1.Analysis of the pollution status of paralytic shellfish poisons in shellfish sold in Hainan Province, 2018-2021
LI Cheng ; XIAO Wen-lin ; YE Hai-mei ; LAI Xuan-cheng ; SHI Hui ; HE Chang-hua
China Tropical Medicine 2023;23(5):484-
Abstract: Objective To investigate the pollution of paralytic shellfish poisons (PSP) in shellfish sold in Hainan Province from 2018 to 2021. Methods From 2018 to 2021, the content of 10 paralytic shellfish poisons including saxitoxin (STX), neosaxitoxin (neoSTX), gonyautoxins 1 (GTX1), gonyautoxins 2 (GTX2), gonyautoxins 3 (GTX3), gonyautoxins 4 (GTX4), gonyautoxins 5 (GTX5), decarbamoylsaxitoxin (dcSTX), decarbamoylgonyau toxins 2 (dcGTX2) and decarbamoylgonyau toxins 3 (dcGTX3) in 7 kinds of shellfish commonly sold in 13 cities and counties in Hainan province was analyzed. Results The detection rate of PSP in 360 shellfish samples was 10.3%. Among them, the highest detection rate of STX was 5.83%, followed by GTX2 detection rate of 4.17%; the detection rate of neoSTX and GTX3 were both 1.67%; the detection rate of GTX1 was 1.39%. None of the five PSP, GTX4, GTX5, dcSTX, dcGTX2 and dcGTX3, were detected. Four types of PSP were detected in fanscallops, two were detected in oysters, mussels and Scapharca subcrenata, only one was detected in scallops, and no toxin contamination was detected in clams and razor clams. A single sample of fanscallops detected a maximum of 4 PSP, and a single sample of oysters, scallops, mussels and Scapharca subcrenata detected a maximum of 1 PSP. The equivalence of PSP in all samples was ND-155.6 μg/kg.The annual detection rate of PSP from high to low was: 20.0% in 2020, 15.6% in 2019, 5.3% in 2018, and 2.0% in 2021, and none of the samples tested exceeded the standard. Continuously detectable STX in 2018-2020, all PSP that could be detected in 2018 were STX. In 2019, in addition to STX detected in scallops and Scapharca subcrenata, neoSTX was also detected in oysters, mussels and Scapharca subcrenata. In 2020, PSP was only detected from scallops, and GTX2 could be detected in all positive specimens, while 5 STX, 5 GTX1 and 6 GTX3 were detected. Only GTX2 detected from scallops in 2021. STX was detected in shellfish sold in 12 cities and counties, GTX2 can be detected in 10 cities and counties, neoSTX can be detected in 5 cities and counties, GTX1 and GTX2 were detected in 4 cities and counties respectively. Shellfish sold in Wenchang and Lingshui markets can detect 5 types of PSP. Conclusion Some types of shellfish on the market in Hainan are contaminated with some kind of PSP pollution risks, and it is necessary to strengthen the supervision of PSP in marketed shellfish.
