2.Progress in the research on commonly used anti-cancer traditional Chinese medicine capsules combined with chemotherapy on middle-advanced stage lung cancer.
Li BIAN ; Si-sheng TIAN ; Ya-lin CHEN
Chinese Journal of Integrated Traditional and Western Medicine 2009;29(3):279-282
Antineoplastic Combined Chemotherapy Protocols
;
therapeutic use
;
Capsules
;
Carcinoma, Non-Small-Cell Lung
;
drug therapy
;
Drug Therapy, Combination
;
Drugs, Chinese Herbal
;
therapeutic use
;
Humans
;
Integrative Medicine
;
Lung Neoplasms
;
drug therapy
;
Phytotherapy
;
Small Cell Lung Carcinoma
;
drug therapy
3.Normal macular thickness in healthy Asian yellow race children
Si CHEN ; Lin XIAO ; Xiaofang REN ; Enzong JIN
Chinese Journal of Medical Science Research Management 2013;26(4):281-284
Objective To study the normal macular thickness in children provide reference for the diagnosis of macular thickness abnormity in teenagers.Methods Databases including Wanfang,Pubmed and some others were searched for studies on macular thickness in Asian children.Data of macular thickness were extracted and were merged into only one by formulae.Results 12 studies were enrolled.The mean foveal minimum and central macular thickness were 143.89±17.32μm(n=2062 eyes) and 181.60±17.93μm(n=1974 eyes),respectively.The eight areas of inner circle (1~3mm diameter) and the outer circle (3~6mm diameter) macular thickness were also calculated.The central macular area seemed thicker in pre-school children than school children.Conclusion Chidren's macular thickness have different characteristic from adults',so it is important to take age,refraction,axial length,race and sex into account before making an abnormal macular thickness diagnosis.Meanwhile,a large sample of population-based cross-sectional study in children is necessary for a more effective standard.
4.Clinical exploration based on cost analysis: costs among different screening methods for myopia in school-aged children
Si CHEN ; Enzong JIN ; Xiaofang REN ; Jinglei YAO ; Lin XIAO
Chinese Journal of Medical Science Research Management 2013;26(6):427-429
To explore an easily executive and conveniently generalized method with effectiveness and low costing for myopia screening at the early stage.Research was performed to testify the reasonability of using axial length/corneal radius (AL/CR) for myopia screening in children by comparing the cost between AL/CR plus vision acuity (VA) and simple VA examination.Chinese school-aged children in Yangfang school district,Beijing (n=1427,aged 6~12 years old) were randomly grouped for either pure VA examination or for VA plus AL/CR examination.Those suspicious myopic children were informed for further refractive examination.Finally,the cost from screening to definite diagnosis of refractive error was calculated.Generally,compared with VA examination,the total cost was reduced by 15.12% and by 12.34%,respectively,in the elder group using VA plus AL/CR examination.VA plus AL/CR examination is an economical and reasonable method for screening suspicious myopia in Chinese school-aged children compared with pure VA examination.
5.Mechanism of combined treatment with Shenkangling Decoction and prednisone in rats with adriamycin-induced nephropathy.
Qing LIN ; Jian ZHENG ; Si AI ; Lixing LIN ; Yuxin CHEN ; Fang WANG ; Ling ZHU
Journal of Integrative Medicine 2009;7(7):661-6
To study the mechanism of Shenkangling (SKL), a compound traditional Chinese herbal medicine, combined with prednisone in treating adriamycin-induced nephropathy in rats.
6.Effects of gender on incidence of intraventricular hemorrhage in very low and extremely low birth weight infants
Si CHEN ; Su LIN ; Hao ZHANG ; Qingqing JIE ; Kun SHANG ; Li WANG ; Zhenlang LIN
Chinese Journal of Perinatal Medicine 2014;17(5):317-322
Objective To examine the relationship between gender and intraventricular hemorrhage (IVH) in very low birth weight infants (VLBWI) and extremely low birth weight infants (ELBWI).Methods From January 1,1999 to December 31,2012,data on VLBWI and ELBWI,who were admitted to the neonatal intensive care unit of Yuying Children's Hospital within 14 d after birth,were retrospectively collected.The Chi-square test and t test were used to compare neonatal outcomes between male and female infants.The Logistic model was used to analyze the risk factors for IVH.Results A total of 1 008 cases were enrolled,including 615 males and 393 females,895 VLBWI and 113 ELBWI.The incidence of IVH was 15.1% (152/1 008) and the incidence of severe IVH was 8.4% (85/1 008).Compared with females,males had a higher total incidence of IVH [17.2% (106/615) vs 11.7% (46/393),x2=5.728,P<0.05] and severe IVH [9.8% (60/615) vs 6.4% (25/393),x2=3.896,P<0.05].These differences were also seen in VLBWI with a birth weight of 1 250 to 1 499 g [IVH:13.7% (47/344) vs 7.8% (17/217),x2=4.473,P=0.034; severe IVH:7.6% (26/344) vs 2.8% (6/217),x2=5.684,P=0.017].Logistic regression analysis showed that the risk factors for IVH were as follows:gestational age <28 weeks (aOR=2.012,95%CI:1.288-3.143,P<0.05),neonatal respiratory distress syndrome (aOR=l.584,95%CI:1.007-2.492,P<0.05),invasive mechanical ventilation (aOR=2.743,95%CI:1.826-4.121,P<0.05),electrolyte disturbance (aOR=2.128,95%CI:1.092-4.149,P<0.05) and periventricular leukomalacia (aOR=2.901,95%CI:1.312-6.416,P<0.05),but not male sex (aOR=1.351,95%CI:0.917-1.991,P=0.128).The risk factors for severe IVH were gestational age <28 weeks (aOR=2.200,95%CI:1.305-3.708,P<0.05),invasive mechanical ventilation (aOR=4.714,95%CI:2.809-7.911,P<0.05) and electrolyte disturbance (aOR=2.232,95%CI:1.047 4.759,P<0.05),but not male sex (aOR=1.361,95%CI:0.823 2.252,P=0.247).Conclusions Male VLBWI and ELBWI have a higher incidence of IVH and severe IVH,but male sex is not a risk factor for IVH or severe IVH.
