1.Percutaneous cannulate screw fixation in treating the traumatic diastasis of the pubic symphysis
Chengdi SHI ; Xiaoshan GUO ; Wei HU ; Kehe YU
Chinese Journal of Orthopaedics 2011;31(11):1218-1222
ObjectiveTo study the technique and therapeutic effect of percutaneous cannulate screw fixation to treat the traumatic diastasis of the pubic symphysis.MethodsFrom February 2003 to December 2010,46 patients (27 men and 19 women,mean age of 34.6 years) with unstable pelvic fractures and diastasis of the pubic symphysis were admitted.All the patients were treated by closed reduction and percutaneous cannulate screw fixation of the symphysis pubis.Then to complete the fixation of posterior ring,by percutaneous screw inserted through the sacroiliac joint or posterior iliac wing.According to Tile's classification,the patients were classified into type B1.1 in 4 cases,B1.2 in 7,B2 in 2,B3 in 2,C1.1 in 7,C1.2 in 7,C1.3 in 10,C2 in 5 and C3 in 2.All patients were performed posterior ring fixation except 4 cases of type B1.1.Anteroposterior,inlet and outlet X-ray radiographs and CT scans of the pelvis were taken preoperatively to evaluate the stability and deformities,and after surgery the plain radiographs and CT scans were taken to evaluate the reduction and the location of screws.ResultsThe average operative time was 45 min (range,15-65 min),and the average intraoperative blood loss was 25 ml (range,15-50 ml).Each patient was inserted one screw in the symphysis pubis.Thirty-five patients underwent postoperative pelvic CT scan and 3screws of them penetrated the wall of symphysis pubis.The average follow-up period was 23.5 months (range,5-48 months).In the follow-up period,no infection and displacement were found.The last follow-up result:according to Matta and Tornetta's standard,the result was excellent in 43 cases and good in 3.Among all patients,31 cases (67.39%) had returned to their original works,6 were to give up their original works as complicating injuries; 28 cases had no pain,13 cases had slight pain of the symphysis pubis while to make an effort,5 cases had pain of sacroiliac joint.There were no iatrogenic injury of nerve.ConclusionClosed reduction and percutaneous cannulate screw fixation of the traumatic diastasis of the pubic symphysis is a safe,feasible and easy manipulated method.The operative injuries is small and the clinical outcome is satisfactory.
2.Treatment of open pelvic fracture concomitant with perineal laceration using external fixation combined with limited percutaneous internal fixation plus colostomy
Xiaoshan GUO ; Chengdi SHI ; Junwu HUANG ; Lei YANG ; Jianzhong KONG
Chinese Journal of Trauma 2011;27(4):304-306
Objective To introduce the methods and key points for the external fixation combinel with limited percutaneous internal fixation plus colostomy in the treatment of open pelvic fracture concomitant with perineal laceration.Methods Nine patients with open pelvic fractures concomitant with perineallaceration were treated by external fixator combined with limited percutaneous internal fixer plus colostomy. Data including injury details, management and outcomes were collected for comparison.Results All the patients survived and attained bony union except for two patients with local infection that was healed several days after repeated wound debridement and use of wide spectrum antibiotics. All the patients had good extremity function at the latest follow-up. Conclusion External fixation combined with limited percutaneous internal fixation plus colostomy is a reliable, safe and less invasive procedure for the treatment of open pelvic fractures concomitant with perineal open wound.
3.X-ray diagnosis method for three-dimensional displacement of unstable pelvic fractures and its preliminary application in closed reduction
Chengdi SHI ; Wei HU ; Kehe YU ; Jianshun WANG ; Xiaoshan GUO
Chinese Journal of Trauma 2013;29(8):717-722
Objective To investigate the methods of X-ray diagnosis of various displacement of unstable pelvic fracture in three-dimensional space and its instructive significance in closed reduction.Methods A normal adult pelvic specimen was selected and fixed in a wood-frame at supine position after soft tissue rejection and ligament preservation.With the breakage at the unilateral anterior-posterior ring,models of hemipelvic rotation in the transverse and sagittal planes and hemipelvic vertically upward displacement were induced.Anteroposterior radiographs of the pelvic specimen were made and picture archiving and communication system (PACS) was used to measure width of iliac wing,suprainferior diameter of hemipelvis,vertical displacement of iliac crest,acetabulum roof,pubic tubercle and sciatic tuber and area of obturator foramen.Methods of X-ray diagnosis of various displacements of hemipelvis were concluded and applied in treatment of 43 patients with unstable pelvic fractures.Operation time and intraoperative blood loss were recorded.Postoperative images were evaluated by Matta standard.Results Hemipelvic rotation in transverse plane included eversion and inversion.Width of iliac crest was enlarged and area of obturator foramen was shrunk while extroversion ; on the contrary,an opposite result was observed while inversion.Sagittal rotation included pronation and supination.Pubic tubercle had obvious downward shift,iliac crest presented no change or slight upward shift,suprainferior diameter of hemipelvis was lengthened,iliac roof and sciatic tuber remained their position unchanged and area of obturator foramen was shrunk while pronation; on the contrary,pubic tubercle had obvious upward shift,iliac crest presented no change or slight downward shift,suprainferior diameter of hemipelvis was shortened,iliac roof and sciatic tuber remained their position unchanged and area of obturator foramen was enlarged while supination; iliac crest,acetabular roof,pubic tubercle and sciatic tuber presented equidistant upward shift while the hemipelvis displaced upward vertically.Average operation time was 55 minutes (range,15-85 minutes) and intraoperative blood loss was 26 ml (range,10-50 ml).According to Matta standard,pelvic radiography evaluation at postoperative 3 days was excellent in 31 cases and good in 12 cases,with excellent and good rate of 100%.Conclusion Pelvis X-ray films are able to diagnose various three-dimensional displacement of unstable pelvic fractures and guide closed reduction timely and rapidly to achieve satisfactory result.
