1.Evaluation of coronary collateral circulation with intracoronary Doppler ultrasound after acute occlusion in pigs
Wu XU ; Chaoqun ZHANG ; Jiandong WU
Chinese Journal of Interventional Cardiology 2003;0(05):-
Objective To evaluate the formation of coronary collateral circulation with intracoronary Doppler ultrasound in pigs after acute occlusion and the influence of nitroglycerin and phentolamine on it.Methods The blood flow spectrun was detected in 14 pigs using intracoronary Doppler ultrasound before and after acute occlusion of the left circumflex artery (LCX) and its response to nitroglycerin and phentolamine.The average peak velocity (APV) and the diastolic systolic velocity ratio (DSVR) were recorded. Results The APV of the LCX decreased significantly at 10 min after acute occlusion (0.97?1.05 vs 25.78?4.36 cm/s,P0.05). Conclusion Intracoronary Doppler ultrasound can be used to evaluate coronary collateral circulation. The formation collateral circulation was insufficient after acute occlusion of coronary artery in pigs and nitroglycerin or phentolamine can improve the blood flow.
2.Comparisom of different methods of determination of eosinophil cells
Yanyan XU ; Junqing WU ; Chaoqun LIU ; Ying HUANG
Chinese Journal of Primary Medicine and Pharmacy 2010;17(21):2903-2904
Objective To comparisom five methods of detection of eosinophil cells,in order to analyze the precision of the five methods.Methods The eosinophil cells of 100 patients were tested by using microscope、BC T5difft and flow cytometry are(0.249 ±0.112) × 109/L,(0.253 ±0.105) × 109/L,(0.252 ±0.103) × 109/L,(0.256 ±0.104) × 109/L and(0.259 ±0.101) × 109/L.There are no statistical differences(F = 1.225,P>0.10)among the five methods.Conclusion The results of the five methods are all accurate;the automatic analyzer method and the flow cytometry method are simple and repeatable,but the equipment and reagents are more expensive;the microscope direct counting method is more complicated and less repeatable.
3.Investigation and analysis on professional identity of nursing students with different educational backgrounds
Hongbo XU ; Ping ZHAO ; Chaoqun DONG ; Lianlian ZHU ; Lusha ZHOU
Chinese Journal of Practical Nursing 2013;(15):15-19
Objective To investigate and analyze the status quo of professional identity of nursing students with different educational backgrounds.Methods With stratified-cluster random sampling,635 students were surveyed using the nursing students' professional identity questionnaire.Results The total score of professional identity of junior college nursing students was significantly higher than that of undergraduate students.Junior college nursing students had a higher score in professional knowledge dimension than undergraduate and graduate students,while the score of nursing undergraduate students was higher than that of graduate students.Junior college nursing students had a higher score in professional will dimension than undergraduate and graduate students.Nursing graduate students had a higher score in professional expectation dimension than junior college and undergraduate students,while the score of undergraduate students was higher than that of junior college students.Whatever the educational background,professional skill and professional expectation were the top two dimensions,while professional knowledge and professional emotion were the last two dimensions.The difference was statistically significant between the answers of nursing students with different educational backgrounds to the following questions,such as which is the most probable factor affecting your learning enthusiasm,who has the greatest impact on your professional thought about nursing and which nursing field are you most willing to go in for.There was significant difference in professional identity score between different grades of junior college and undergraduate nursing students,while there is no significant grade difference in graduate students.Conclusions There were some differences of professional identity of nursing students with different educational backgrounds.Nursing educators should carry out the professional education according to the student's educational backgrounds.
4.Introduction of Spinal Cord Independence Measure Ⅲ
Chaoqun YE ; Tiansheng SUN ; Jianjun LI ; Hongjun ZHOU ; Shaoding xu
Chinese Journal of Rehabilitation Theory and Practice 2007;13(10):921-922
: Assessment of functional ability is main item of outcome measure in patients with spinal cord injury(SCI).The assessment methods include Barthel Index(BI),Modified Barthel Index(MBI),Functional Independence Measure(FIM),Spinal Cord Lesion Independence Measure(SCIM) and Walking Index for Spinal Cord Injury(WSCI).SCIM was specifically developed to measure functional ability for spinal cord lesion,which was modified for two times and verified in multicenter international study.The result of multicenter international study showed that SCIM is a reliable and useful quantitative representation of a specific construct of independence after SCI.This justifies the use of SCIM in clinical research,including cross-cultural trials.Meanwhile,further refinement is needed.
