3.Effect of epigallocatechin gallate against exercise-induced fatigue in mice.
Cheng-yin WANG ; Jian-hua PAN ; Hui LI
Chinese Journal of Applied Physiology 2015;31(1):85-88
OBJECTIVETo investigate the effects of epigallocatechin gallate (EGCG)against exercise-induced fatigue in mice.
METHODSTotal 120 mice were randomly divided into three groups and tested separately. For each test, there were 30 mice subdivided into high dose (50 mg/kg . d EGCG) and low dose (10 mg/kg . d EGCG) groups as well as saline control group(1 ml/kg . d) with 10 in each. Burden swimming, running wheel endurance, stick climbing and hypoxia tolerance exercise were used to establish fatigue mice training model in three groups. And intraperitoneal injection with different doses of EGCG per day for consecutively 28 days and the mice in the control group were treated with normal saline. After the last each test, the blood lactic acid (BLA), blood urea nitrogen (BUN), blood lactate dehydrogenase (LDH), muscle glycogen (MG) and liver glycogen (LG) of each group of mice were determined.
RESULTSEGCG treatment groups(B and C)revealed a prolonged the mice survival time of burden swimming test, hypoxia tolerance, running wheel time and the ability of stick climbing(P < 0.05 or P <0.01), and increased LDH activity and MG and LG contents, reduced contents of BLA and BUN. High dose group had an obviously increase effect than lower dose group(P <0.05).
CONCLUSIONEGCG has significant effects against exercise-induced fatigue in mice.
Animals ; Blood Urea Nitrogen ; Catechin ; analogs & derivatives ; pharmacology ; Exercise Tolerance ; Fatigue ; drug therapy ; Glycogen ; metabolism ; L-Lactate Dehydrogenase ; blood ; Mice ; Physical Conditioning, Animal
4.Strategy to delay the progression of chronic kidney disease by targeting gut microbiota and uremic toxins metabolism pathway
Yin PENG ; Xue-jun XU ; Jian-ping LI ; Cheng-xi LI ; Jia-ting YIN ; Jin-ao DUAN ; Jian-ming GUO
Acta Pharmaceutica Sinica 2021;56(1):37-49
Chronic kidney disease (CKD) is a serious chronic disease with high incidence, poor prognosis, and a variety of complications. Indoxyl-sulfate (IS) and
5.Comparison of biological characteristics of mesenchymal stem cells derived from bone marrow, peripheral blood and cord blood
Youzhang HUANG ; Jianliang SHEN ; Lizhong GONG ; Wenjie YIN ; Yi LIU ; Hai CHENG ; Peihao ZHENG ; Jian CEN
Chinese Journal of Tissue Engineering Research 2009;13(45):8966-8970
BACKGROUND:Mesenchymal stem cells (MSCs) exist in human tissues.Presently,cell source is single;culture method has great differences;obtained results are not consistent.Thus,it cannot verfy that isolated and cultured cells are identical calls,which is difficult to compare.OBJECTIVE:To compare the biological features of MSCs derived form bone marrow (BM),perpheral blood (PB) and cord blood (CB) under in vitro culture conditions.DESIGN,TIME AND SETTING:The cytological in vitro controlled study was performed at the Department of Hematology,Navy General Hospital of Chinese PLA from June 2007 to December 2008.MATERIALS:A total of 10 donors of hemopoietic stem cell transplantation at the Department of Hematology,Navy General Hospital of Chinese PLA were selected.MB and PB cells were obtained from the same donor,and cell volumes were respectively 20 mL and 2 mL.CB cells (30 mL) were obtained from healthy primipara at the Department of Obstetrics,Navy General Hospital of Chinese PLA.METHODS:MSCs were obtained from BM,PB and CB by Percoll density gradient + adherence