1.Simultaneous Determination of Andrographlide and Dehydroandrographolide in Ganmaoqing Tablet by HPLC
Huiying XU ; Baihong XU ; Haoan CHEN ; Yang LI ; Danting SHANG
China Pharmacy 2016;27(12):1699-1701
OBJECTIVE:To establish a method for simultaneous determination of andrographlide and dehydroandrographolide in Ganmaoqing tablet. METHODS:HPLC was performed on the column of Thermo BDS C18 with mobile phase of mathanol-water at a flow rate of 1.0 ml/min,detection wavelength was 225 nm for andrographlide and 254 nm for dehydroandrographolide,col-umn temperature was 30 ℃,and injection volume was 10 μl. RESULTS:The linear range was 2.25-45.00 μg/ml for andrographlide (r=0.9998) and 1.00-20.00 μg/ml for dehydroandrographolid(r=0.9990);RSDs of precision,stability and reproducibility tests were no more than 0.8%;average recoveries were 96.96%-99.80%(n=9) and 96.79%-100.65%(n=9). CONCLUSIONS:The method is simple,accurate and reliable,and can be used for the quality control of andrographlide and dehydroandrographolide in Ganmaoqing tablet.
2.Factors affecting the treatment of hypertension in Elderly in the community of Yanji Area of Shanghai
Yichen WANG ; Jinglong ZHANG ; Qian CHEN ; Hanji SHANG ; Yanling XU
Chinese Journal of Hypertension 2001;9(2):167-168
Objective To evaluate the factors affecting the treatment of old persons diagnosed hypertension. Method A sample of 55566 persons from the community of Yanji area of Shanghai was recruited. Results Among the 19295 persons over sixty there are 5842 patients with hypertension, the morbidity was 30.3%. Among the 36271 persons aged fifteen to fifty-nine there are 3536 patients with hypertension, the morbidity is 9.7%. The ratio of non-treatment in the old age group is 3.1% and in younger group is 8.8%. However,the compliance to the treatment was better in the younger than in old group(73.7% vs 56.2%). The age,hypertension grade and sex were all accounted for the differences in the regularity of the hypertension treatment. Conclusion Further effort on the education of non-old hypertensive patients is essential to decrease the damage from hypertension.
3.Research on serum TSGF levels in healthy people and cancer patients in Guangzhou area
Wen SHI ; Chenyu SHANG ; Lin CHEN ; Li LIN ; Jianhua XU
International Journal of Laboratory Medicine 2014;(19):2648-2649
Objective To investigate the results of tumor specific growth factor(TSGF) levels in in healthy people and cancer patients in Guangzhou areas .Methods The serum TSGF levels of 6 615 health check-up receivers and 287 patients with cancer in the hospital from July 2012 to June 2013 were detected .Results In health check-up receivers ,the level and positive rate of TSGF were higher in >40-50 age women .The level and positive rate of TSGF in men were increased with age .The levels of TSGF in pa-tients with lung cancer ,liver cancer and digestive system tumor were higher than that in health check-up receivers(P<0 .01) ,but there has no statistically difference between genital system cancer patients and healthy check-up receivers(P>0 .05) .Conclusion Performing TSGF test in health examination is great significance to the early diagnosis of malignant tumors .The reference value range of TSGF should be set according to different gender and age .
5.Cleaning Efficacy of Automatic Cleaning Machines Evaluation and Impact Factors
Ling SHANG ; Hailing XU ; Hongmei WANG ; Xinhua WANG ; Meiying CHEN
Chinese Journal of Nosocomiology 2005;0(11):-
OBJECTIVE To evaluate the cleaning efficacy of the automatic cleaning machine and the risk factors to ensure the effect of disinfection and sterilization. METHODS Cleaning efficacy of the automatic cleaning machines was detected by STF cleaning test card.It was put in the first cabin of every automatic cleaning machine.And it was also tested for these factors in determining cleaning qualities such as enzyme concentration,water temperature and pieces of instruments washed. RESULTS The cleaning efficacy of the automatic cleaning machines was 98.9% in the continuous two years.The qualified rate was 98.6% for surgical instruments,99.4% for all instrument in clinical sections. CONCLUSIONS The machine is suitable for the cleaning of surgical instruments.It also raises working efficiency,cutting down the cost of repairs and maintenance,reducing the chances of injury and infections in nurses who performed manual cleaning precedures.The procedures of the STF cleaning test card in detecting the cleaning efficacy is simpler,safer,and suitable for clinical applications.