5.Some experience of field medical station equipment and materials management.
Shuang HE ; Chaoqun ZHANG ; Yonghe HU ; Longfu ZHOU ; Jian HE ; Kewei XU ; Ben XU
Chinese Journal of Medical Instrumentation 2013;37(6):454-456
The field medical station in military hospital plays an important role in the military logistic system. To better accomplish the duty of medical support mission, the problems of medical equipment and material store house management in the field medical station are discussed. Some targeted suggestions are introduced from daily management and the use of equipment respectively. It can be used as reference for other military hospitals to accomplish different medical support tasks.
Hospitals, Military
;
organization & administration
;
Military Medicine
;
instrumentation
6.Green Synthesis of Fluorescent Carbon Quantum Dots for Detection of Hg2+
Yue XU ; Chunjing TANG ; Hong HUANG ; Chaoqun SUN ; Yakun ZHANG ; Qunfeng YE ; Aijun WANG
Chinese Journal of Analytical Chemistry 2014;(9):1252-1258
Fluorescent carbon quantum dots ( CQDs) were synthesized by one-step hydrothermal treatment of apple juice. Experiments showed that Hg2+could quench the fluorescence of the CQDs with specificity. Based on this phenomenon, a selective and sensitive sensor was constructed for Hg2+ detection. In a NaH2 PO4-Na2HPO4 buffer solution (pH 7. 0), their fluorescence intensity showed good linear relationship with the concentrations of Hg2+ from 5 to 100 nmol/L and 1 to 50 μmol/L, respectively, with the detection limit of 2. 3 nmol/L (S/N=3). Its practical application was further demonstrated by the detection of Hg2+ in real water samples.
7.The value of Turbo inversion recovery magnitude (TIRM) magnetic resonance neurography for sacral plexus injury
Youlai ZHANG ; Chaoqun YANG ; Junjian JIANG ; Haopeng PANG ; Linjiang ZHOU ; Jiuzhou LU ; Lei XU
Chinese Journal of Microsurgery 2016;39(3):246-250
Objective To evaluate the capability of Turbo inversion recovery magnitude (TIRM) magnetic resonance neurography (MRN) in the diagnosie of sacral plexus injury by comparing MRN findings with surgical results.Methods Ten patients with sacral plexus injury confirmed surgically underwent conventional T1WI,T2WI,TIRM and coronal TIRM MRN before operations from June,2011 to December,2012.The MRI data and surgical data were analyzed retrospectively to observe nerve injury.Results The coronal TIRM MRN images displayed 93 trunks of sacral plexus,of which 37 were confirmed injury by operation.The MRI findings were as follows:6 trunks involved continuous nerves,but with thickening and blurred margin,as well as abnormal high signal intensity;22 trunks were continuous,but with distortion,stiffness and adhesion accompanied by heterogeneous signal intensity and structural disorder;3 trunks showed complete loss of continuity,absence of normal signal,accompanied by retraction;and 3 trunks involved formation of traumatic neurofibroma.The coincidence of injured nerve trunks diagnosed by MRN with surgical findings amounts to 81.08% (30/37).Conclusion MR with coronal TIRM imaging is effective in the diagnosis and depiction of sacral plexus injury,therefore it can be used as conventional sequence in sacral plexus examination to detect sacral plexus avulsion.