4.Limited internal fixation combined with external fixation for comminuted humerus shaft fractures
Junwu HUANG ; Yulong ZHOU ; Yifei ZHOU ; Zhenxing LI ; Chengdi SHI ; Xiaoshan GUO
Chinese Journal of Trauma 2016;32(8):683-687
Objective To evaluate the clinical outcome in the treatment of humerus shaft comminuted fractures using limited open reduction and internal fixation combined with an external fixator.Methods Data of 80 patients with comminuted humerus shaft fractures treated from January 2005 to January 2013 were analysed retrospectively.All the patients underwent limited open reduction and internal fixation combined with an external fixator (treatment group) and open reduction and plate fixation (control group) according to the random number table.In the treatment group,there were 40 patients (28 males,12 females),at mean age of 33.5 years (range,21-54 years),with causes of injury including traffic accidents in five patients,falls in nine,crashes in seven and others in six.There were seven patients with open fractures and 33 with closed fractures.In the control group,there were 40 patients (25 males,15 females),at mean age of 32.9 years (range,19-55 years),with causes of injury including traffic accidents in 16 patients,tumbling in seven,crush in seven and others in ten.There were eight patients with open fractures and 32 with closed fractures.The operation time,intraoperative blood loss,bone union time and complications in both groups were recorded.Clinical efficacy was evaluated using the Stewart and Hundley standard.Results Mean follow-up was 19 months (range,15-24 months).Treatment and control groups showed significant differences in operation time [(55.5 ± 10.3) minutes vs.(120.5 ± 15.3) minutes],intraoperative blood loss [(120.4 ± 20.7) ml vs.(245.4 ± 26.7) ml] and bone union time [(11.6 ± 1.3) weeks vs.(14.9 ± 2.3) weeks] (P < 0.05).Rate of incision infection was 8% (3/40) in treatment group and 10% (4/40) in control group (P > 0.05).In treatment group the results were excellent in 31 patients and good in nine.In control group the results were excellent in 27 patients,good in nine,fair in one and poor in three.One patient with radial nerve injury after a second surgery for implant removal and two patients with osteomyelitis or bone nonunion were noted in control group.Conclusion Limited open reduction and internal fixation in combination with an external fixator is associated with small trauma,easy operation,short operation time,few bleeding,rigid fixation,early functional exercises and reduced bone nonunion for treatment of comminuted humerus shaft fractures,which exhibits great clinical value.
5.Prodrug structural modifications of cyclovirobuxine D and their biological activity.
Lan DENG ; Heng HUANG ; Ming-Xia XU ; Shi-Qing ZHOU ; Fang REN ; Xing-Wen WANG ; Dai-Qing LI
Acta Pharmaceutica Sinica 2005;40(9):820-824
AIMTo search for compounds for the treatment of cardiovascular diseases through prodrug structural modifications of cyclovirobuxine D, a single efficient composition distilled from Box plant in China, which was used to treat angina and myocardial infarction.
METHODSAccording to prodrug design principle, a series of cyclovirobuxine D analogues were prepared, suc as succinate, phosphate and amino acid ester, and their biological activities were tested.
RESULTSSeven new compounds were obtained and confirmed with 1H NMR, MS, and element analysis.
CONCLUSIONIn pharmacology experiment, for treating arrhythmia induced by aconitine, succinate and amino acid ester of cyclovirobuxine D (I and VII) showed better activities than that of cyclovirobuxine D. The normal rhythm of the heart duration of I and VII were ( 11.53 +/- 7.62) min and (12.68 +/- 9.25) min, compared with 0.9% NaCl solution and cyclovirobuxine D, (2.36 +/- 1.68) min and (10.25 +/- 6.59) min (P < 0.01), respectively. Another pharmacology experiment, for treating arrhythmia induced by chloroform, the negative ratio of I and VII were 80% and 82%, compared with 0.9% NaCl solution and cyclovirobuxine D, 43% and 52% (P < 0.05), respectively. The difference between new compounds and cyclovirobuxine D was distinct.
Aconitine ; Animals ; Anti-Arrhythmia Agents ; chemical synthesis ; pharmacology ; Arrhythmias, Cardiac ; chemically induced ; physiopathology ; Buxus ; chemistry ; Chloroform ; Drugs, Chinese Herbal ; chemical synthesis ; pharmacology ; Female ; Heart Rate ; drug effects ; Male ; Mice ; Plants, Medicinal ; chemistry ; Prodrugs ; chemical synthesis ; pharmacology ; Random Allocation ; Rats ; Rats, Sprague-Dawley