2.A rabbit model of cervical spondylosis established by stimulation of wind, cold and dampness
Yongjun WANG ; Qi SHI ; Quan ZHOU ; Chenguang LI ; Jiangming CHENG ; Mei LIU ; Yang YANG ; Chongjian ZHOU
Journal of Integrative Medicine 2007;5(1):39-44
OBJECTIVE: To make an animal model of cervical spondylosis (arthralgia syndrome type) with stimulation of wind, cold, and dampness. METHODS: Twenty-four 8 months old male New Zealand white rabbits were randomly allocated into four groups: normal control group, light stimulation group, moderate stimulation group and severe stimulation group. The wind speed was 10.8-13.8 m/s, the temperature was (5+/-0.5)degrees centigrade, and the humidity was 100%. The rabbits of light, moderate, and severe stimulation groups were kept in the above-mentioned environments for 4 hours everyday, and for a total of 32, 64, and 128 hours, respectively. The intervertebral discs were stained with HE method, and observed with a light microscope. Prostaglandin E(2) (PGE(2)), 6-ketone-prostaglandin F1alpha (6-K-PGF(1alpha)) and thromboxane B(2) (TXB(2)) contents were measured by ELISA. Fas and Bcl-2 expressions were examined by immunohistochemical avidin-biotin peroxidose complex technique. Interleukin-1beta (IL-1beta), tumor necrosis factor alpha (TNF-alpha), and transforming growth factor beta (TGF-beta) mRNA expressions were examined by reverse transcription-polymerase chain reaction. RESULTS: The nucleus pulposus of rabbits in the light and moderate stimulation groups shrunken, and in the severe stimulation group, the anulus fibrosus loosed or ruptured, and the cartilage end-plate became proliferated. Compared with rabbits in the normal control group, the PGE(2) content rose in the light stimulation group, the contents of PGE(2), 6-K-PGF(1alpha), and TXB(2) increased, the expressions of IL-1beta and TNF-alpha mRNAs and Fas were up-regulated, and the expressions of TGF-beta mRNA and Bcl-2 were down-regulated in the moderate and severe stimulation groups. The expression of Fas was up-regulated mostly and Bcl-2 was down-regulated mostly in the severe group. CONCLUSION: Moderate and severe stimulations of wind, cold and dampness can lead to degeneration of cervical intervertebral discs of rabbits. The model corresponds to the theory of traditional Chinese medicine about arthralgia syndrome caused by wind, cold and dampness.
4.Comparison of anterior chamber depth and central corneal thickness measuring values between Sirius and Pentacam
Yan, LI ; Shi-ming, CHENG ; Xin, YANG ; Jin-hai, HUANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(3):262-265
Background Biometry of the anterior ocular segment parameter is very important for the diagnosis and treatment of glaucoma and ocular injury as well as measurement of intraocular lens(IOL).Objective This study was to compare the differences in the anterior chamber depth(ACD) and the central corneal thickness (CCT) between Sirius and Pentacam and evaluate the agreement of these two measurement methods.Methods The ACD and the CCT of 38 right eyes from 38 health volunteers aged 23- 32 years were measured with both Pentacam and Sirius.Three times of measurement were pedormed on each eye for each method to obtain the average values.The repeatability and agreement from each method were assessed as intraclass correlation coefficient( ICC ) and coefficient of variation(CV) and the agreement between these two methods were evaluated using Bland-Altman mode.ResultsThe mean ACD value was( 3.18±0.21 ) mm from Pentacam with the ICC 0.995 and CV 0.066.The mean ACD value from Sirius was (3.22 ±0.21 )mm with the ICC 0.996 and CV 0.065.The difference value in ACD between two methods was 0.04 mm,showing a significant difference( t =-6.225,P<0.05 ) and a positive correlation (r=0.977) between two methods.The 95% limit of agreement was( -0.04-0.13)mm within 1 standard difference (SD) of the mean value( ±0.21mm),which was acceptable for clinical measurement.The CCT was( 535±33 )μm from Pentacam with the ICC 0.994 and CV 0.062.The CCT was(537±36)pm from Sirius with the ICC 0.999 and CV 0.067.The difference value in the CCT between two methods was about 2 μm,presenting a in significant difference ( t =1.771,P>0.05 ) and positive correlation ( r =0.985 ).The 95 % limit of agreement was ( - 11.64-15.65 ) μm within 1 SD of the mean value( ±34.27 pm),which was acceptable for clinical measurement.ConclusionsSirius and Pentacam show good agreement in the measurement of ACD and CCT.The two methods offer an alternative choice for the biological measurement of the anterior ocular segment.