8.Optical coherence tomography angiography in retinal vein occlusion
Yu SU ; Changzheng CHEN ; Zuohuizi YI ; Lan YU ; Yishuang XU ; Chaoqun LIANG
Chinese Journal of Ocular Fundus Diseases 2016;32(4):357-361
Objective To observe the characteristics of optical coherence tomography (OCT) angiography (OCTA) in retinal vein occlusion (RVO).Methods Prospective and observational study.Clinical examination of 81 consecutive patients (86 eyes) diagnosed with RVO were included in the study,in which the branch retinal vein occlusion in 47 eyes,central retinal vein occlusion in 39 eyes.Forty-five patients were male and 36 patients were female.Aged from 28 to 76 years old,the mean age was (55.36±10.01) years old.Comprehensive optical and imaging examination were performed,including fundus photography,fundus fluorescein angiography (FFA),spectral domain OCT,en face OCT and OCTA.The retinal blood flow imaging scan mode and the optic disc blood flow imaging scan mode were performed,the scanning region in the macular area were 3 mm × 3 mm,6 mm × 6 mm,8 mm × 8 mm respectively,around the optic disc were 3 mm × 3 mm and 4.5 mm × 4.5 mm.Each region scans 2 times.The characteristics of foveal avascular zone change,macular edema,non-perfusion and optical disc edema in OCTA and their corresponding FFA and en face OCT were observed.Results By OCTA,67 eyes (77.9%) for foveal avascular zone change,23 eyes (26.7%) for macular edema,40 eyes (46.5%) for non-perfusion,and 33 eyes (38.4%) for optical disc edema can be detected.The foveal avascular zone change can be indentified as the tranformation,destruction and even vanish of the arch in superfacial layer of retinal macular area,acompanied with the dilatation and thickening of capillary vessels,the occlusion and expanding of capillary vessels arounded the foveal avascular zone in the deep layer of macular area.Those performances were more clear than FFA.The main expression of macular edema was low signal and was not as clear as en face OCT.The tortuosity and expansion of retinal vessels,density decreasing and even occlusion or abnormal traffic branch of capillary vessels can be observed in non-perfusion.These observations were similar to FFA.However,pieces of highly signal identical with non-perfusion area can b.e detected in chroid capillary.The representation of optical disc edema was the brush-like expanding of capillary vessels aroud optical disc.Conclusions OCTA can help for observing the abnormal changing of capillary vessels in foveal avascular zone and macular edema,non-perfusion and optical disc edema.Foveal avascular zone change showed occlusion and expanding of capillary vessels around the foveal avascular zone in the deep layer of macular area.Macular edema showed the weak signal.Non-perfusion showed tortuosity and expansion of retinal vessels,density decreasing and even occlusion or abnormal traffic branch of capillary vessels.Optical disc edema showed brush-like expanding of capillary vessels around optical disc.
9.Controlled live dendritic cell vaccine mediates potent antitumor immune responses
Yu KANG ; Congjian XU ; Xishi LIU ; Xinhua ZHANG ; Chaoqun WU ; Cuiping ZHONG ; Jianren GU ;
Chinese Journal of Obstetrics and Gynecology 2000;0(10):-
Objective To investigate the efficiency of antitumor immune responses induced by a controlled live dendritic cell(DC)vaccine Methods DC precursors were isolated from Fischer 344 rat bone marrow and cultured with granulocyte macrophage colony stimulating factor and interleukin 4 The rat ovarian tumor cell line NuTu 19 was genetically modified by retroviral mediated suicide gene(HSV 1 TK), and the positive clones were selected using G418 Live DC vaccine was then fused with DC and NuTu 19/TK cell by polyethylene glycol The characteristics of live DC vaccine were assayed with flow cytometry and confocal laser scanning microscopy The specific expression of HSV 1 TK gene in live DC vaccine was evaluated by RT PCR and western blot The sensitivity of live DC vaccine to ganciclovir (GCV) was evaluated by methylthiazoletetrazolium assay In vivo, rats vaccinated twice with live DC vaccine were compared to those vaccinated with killed DC vaccine, unfused DC and NuTu 19/TK cell or phosphate buffered saline Seven days following the last immunization, the rats were sacrificed to test the specific cytotoxic T lymphocyte (CTL) activity by lactate dehydrogenase release assay, or challenged with NuTu 19 and tumor incidence was observed Results The fusion efficiency was approximately (23?14) Live DC vaccine displayed an up regulated expression of major histocompatibility complex (MHC) IIOX6 (87 6?3 4)%, costimulatory molecule B 1 2 (71 1?9 3)%, integrin OX 62 (68 0?7 4)%, and adhesion ICAM 1 (77 1?2 0)%, and specifically expressed HSV 1 TK gene. Our data showed that spleen T lymphocytes from rats vaccinated with live vaccine displayed enhanced CTL aetivity (61 8?8 3)% contrast to that of rats vaccinated with killed vaccines (26 0?3 8)% ( P
10.Influencing factors of mental health of junior nurses
Hong XU ; Yebin NI ; Liya WANG ; Chaoqun RUAN ; Yichao TU ; Jian SHI
Modern Clinical Nursing 2017;16(2):75-78