7.Repeatability and reproducibility of retinal straylight measurement using C-Quant compensation comparison method
Jin-hai, HUANG ; Shi-shi, LIN ; Qin-mei, WANG ; Bo, ZHENG ; Si-si, CHEN ; Rong-rong, GAO
Chinese Journal of Experimental Ophthalmology 2012;30(2):160-163
BackgroundIn an ideal eye there would be no light scattering at all,but the eye media is not optically ideal.Intraocular straylight causes a veil of light and reduction in the contrast of the retinal image and thus decrease the quality of vision.ObjectiveThe present study was to investigate the repeatability and reproducibility of C-Quant straylight meter( Oculus,Germany)in measuring retinal straylight of myopia and post-laser in situ keratomileusis(LASIK) corneas.MethodsThis is a prospective research.The consecutive 35 eyes of 21 myopic patients and 34 eyes of 22 patients who received LASIK were included in this trail.Retinal straylight was measured for 7 times at a period of time and analyzed quantificational to evaluate the repeatability of measurement.Thirty-eight eyes of 19 patients were measured again at 3-7 days for 3 times at a period of time to assess the reproducibility of C-Quant straylight meter.The mean standard difference (SD) and coefficient of variation (CV) were used as the credibility evaluation.This clinical study complied with Helsinki Declaration and the informed consent was obtained prior to the medical procedure.ResultsThe straylight Log(s) of 7 times measurement were all less than 0.95.The mean Log(s) were 0.92±0.12 and 0.93±0.17 respectively in myopia group and post-LASIK group,without statistically significant differences among 7 times measurement( F=0.335,P=0.812;F=1.000,P=0.409).The mean SD for the 7 times measurement was 0.07 Log units.SD and CV increased with the number of measurements.The differences of mean SD and CV between 3 times result and 6 times result were significant different (t =-2.080,P =0.045;t =-2.190,P =0.035 ).No difference was found between different time periods( t =-0.531,P=0.598 ).The difference of the results between two measurements from the same patient was 0.013.ConclusionsC-Quant is a noncontact,noninvade,rapid and convenient method for the measurement of straylight in myopia and post-LASIK eyes due to the high repeatability and reproducibility.
8.Effectiveness of plastic wrap in prevention of hypothermia in very low birth weight infants
Yanli LIU ; Wei ZHOU ; Zhenhai TANG ; Si CHEN ; Qi WANG ; Nengli WANG ; Zhenlang LIN
Chinese Journal of Perinatal Medicine 2014;17(4):244-248
Objective To evaluate the effectiveness of occlusive wrapping with plastic film in the delivery room to prevent heat loss and reduce the occurrence of hypothermia on admission to the Neonatal Intensive Care Unit (NICU) in very low birth weight infants.Methods A total of 209 very low birth weight infants (birth weight<1 500 g and gestational age<33 weeks),born in the Second Hospital of Wenzhou Medical University (Yuying Children's Hospital) and admitted to the NICU immediately after birth from June 1,2009 to December 1,2010,were randomized to the wrap group or non-wrap group.Infants randomized to the wrap group were dried and then wrapped with polyethylene film up to their necks immediately after delivery.They were then covered with warmed blankets and transported to the NICU by the neonatal team.The non-wrap group received routine care in the delivery room following the guidelines of the Neonatal Resuscitation Program.The t test and Chi-square test were used for statistical analysis.Results The mean rectal temperature on admission to the NICU was significantly higher in infants of wrap group compared with those of non-wrap group [(36.1 ± 0.8) ℃ vs (35.5 ± 1.0) ℃,t=4.707,P<0.01],and the incidence of hypothermia was 41.0% (43/105) in the wrap group which was lower than that in the non-wrap group (66.3%,69/104) (x2=13.547,P<0.01).In infants <29 weeks of gestation,the mean rectal temperature on admission to the NICU was higher in the wrap group than in the non-wrap group [(36.1 ± 0.8) ℃ vs (35.4 ± 1.1) ℃,t=3.051,P<0.01].In infants ≥ 29 weeks of gestation,the mean rectal temperature on admission to the NICU was higher in the wrap group than in the non wrap group [(36.0±0.9) ℃ vs (35.5±0.9) ℃,t=3.698,P<0.01].The arterial blood gas base excess in the wrap group and non-wrap group was-(2.9±2.7) mmol/L and-(5.0±4.2) mmol/L,respectively (t=4.473,P<0.01).The rate of endotracheal intubation was 20.0% (21/105) in the wrap group and 27.9% (29/104) in the non-wrap group,(x2=1.785,P=0.182).The duration of hospitalization was (49.2± 10.7) d in the wrap group and (45.8±9.1) d in the non-wrap group,and the difference was not statistically significant (t=1.152,P=0.251).Conclusions Wrapping very low birth weight infants with plastic film in the delivery room can reduce the occurrence of hypothermia.