method,and then incubated in DMEM/F12 medium containing 10% fetal bovine serum.When 80%-90% confluency,cells were digested in trypsin-EDTA and made into 5×10~8/L cell suspension as P_0.Above-described operation was performed as P_1,and the rest may be deduced by analogy as P_2-P_5.MAIN OUTCOME MEASURES:The following parameters were measured:cell growth morphology;results of Wright-Giemsa staining;results of cytochemistry;cell proliferation amount;cell surface markers using flow cytometry.RESULTS:Time of adherence,time to 50% confluency and time to 80% confluency of BMSCs were earlier comarped with the PBMSCs and UCMSCs.Adherent cells from BM grew in whirpool-like type,while CB and PB did not at 5-7 days.Majority of aderent cells from BM were fibroblast-like cells,and small parts were endothelioid cells.Aderent cells from PB and CB at the fifth generation contained more endothelioid cells and mononuclear and macrophage-like cells besides fibroblast-like cells.PAS stain,Sudan black B stein,alkaline phosphatase (AKP) staining of adherent cells from BM,PB and CB were negative from P_1 to P_5.Compared with P0 cells,number of BMMSCs till P5 was significantly more in PBMSCs and UCMSCs (P < 0.05).Positive rates of CD29,CD44,CD90,CD71,CD105,CD166 and HLA-ABC were 55.9% 92.8% at P0 to P5,but ≤6% following BMMSCs were incubated;19.7%-33.4% at P0 to P5,but ≤10% following PBMSCs were incubated;35.4%-93.2% at P_0 to P_5,but ≤20% following CBMSCs were incubated.Positive rates of CD34,CD45 and HLA-DR were low in BM-,PB-and CB-MSCs.Positive rates of CD14 and CD31 were low in BMMSCs;12.1%-28.3% in PBMSCs,and 8.1%-21.3% in CBMSCs.CONCLUSION:MSCs can be attained from BM,PB and CB.Quantities of MSCs form BM are the highest,with single component,followed by CBMSCs and PBMSCs,with multiple components.
6.Analysis of multi-leaf collimator leaf position deviation in volumetric modulated arc therapy
Chengqiang LI ; Cheng TAO ; Jian ZHU ; Jie LU ; Tonghai LIU ; Yong YIN
Chinese Journal of Radiological Medicine and Protection 2016;36(12):904-908
Objective To evaluate the position deviation of multi-leaf collimator (MLC) in volumetric modulated arc therapy for nasopharyngeal carcinoma and to verify a method of detecting the leaf position accuracy.Methods Thirty-two volumetric modulated arc plans of nasopharyngeal carcinoma were randomly selected.A clockwise arc with a gantry range of 181° to 179° and a counterclockwise arc with a gantry range of 179° to 181° were uscd for each plan.Each arc contained two leaf groups,groups A and B.By using the Argus software,the actual MLC leaf positions were extracted from the Dynalog files in the Varian Trilogy accelerator.The planed MLC leaf positions were compared with the actual positions,and the differences were calculated between them.Results The proportions of the leaf position errors within ± 2,± 1.5,± 1 and ± 0.5 mm were 99.99%,99.90%,99.07% and 93.98%,respectively.The proportions of the leaf position errors within ± 1 mm were 98.08%,100%,98.97% and 99.01% for the first therapeutic arc (ARC1),second therapeutic arc (ARC2),A and B groups,respectively.The leaf position errors range of ARC1 and ARC2 were-2.95 to 2.99 and-0.22 to 0.23 mm (t =2.35,P < 0.01).The leaf position errors range of leaf bank A and leaf bank B were-2.95 to 2.68 and-2.92 to 2.99 mm(P > 0.05).Conclusions During the volumetric modulated arc radiotherapy,the leaf positions deviation are in control.The Dynalog files can be used as an effective way to analysis the leafposition errors.
