5.Application and advance of finite element method in spinal biomechanics
zheng-yu, WANG ; zu-de, LIU ; cheng-tao, WANG
Journal of Shanghai Jiaotong University(Medical Science) 2006;0(09):-
As a novel research tool in the field of the spinal biomechanics, the finite element method (FEM) complements and verifies the traditional research methods, which has been attached increasingly greater importance. In this paper, we briefly introduce the achievement made in the field of spinal biomechanics by FEM in the past decade, summarize the physiological and pathological behaviors of various spinal anatomical parts described by FEM, and present the basic view of using FEM to optimize the surgery instrument design.
6.Research advance in effectiveness of bracing for adolescent idiopathic scoliosis
zheng-yu, WANG ; zu-de, LIU ; cheng-tao, WANG
Journal of Shanghai Jiaotong University(Medical Science) 2006;0(01):-
The role of bracing for adolescent idiopathic scoliosis,which came into application in 1960's,has long been controversial.There are various brace instrument with different reported effectiveness.In this paper,we summarize the research findings and main views in the effectiveness of bracing for adolescent idiopathic scoliosis in the past ten years,and explore the possible causes leading to the different results.Besides,we are trying to point out the research trend,in hope of drawing a scientific conclusion on the effectiveness of bracing treatment in the near future.
9.Comparison between Gamma nail and DHS/Richard in treatment of proximal femoral fracture: a meta analysis
Xin TANG ; Cheng LDE ; Fusheng WANG ; Ming LU ;
Chinese Journal of Orthopaedic Trauma 2004;0(05):-
Objective To asses the effects of Gamma nail and DHS/Richard (dynamic hip screw) in the treatment of proximal femoral fractures. Methods A meta analysis of all the relevant randomized controlled trials (RCTs) was performed. We included randomized and quasi randomized controlled trials in patients with proximal femoral fracture to compare Gamma nail and DHS/Richard. Results First we identified 88 papers on comparison of Gamma nail and DHS/Richard in the treatment of proximal femoral fractures published from 1969 to 2003. 7 trials involving 1256 patients were identified as meeting all the eligibility criteria. 3 investigators independently graded study quality and abstracted relevant data, including information on mortality rates, wound infection, function, revision in patients with a proximal femoral fracture. 4 trials, which included a total of 621 patients, provided detailed information on mortality rates over the first 6 postoperative months. We found there was no significant difference in the relative risk of death in the first 6 months postoperative between treatments of Gamma nail and those of compression hip screw (relative risk 1.17;P=0.51). 6 trials that included a total of 1083 patients provided data on operative complications. The risk of operative complications from Gamma nail fixation appeared to be higher than that from compression screw and side plate fixation but not higher than that from compression hip screw (relative risk 1.41; P=0.02). We also found an obvious increase in the relative risk of fracture of femoral shaft between Gamma nail and compression hip screw (relative risk 6.99; P=0.00). Patients treated with Gamma nail had a higher rate of revision compared with those with compression hip screw, but there was no significant difference between the two groups (relative risk 1.85; P=0.20). In addition, wound infection, operative blood loss and functional recovery were similar between the tow groups(relative risk 0.98 for wound infection and 1.02 for function). Operating time for Gamma nail patients was significantly less than that for DHS/Richard ones (P
10.Surgical treatment for displaced clavicle fracture combined with coracoid process: 9 cases report.
Bao-bing YAO ; Liang ZHA ; Cheng-guo YIN ; Tong-li WANG ; Wen-de WANG ; Ye-ben WANG ; De-fu WU
China Journal of Orthopaedics and Traumatology 2014;27(12):1043-1046
OBJECTIVETo explore clinical effects of internal fixation in treating displaced clavicle fracture combined with coracoid process.
METHODSFrom January 2005 to July 2012, 9 patients with displaced clavicle fracture combined with coracoid process were treated by internal fixation. Among them, there were 6 males and 3 females with an average age of 40.1 (ranged from 20 to 57) years old. According to Eyres classification: 3 cases were type II B, 1 case was type II A, 3 cases were type III B, and 2 cases were type V A. All patients had history of injury, and diagnosed as coracoid fracture X-ray and CT before operation. Herscovici criteria was used to evaluate function of shoulders joint after operation.
RESULTSSeven of 9 patients were followed up from 6 to 18 (averaged 11) months. The incisions were healed at stage I, coracoid process obtained bony healing, and reduction of acromioclavicular joint well. According to Herscovici criteria, 6 patients got excellent results and 1 in good.
CONCLUSIONInternal fixation for the treatment of displaced clavicle fracture combined with coracoid process could restore physiological anatomical position of coracoid process, and benefit for recovery of limb function.
Adult ; Clavicle ; injuries ; Female ; Fracture Fixation, Internal ; methods ; Fractures, Bone ; surgery ; Humans ; Male ; Middle Aged ; Recovery of Function ; Scapula ; injuries ; Shoulder Joint ; injuries