5.Comparison of axial length and anterior chamber depth measurements by IOLMaster, Axis- Ⅱ A-scan and ODM 1000A sonograph
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2011;29(11):1023-1026
Background Axial length and anterior chamber depth are important parameters for the calculation of diopter of intraocular lens ( IOL ). Objective This study was to investigate and compare the measuring outcomes of axial length and anterior chamber depth with IOLMaster,Axis- Ⅱ A-scan and ODM 1000A sonograph.Methods This a observational study.Axial length and anterior chamber depth were measured in 83 eyes of 48 patients with IOLMaster,Axis-Ⅱ A-scan and ODM 1000A sonograph by the same operator.The measuring results were compared among the three methods.Results The axial length were(25.79±0.85) mm,(25.72± 0.82 )mm and ( 26.00 ±0.83 )mm respectively with Axis- Ⅱ,ODM 1000A sonograph and IOLMaster.The difference between Axis-Ⅱ and DM 1000A sonograph was (0.07 ± 0.35 )mm without statistical difference between them (t=1.711,P =0.091 ).The difference of axial length between IOLMaster and DM 1000A sonograph was ( 0.27 ±0.29) mm with a statistical difference between them ( t =-8.570,P =0.000 ).The difference between IOLMaster and Axis- Ⅱ was (0.21 ±0.32 ) mm and showed a statistical difference ( t =- 5.931,P < 0.01 ).The positive correlations were found in the axial length values by the each other comparison among the three instruments( r=0.916,0.938,0.928,P<0.01 ).The anterior chamber depth values were ( 3.81 ±0.21 ) mm,( 3.84 ±0.25 ) mm and ( 3.83 ±0.18 )mm respectively with Axis-Ⅱ,0DM 1000A sonograph and IOLMaster.The difference of anterior chamber depth between Axis- Ⅱ and DM 1000A was (0.03 ±0.17 ) mm without statistical difference between them ( t =- 1.324,P =0.189 ).The difference in the anterior chamber depth between IOLMaster and DM 1000A was (0.01 ±0.15 ) mm and that between IOLMaster and Axis-Ⅱ was( 0.01 ±0.12)mm without any statistical differences among them (t =0.815,P=0.417 ;t=-0.900,P=0.371 ).The high correlation between anterior chamber depth measurements were found by the each other comparison in the three instruments ( r =0.735,0.813,0.823,P < 0.01 ).Conclusions ODM 1000A sonograph can provide precise axial length and anterior chamber depth values.However,ODM 1000Asonograph can not substitute for IOLMaster in the measurement of the anterior chamber depth and axial length.
6.Comparison among different noncontact specular microscopes for the detection of corneal endothelial cell density
Shi-ming, CHENG ; Jin-hai, HUANG ; Yan, LI ; Xin, YANG ; Rong-rong, GAO ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2012;30(2):150-154
Background Clinical research showed that the corneal endothelial cell density value from different corneal specula microscopies exist diversity.The relevant literature of SP02,Tomey EM-3000 and SP3000P is still seldom up to now. Objective This research was to assess the repeatability of endothelial cell density measurements by SP02,Tomey EM-3000 and SP3000P respectively and the agreement among 3 kinds of endothelial microscopes.MethodsFifty-four healthy volunteers with the age 17-38 years old were included this research.The written informed consent was obtained from each subject before examination.The corneal endothelial cell densities in the right eyes were analyzed with SP02,Tomey EM-3000 and SP3000P respectively for 3 times under the automatic mode,and the analytical procedure of SP3000P measurement were divided into automatic mode SP3000P (A) and manual correction modes SP3000P( M).The repeatability of each specula microscopy was analyzed by calculating the intraclass correlation coefficients (ICC) and coefficient of variation ( CV ),and the 95% confidence intervals and plotting Bland-Altman graphs were used to analyze the agreement among these methods.ResultsThe mean corneal endothelial cell densities in the population <24 years were significantly higher than the ones ≥ 24 years (t =3.692,P<0.05 ),but no statistical difference was found between different gender ( t =0.335,P =0.739 ).The mean corneal endothelial cell densities were ( 3058 ± 260 ),( 2954 ± 229 ),( 2668 ± 258 ),( 2734 ± 268 ) cell/mm2 ; the ICCs were 0.957,0.940,0.972 and 0.972 and the CV were 0.063,0.061,0.056,0.058 for SP02,Tomey EM-3000,SP3000P (A) and SP3000P ( M ) respectively.The 95% confidence intervals were ( - 100.8 - 306.8 ),( 162.6 - 617.4 ),( 109.9-494.1 ) and ( -0.6 - 132.6 ) cell/mm2 for between SP02 and Tomey EM-3000,SP3000P ( A ) and SP02,SP3000P(A) and Tomey EM-3000,SP3000P(A) and SP 3000P(M) respectively.ConclusionsSP02,Tomey EM-3000 and SP3000P(A) have good repeatability in the measurement of corneal endothelial cell density,however the outcome is different.Therefore,it is not interchangeable for the detection of corneal endothelial cell density.The differences of corneal endothelial cell density obtained from these instruments shall be paid high attention for their differences.SP3000P(A) and SP3000P(M) can be used interehangeably and SP3000P(A) is a preferable choice due to its convenience and quickness.