7.Efficiency comparison of preparing nano-scale microbubbles by oscillation and sonication
Jian ZHENG ; Ping WANG ; Tinghui YIN ; Bowen ZHENG ; Du CHENG ; Rongqin ZHENG
Chinese Journal of Ultrasonography 2012;(12):1078-1081
Objective To compare the efficiency of oscillation with sonication in preparing nano-scale microbubbles (NBs).Methods Nano-scale microbubbles were prepared using oscillation and sonication respectively,and then compared the NBs' size,size distribution,concentrations and time-consumption of the two methods.Results The sizes of nanobubbles prepared by sonication and oscillation were (373.88 ±18.43)nm and (360.74 ± 14.39)nm,respectively.There was no significant difference in size between the two methods (P =0.523).The polidispersity was larger in sonication before centrifugation,there was significant difference between the two methods (P <0.001).The concentration of nanobubbles prepared by oscillation was (1.48 ± 0.15) × 1010,which was higher than that by oscillation [(8.07 ± 0.62) × 108],there was significant difference between the two methods (P < 0.001).The consuming time was shorter in oscillation,the difference was significant when compared with sonication (P <0.001).Conclusions Both two methods can successfully prepare NBs.Compared with sonication,oscillation can effectively produce NBs with smaller polidispersity,higher concentration and shorter time-consumption.
8.Changes of Hematoxin,Lipopolysaccharide,Lipopolysaccharide Binding Protein/Membrane CD_(14) in Children with Systemic Inflammatory Response Syndrome
dong-ming, SUN ; ya-ying, CHENG ; li-juan, JING ; jian-ying, YIN
Journal of Applied Clinical Pediatrics 1992;0(06):-
Objective To investigate the effect of hematoxin,lipopolysaccharide(LPS),lipopolysaccharide binding protein(LBP)/membrane CD14(mCD14) in occurrence and development of systemic inflammatory response syndrome(SIRS) in children.Methods Serum LPS,LBP,mean fluorescence intensity(MFI) of mCD14 on monocytes of 30 patients with SIRS were measured,at the same time 21 healthy children had been chosen to serve as control group.Results Compared with control group,the serum LPS,LBP,MFI of mCD14 on monocytes of patients with SIRS were significantly higher(Pa
9.Change of Serum Macrophage Inflammatory Protein-1? in Newborn Infants with Hypoxic-Ischemic Encephalopathy
jing, CAO ; wei-hua, CHEN ; qiu-jin, LIANG ; ya-ying, CHENG ; jian-ying, YIN
Journal of Applied Clinical Pediatrics 1986;0(02):-
Objective To explore the roles of macrophage inflammatory protein-1?(MIP-1?)in hypoxic-ischemic encephalopathy(HIE)of newborn infarnts.Methods Serum samples were obtained in 24,72 h and 7 d after birth respectively from 34 newborn infants with HIE,and 20 newborn infants without HIE as control group.Enzyme-linked immunosorbent assay(ELISA)method was used to determine the serum concentrations of MIP-1?.Results Levels of MIP-1? in newborn infants with HIE [(12.47?2.51)ng/L]were significantly higher than that of newborn infants without HIE [(8.63?2.63)ng/L](P0.05).Conclusions MIP-1? are involved in HIE of neonates,and the more severe damage,the higher levels in serum,which suggests that,as an inflammatory mediator,the MIP-1? may play an important role in involvement of brain hypoxic-ischemic damage.
10.Application of dextroscope system in clinical education of thyroid disease
Bao-yin LIU ; Wen LUO ; Cheng-yu LUO ; Jian ZHANG ; Chun-zi HAN ; Yu ZHANG
Chinese Journal of Medical Education Research 2011;10(9):1096-1098
Dextroscope workstation is an advanced equipment developed in recent years and isused to make virtual reality model.We not only used it in surgical planning of thyroid disease,but also applied it in clinic teaching.Application of Dextroscope virtual reality system can help to improve students'capabilities of clinical thoughts and clinical techniques,stimulate their learning interest,enlarge the knowledge,shorten learning curve and release the conflict in practice.Dextroscope system will push forward the progress of education reform,so it is worth spreading.