structure gradient and regional composition gradient was discussed. 3D bioprinting technology, 4 D printing techniques, smart biomaterials brought hope for the construction of bionic tissues and organs.
8.Application of three-dimensional printing in cartilage tissue engineering
Shuying YU ; Yu LI ; Xinhao CHENG ; Yijun ZHANG ; Zheng LIU ; Chengxiang YAN ; Baihui XIE ; Ximei WANG
Chinese Journal of Plastic Surgery 2024;40(1):99-106
In the past decades, significant progress has been achived in cartilage regeneration. The traditional techniques for constructing tissue engineering cartilage scaffold mainly include pore agent method (or template method), phase separation method, gas foaming method, freeze-drying method, electrospinning method, etc. Cartilage is heterogeneous, and it is difficult for traditional scaffolds to simulate the high anisotropy of cartilage. Therefore, functional regeneration of cartilage is challenging. With the progress of three-dimensional(3D) printing technology, it is possible to prepare functional bionic scaffolds with fine structure and gradient changes through co-deposition of biomaterials, cells and active biomolecules, so as to achieve functional cartilage regeneration. This article reviewed 3D printing technology of cartilage tissue engineering, and the application of 3D printing technology in cartilage regeneration at different anatomical positions (articular cartilage, auricle cartilage, nasal cartilage). In addition, the importance of preparing bionic constructs with regional structure gradient and regional composition gradient was discussed. 3D bioprinting technology, 4D printing techniques, smart biomaterials brought hope for the construction of bionic tissues and organs.
9.Association of serum complement C3, C4 with renal pathological lesion degree in IgA nephropathy patients
Yufeng LI ; Jiao BAO ; Rong SUN ; Chengxiang HU ; Lu HAN ; Yan BAI
Chinese Journal of Nephrology 2023;39(6):422-427
Objective:To explore the relationship between the levels of serum complement C3 and C4 and the degree of renal pathological injury in patients with IgA nephropathy (IgAN).Methods:It was a retrospective study. The clinical and pathological data of patients with primary IgAN diagnosed by renal biopsy in the Department of Nephrology of the Second People's Hospital of Qujing City, Yunnan Province from December 1, 2019 to December 31, 2022 were collected. According to the IgAN Oxford classification criteria, the patients were divided into mild renal pathological injury group (mild group, <3 pathologic types) and severe renal pathological injury group (severe group, ≥3 pathological types). The levels of serum C3 and C4 and other clinical data were compared between the two groups. Spearman correlation method was used to analyze the correlation between serum C3, C4 levels and estimated glomerular filtration rate (eGFR) during renal biopsy.Multivariate logistic regression model was used to analyze the influencing factors of the pathological injury degree in IgAN patients and the forest map depicted the effect of risk factors.Results:A total of 164 IgAN patients were included in the study, including 77 males (47.0%), aged (35.5±12.9) years old. There were 60 patients in the mild group and 104 patients in the severe group. Compared with the mild group, the patients in the severe group were older, had higher levels of serum C4, serum uric acid, low density lipoprotein cholesterol and 24 h urinary protein, higher proportions of hypertension, glucocorticoids/immunosuppressant therapy, C3 deposition in renal tissues and microscopic hematuria, and had lower hemoglobin and serum C3 level (all P<0.05). The results of Spearman correlation analysis showed that the level of serum C3 was positively correlated with eGFR ( r=0.303, P<0.001), and the level of serum C4 was negatively correlated with eGFR ( r=-0.238, P=0.002). Multivariate logistic regression analysis results showed that serum C3 (every 0.01 g/L increase, OR=0.976, 95% CI 0.957-0.996, P=0.018), serum C4 (every 0.01 g/L increase, OR=1.091, 95% CI 1.020-1.166, P=0.011), hemoglobin ( OR=0.969, 95% CI 0.950-0.988, P=0.002), and serum uric acid ( OR=1.005, 95% CI 1.001-1.009, P=0.012) were independent related factors of renal pathological damage (severe injury /mild injury) in IgAN patients. Conclusions:Serum C3 and C4 are independent related factors of the severity of renal pathological injury in IgAN patients.
10.Effect of negative pressure level on drain volume and prognosis of patients after prosthetic augmentation mammoplasty through inframammary fold incision
Haiyang ZHAO ; Ximei WANG ; Haijiang DONG ; Zhibin LI ; Baihui XIE ; Chengxiang YAN
Chinese Journal of Plastic Surgery 2023;39(4):375-383
Objective:To investigate the effect of different negative pressure level on drain volume after augmentation mammoplasty through inframammary fold incision, and try to put forward the appropriate negative pressure level for the best prognosis of patients.Methods:This was a randomized controlled clinical study. Patients who underwent prosthetic augmentation mammoplasty through inframammary fold incision in the Medical Beauty Center of the First Affiliated Hospital of Zhengzhou University from January 2019 to August 2021 were selected as the study subjects. Patients were divided into 4 groups by random number table method and different levels of negative pressure drainage were applied: 600 ml adjustable negative pressure drain bottle was used uniformly after operation by -80--85 kPa group, -40--60 kPa group, and -15--30 kPa group. In 0--5.2 kPa group, 300 ml drain drum was applied after operation. The criteria for drain removal was that the drain volume within 24 hours was less than 10 ml and the drainage fluid was clear. Daily drain volume, duration of drain placement, total drain volume, acceptance of the drain device and postoperative complications were recorded in the four groups. The corresponding indexes of each group were statistically analyzed by SPSS 21.0. Measurement data were expressed as Mean±SD. One-way analysis of variance was used for comparison between groups, and LSD- t test was used for pair comparison between groups. P<0.05 was considered statistically significant. Results:A total of 80 patients were included, 20 in each group. Inter-group equilibrium analysis: there was no significant difference in age, body mass index, distance from midclavicular point to nipple, distance from inferior mammary fold to nipple, and breast tissue thickness among 4 groups ( P>0.05). Evaluation of curative effect between groups: on the first and second day after operation, there was no significant difference in drain volume between -80--85 kPa group and -40--60 kPa group ( P>0.05), but there was significant difference among other groups ( P<0.05). There was significant difference in drain volume on the third day after operation, total drain volume and duration of drain placement between the four groups ( P<0.05). The lower the negative pressure level was, the less drain volume on the third day after surgery and the less total drain volume, and the shorter duration of drain placement. The duration of drain placement of the four groups were (5.6±0.7) d (-80--85 kPa group), (4.8±0.5) d (-40--60 kPa group), (4.0±0.5) d (-15--30 kPa group), and (3.2±0.4) d (0--5.2 kPa group), respectively. Safety evaluation: the complication rate of -80--85 kPa group, -40--60 kPa group, -15--30 kPa group and 0--5.2 kPa group were 2.5% (1/40), 2.5% (1/40), 0(0/40) and 15.0% (6/40), respectively. The complication rate of 0--5.2 kPa group was the highest. Investigation on the acceptance of the drainage device (no impact/dissatisfaction): 75 patients expressed dissatisfaction, with a dissatisfaction rate of 93.75%(75/80). Conclusion:In augmentation mammoplasty through inferior fold incision low negative pressure provides less drain volume, shorter drain placement. Negative pressure between -15 to -30 kPa is optimal.