7.Comparison of anterior segment measuring parameters in myopia after laser in situ keratomileusis between Sirius and Pentacam
Zhen, XU ; Jin-hai, HUANG ; Shi-ming, CHENG ; Yi-fan, FENG ; Qin-mei, WANG
Chinese Journal of Experimental Ophthalmology 2013;(6):572-577
Background Sirius system,a new Scheimpflug camera combined with Placido topography,improved the capability of imaging the anterior eye segment significantly.However,the study of assessing the repeatability and agreement between Sirius and Pentacam is still lack up to now.Objective This study was to evaluate the repeatability and agreement of the anterior ocular segment measuring parameters by Sirius and Pentacam in myopia received laser in situ keratomileusis (LASIK).Methods Thirty-five myopic eyes of 35 patients received LASIK were included in School of Optometry and Ophthalmology Eye Hospital from 2010 May through 2010 July.Corneal power flat keratometry (Kf),step keratometry (Ks),mean keratometry (Km),thinnest corneal thickness(TCT),the location of TCT,anterior chamber depth (ACD) and anterior chamber volume (ACV) were measured by Sirius and Pentacam in all the eyes,respectively.The repeatability of the measuring results were evaluated using intraclass correlation coefficients (ICC) and Cronbach's coefficient alpha (CoA),and the agreement of measuring parameters between Sirius and Pentacam was analyzed using Bland-Altman plot.Results Both Sirius and Pentacam demonstrated high intraobserver repeatability,with all ICC and CoA more than 0.90.No significant differences were found in Kf values and Ks values between the two methods (t =-1.533,-1.750,P>0.05).Km value was (39.14 ± 1.95) D by Sirius measurement,which was sígnificantly higher than (39.05 ± 1.91) D by Pentacam measurement (t =3.572,P =0.001).The TCT was (457.6 ± 40.9) μm by Sirius method,showing a significant reduce in comparison with (465.4±37.5) μm of Pentacam method (t =-6.689,P<0.001).A positive correlation was seen in the TCT between the two methods (r=0.988,P<0.001).The Bland-Alrman plots showed the 95% CI-21 μm to 6 pm in the TCT value between the two devices.Pairwise comparison of the location of TCT measurements showed significant differences between the two devices (t =-4.132,-5.696,P<0.001),with a good correlation (r=0.751,0.775) and the 95% CI (-0.36-0.17 mm,-0.35-0.12 mm).A very good agreement was seen in ACD between the two devices (-0.02-0.12 mm),but the agreement result was not very well in the ACV between the two devices with the 95% CI (-27.70-6.20 mm3).Conclusions Sirius and Pentacam measurements for anterior ocular segment parameters have a very good repeatability in post-LASIK eyes.In addition,good agreement results are exhibited in corneal power,TCT and ACD between Sirius and Pentacam with an acceptable maximal different value between them.Sirius and Pentacam can be used interchangeably in clinical examination.However,the two devices can not interchangeably for ACV measurement and TCT location.
8.Determination of o-methylflavinantine in a Tibetan medicine Meconopsis quintuplinervia by HPLC.
Xia SHI ; Fang CHENG ; Mei GUO ; Jing SHAO
China Journal of Chinese Materia Medica 2011;36(23):3290-3292
OBJECTIVETo develop an HPLC method for the determination of a Tibetan medicine Meconopsis quintuplinervia.
METHODA Hypersil-Keystone-C18 column (4.6 mm x 250 mm, 5 microm) was used with the isocratic elution of acetonitrile and 0.012% glacial acetic acid. The flow rate was 1.0 mL x min(-1), and the detection wavelength was set at 237 nm.
RESULTThe linear range of 0-methylflavinantine was 0.2-2.4 microg (r = 0.999 7). The average recovery was 96.26%.
CONCLUSIONThe developed method was reliable, and can be used for the quality control of M. quintuplinervia Regel.