8.The characteristics of enzyme kinetics of CTX-M-14 type extended-spectrum β-lactamase with Pro167 residue substitution
Rong XU ; Zhongbo SHANG ; Junwei HUANG ; Dongqing HAN ; Zhen WANG ; Yongliang LOU ; Xiushu CHEN
Chinese Journal of Microbiology and Immunology 2011;(3):250-254
Objective To analyze and evaluate the characteristics of enzyme kinetics of CTX-M-14 type extended-spectrum β-lactamase(ESBL) with Pro167 residue substitution. Methods By molecular cloning and PCR techniques, CTX-M-14 gene was directionally cloned into plasmid pET28a( + ) from a clinical E. coli isolate and formed an expression vector to transform competent E. coli BL21 (DE3 ). Prol67 residue substitutions of P167G, P167Q, P167S and P167T were introduced to CTX-M-14 by site-directed muta-genesis based on overlap extension PCR with the former recombinant plasmid as PCR template, respectively.The wild-type CTX-M-14, recombinant CTX-M-14 protein and its variants were expressed and purified, then their steady-state kinetic parameters (Kcat, Km and Kcat/Km ) against β-lactam antibiotics were determined.Results The kinetic parameters of wild-type and recombinant CTX-M-14 had no statistically significant differences (P>0.1). The 1/Km, Kcat and Kcat/Km values of P167S variant against ceftazidime were 16-fold, 2.87-fold and 43.6-fold higher than those of recombinant CTX-M-14, respectively, and the Kcat/Km value of P167S variant against penicillin, ampicillin, cefazolin, cefuroxime, ceftriaxone, cefotaxime decreased( < 0.05). Compared with the kinetic parameters of recombinant CTX-M-14, the kinetic parameters of P167T variant against ceftazidime had no significant change, but the Kcat values of P167Q and P167G variants decreased dramatically(P<0.01). Conclusion There was no difference between the enzyme activities of wild-type and recombinant CTX-M-14. P167S variant could not only promote the enzyme affinity of CTX-M-14 to ceftazidime but also improve the conversion rate of enzyme-substrate complex in the ceftazidime hydrolysis. The comparison of the kinetic parameters of CTX-M-14 and its variants with Pro167 residue substitution showed that the increased activity of CTX-M ESBL variants against ceftazidime could not be simply explained with the enlarged cavity in active site that may be caused by the replacement of Pro167 residue by smaller amino acids.
9.Improvement of elbow joint lateral position for the display of radial head in actual application
Lei XUE ; Junwei JI ; Xu SHANG ; Feng CAO ; Lei CHEN ; Weiwei QI
Journal of Practical Radiology 2015;(10):1661-1663
Objective To improve lesion detection of the radial head with adjusted elbow joint lateral position on X-ray.Methods (1)20 subjects underwent elbow joint CT three-dimensional reconstruction (average intensity projection),which was as X-ray radio-graphy image.The tilt angle of the humerus and the projection direction for fully display of the radial head in projection images and the tilt angle of the humerus against detector in X-ray radiography were measured.(2)20 subjects (patients and volunteers)with el-bow joint disease underwent routine and improved elbow joint lateral position were enrolled.And assessed the bare blocking rate of the radial head articular surface of the two positions.Results (1)The angle between the the humerus and the direction of projection were 49°-60°and 30°-41°in CT and X-ray,respectively.The average angle was (35.5±1)°.(2).The blocking rate and bare bloc-king rate of the radial head articular surface in routine elbow joint lateral position were 71.6%-100% and 0%-28.4%,respective-ly.The average rate of bare blocking was 14.2%.Fracture 13 cases and 5 cases of suspected fractures.The blocking rate and bare blocking rate of the radial head articular surface in improved elbow joint lateral position were 4.8%-25% and 75%-95.2%,re-spectively.The average rate of bare blocking was 85.1%.Fracture 1 7 cases and 1 case of suspectet fractures.Conclusion The im-proved elbow joint lateral position of X-ray can display the radial head articular surface better than the routine position.
10.To study the feasibility of defining the internal gross tumor volume for hepatocellular carcinoma applying the enhanced 4DCT images obtained by deformable registration technology
Hua XU ; Guanzhong GONG ; Jinhu CHEN ; Dongping SHANG ; Tonghai LIU ; Jian ZHU ; Jie LU
Chinese Journal of Radiation Oncology 2015;24(3):331-334
Objective To study the feasibility of defining the internal gross tumor volume (IGTV) of hepatocellular carcinoma applying the enhanced four-dimensional computed tomography (4DCT) images with deformable registration technology.Methods Ten HCC patients who accepted radiation therapy were selected in this study.The 4DCT in free breathing,non-enhanced 3DCT and arterial phase enhanced 3DCT in end inspiration breath holding associated with active breathing coordinator were acquired sequentially.4DCT were sorted into ten series CT images according to breath phase,and named CT00,CT10..…CT90.Gross tumor volume (GTV) were contoured on different CT series and the IGTV1 was merged by ten phases GTVs of 4DCT.The GTV of enhanced 3DCT was registered to different CT series of 4DCT and the IGTVDR was obtained by merging the GTVs after deformable registration.The target volumes differences were compared by paired t-test.Results The edge of tumor was difficult to define on 4DCT and non-enhanced 3DCT images.The enhanced 3DCT image showed clearer tumor edge,and the GTV increased by mean 37.99% compared to GTV on 4DCT different series images and non-enhanced 3DCT image (P =0.002).The GTV after deformable registration on 4DCT different phase images increased by mean 36.34% (P =0.011),which were similar to GTV on enhanced 3DCT image (P =0.632).The IGTVDR increased by 19.91% (P =0.017),compared to IGTV1.Conclusions The contrast-enhanced 4DCT image which was obtained by combining enhanced 3DCT and 4DCT images with deformable registration technology could raise the position precision of the HCC IGTV effectively.