9.Rat bone marrow mesenchymal stem cells induce hepatic stellate cells apoptosis in vivo
Nan LIN ; Shujie XIE ; Weidong PAN ; Kunpeng HU ; Si CHEN ; Yutian CHONG ; Peng XIANG ; Ruiyun XU
Chinese Journal of Tissue Engineering Research 2010;14(10):1769-1774
BACKGROUND:It is reported that bone marrow mesenchymal stem cell(BMSC)transplantation might be a promising treatment for liver fibrosis.But the mechanism is still unclear.OBJECTIVE:To observe the hepatic stellate cells apoptosis induced by BMSC transplantation,and to study the mechanism of BMSC in treating hepatic fibrosis in vivo.METHODS:CCl_4 subcutaneous injection was performed to induce rat liver fibrosis.After 8 weeks of CCU injection,20 rats which underwent successful model establishment were randomly divided into experimental group and control group,10 in each group.The experimental group received MSC transplantation via tail vein injection,and the control group were given DMEM instead.The rats were killed and the livers were harvested at three time point,the day of MSC transplantation,3 days after transplantation,and 7 days after transplantation.The hydroxyproline content was detected by HE and Masson staining,and the expression changes of α-smooth muscle actin(α-SMA)proteins were determined using immunohistochemistry.The apoptosis of hepatic stellate cells were determined by α-SMA and TUNEL(terminal dUTP nick-end labeling)dual-staining.RESULTS AND CONCLUSION:After 8 weeks of CCU injection,the hydroxyproline content increased and histology indicated progress of liver fibrosis.At 7 days after MSC transplantation,the hydroxyproline in the liver was decreased,and the liver fibrosis was alleviated in the experimental group but aggravated in the control group.Immunohistochemistry indicated that α-SMA positive cells were increased at 8 weeks after CCU injection.At day 7 after transplantation,α-SMA positive cells in the experimental group were significantly less than control group(P < 0.05).At 3 days after transplantation,the hepatic stellate cells apoptosis in the experimental group was significantly aggravated compared with control group(P < 0.05).This suggested that MSC transplant was an effective treatment for liver fibrosis.MSC inducing hepatic stellate cells apoptosis may be one of the mechanisms.
10.Clinical Observation of Automatic Ventricular Capture Management Confirmed by Paced Depolarization Integral Evoked Response Detection
Hailong SI ; Qin QIN ; Gang CHEN ; Yaru LU ; Lu KOU ; Wenhua LIN ; Ziwen REN ; Bingrang ZHAO
Chinese Circulation Journal 2016;31(4):358-361
Objective: To observe the automatic ventricular capture management (VCM) conifrmed by paced depolarization integral (PDI) evoked response detection via the follow-up study in patients with Zephyr5826 pacemaker implantation. Methods: A total of 102 relevant patients were enrolled. In order to conduct PDI calculation, pacemakers were set by bipolar sensing and bipolar pacing at immediately after implantation. VCM functions were observed at 1 day, 7 days and 1 month, 3, 6, 12 months after implantation, the ventricular threshold by VCM test and manual test were compared. The symptoms of pectoralis major stimulus, diaphragm stimulus and palpitation were observed in all follow-up patients. Results: There was 1 patient died by MI at 1 month after Zephyr5826 pacemaker implantation, the rest 101 patients were followed-up for 12 months. VCM function was successfully turned-on at immediately after implantation in all patients, no pectoralis major stimulus and diaphragm stimulus occurred. VCM function was turned-off in 6/101 (5.9%) patients at 7 days after implantation due to intolerable palpitation caused by daily automatic VCM, instead they received manual test at follow-up visit. The coincidence rate of ventricular thresholds between VCM test and manual test were 100%. Ventricular pacing output voltage by VCM was (0.99 ± 0.48) V,n=608. Compared with regular pacing output voltage (2.5V, 0.4ms), VCM function may save 84% of energy consumption; compared to high pacing output voltage (3.5V, 0.4ms), VCM may save 92%. Loss of ventricular capture and poor sensation were not found by ECG and 24 h dynamic monitoring. Conclusion: Zephyr5826 pacemaker may conduct bipolar pacing and scanning with VCM function, it can be effectively and safely operated by low energy output. A few patients may not use VCM function due to intolerable palpitation.