Chromatography, High Pressure Liquid ; Drugs, Chinese Herbal ; analysis ; chemistry ; Morphinans ; analysis ; Papaveraceae ; chemistry
9.Therapeutic bloodletting at Jing-well points combine hypothermia attenuated acute cerebral edema after traumatic brain injury in rats.
Xiao-mei MIAO ; Shi-xiang CHENG ; Zhen YANG ; Sai ZHANG ; Wan-jun HAN ; Yue TU ; Hong-tao SUN
Chinese Journal of Applied Physiology 2015;31(3):249-253
OBJECTIVETo investigate the influence of therapeutic bloodletting at Jing-well points and hypothermia on acute cerebral edema after traumatic brain injury (TBI) in rats.
METHODSSeventy-five SD rats were randomly divided into sham-operation group (Sham), TBI group (TBI), bloodletting group (BL), mild-induced hypothermia group (MIH), and bloodletting plus MIH group (BL + MIH) (n = 15). The model of TBI was established by electric controlled cortical impactor (eCCI). The rats of BL group were bloodletting at Jing-well points immediately after injury, twice daily. While the MIH group was settled on a hypothermia blanket promptly after TBI for 6 hours, so that the temperature dropped to 32 degrees. Each of measurement was performed after 48 hours. Magnetic resonance imaging (MRI) was used to evaluate the dynamic impairment of cerebral edema after TBI (n = 3). In addition, mNSS score, measurements of wet and dry brain weight, and Evans Blue assay were performed to investigate the neurologic deficit, cerebral water content (n = 8), and blood-brain barrier permeability (BBB), (n = 4), respectively.
RESULTSMRI analysis showed that the cerebral edema, hematoma and midline shifting of rats in TBI group was more serious than other treatment group. Meanwhile compared with TBI group, the mNSS scores of every treatment group were meaningfully lower (all P < 0.05). Furthermore, treatment with BL+ MIH group was superior to the separated BL and MIH group (all P < 0.01). In addition, brain water content of each intervention group reduced to varying degrees (all P < 0.05), especially that of MIH group and BL + MIH group (P <0.01). BBB permeability of each treatment group was also significantly improved (all P < 0.01), and the improvement in MIH group and BL + MIH group was much better than the BL alone group (P < 0.05, P < 0.01).
CONCLUSIONOur major finding is that bloodletting at Jing-well points and MIH can reduce cerebral edema and BBB dysfunction and exert neuroprotective effects after TBI. The results suggest that the combination of BL and MIH is more effective than other treatment being used alone.
Animals ; Blood-Brain Barrier ; Bloodletting ; Brain ; pathology ; Brain Edema ; prevention & control ; Brain Injuries ; therapy ; Hypothermia, Induced ; Rats ; Rats, Sprague-Dawley
10.Experimental Study of Adrenomedullin in Autoimmune Myocarditis Induced by Immunization of Mice with Lactobacillus Casei Cell Wall Element
ji-wei, ZHANG ; hong-wei, WANG ; mei-zhen, NIU ; hong, SHI ; qing-jun, LIU ; pei-xuan, CHENG ; ya -li, LIU
Journal of Applied Clinical Pediatrics 2004;0(11):-
Objective To study adrenomedullin (AM) mRNA and protein expression level in myocardium of autoimmune myocarditis animal models induced by immunization of mice with lactobacillus casei cell wall element(LCWE). Methods Forty-five Balb/c male mice were randomly divided into experimental group (n = 30) and control group (n = 15), which were intraperitoneally injected with LCWE and phosphate buffered solution(PBS) at day 0,3,5 and 10,respectively. Sera and myocardium samples were gained 14,21 and 28 days after the first immunization. AM expression levels were determined by semiquantitative reverse transcriptase-polymerase chain reaction(RT- PCR) and immunchistochemistry,and mycardial histopathological lesions were observed. The anti- myosin antibodies in different stages were examined by an ELISA. Results There were myocardial necrosis or inflammatory infiltration in the experimental group, but myocardial lesions were not found in the control group. Anti - myosin antibodies were detected in sera of experimental mice,but not in control group. Immunchistochemistry findings demonstrated that AM expression level was higher in the experimental group than in the control group( P