1.The correlation between up-regulation of cyclooxygenase-2 expression and hepatocellular carcinoma angiogenesis
Chaohui ZOU ; Zhongyou SHENG ; Binsheng XIAO ; Xiao ZHOU ; Jinahong LOU ; Li ZHANG ; Zhongcheng KANG
Chinese Journal of General Surgery 1993;0(01):-
Objective To explore the correlation between up-regulation of cyclooxygenase-2(COX-2) (expression) and hepatocellular carcinoma(HCC) angiogenesis.Methods The expression of COX-2,vascular endothelial growth factor(VEGF)、basic fibroblast growth factor(bFGF) and angiopoientin-2(Ang-2) were examined in eighty matched sets of HCC specimens using immunohistochemistry and reverse (transcription-polymerase) chain reaction(RT-PCR).Results In HCC,the expression rate of COX-2,VEGF,bFGF and Ang-2 was 75.0%,62.5%,60.0% and 61.25%,respectively.(Immunohistochemical) staining scores of VEGF、bFGF and Ang-2 were 5.98?1.16,4.57?0.26 and(5.87)?0.12,respectively in strongly postive group of COX-2;and were 3.30?0.22,2.61?0.16 and 2.63?0.13,respectively in moderately weak postive group of COX-2.The expression rates of VEGF,(bFGF) and Ang-2 were 100.0%(95/95),94.29%(33/35) and 97.14%(34/35),respectively in strongly postive group of COX-2;and were 60.0%(15/25),60.0%(15/25) and 60.0%(15/25),respectively in moderately weak postive group of COX-2.There was significant difference in HCC(angiogenesis) between the two groups(P
2.The application effect of catheter management software in emergency intensive care unit
Chaohui JI ; Huibin PAN ; Xiaoyue ZOU ; Xianquan HU ; Haoxu ZHU ; Chunmiao ZHONG ; Xiaohong WEN
Chinese Journal of Postgraduates of Medicine 2016;39(11):976-980
Objective To assess the application effect of the catheter management software on the management of Indwelling urinary catheter in the Emergency intensive care unit (EICU). Methods A prospective control study of targeted surveillance of catheter-associated urinary tract infection was conducted from January 2014 to December 2015 in EICU. The patients were divided into two groups. The patients in control group (131 patients) were treated from January 1, 2014 to December 31, 2014 and received routine catheter management, and the patients in test group (135 patients) were treated from January 1, 2015 to December 31, 2015, and received catheter management by software. The catheter management software was developed and applied, and the process specification which collaborated with the software was established. The quality of the catheter management including the omission rate of the catheter management, the rate of urinary catheter-associated urinary tract infections (CAUTI) and the rate of catheter used etc were evaluated after the software's application. Results Through software applications, the omission rate of the catheter management, the omission rate of urine drainage bag replacementand the omission rate of urinary catheter replacement in test group were significantly lower than those in control group:0 vs. 36.64%(48/131), 0 vs. 15.27%(20/131) and 0 vs. 9.92%(13/131), P<0.01 or<0.05. The performance rate of catheter daily management in test group was significantly higher than that in control group: 99.26%(134/135) vs. 64.12%(84/131), P<0.01. The rate of CAUTI in test group was significantly lower than that in control group: 1.90‰ vs. 9.16‰, χ2=4.843, P=0.028. The rate of catheter used in test group was significantly lower than that in control group: 60.74%(82/135) vs. 73.28%(96/131), P<0.01. Conclusions The development and the establishment of the management software can improve the rate of implement, and declinethe rate of CAUTI.
3.Comparison of effects of constant pressure urination and timed urination during indwelling catheterization in elderly patients with coma in emergency intensive care unit
Xiaoyue ZOU ; Jinlan YAO ; Hui HAN ; Huibin PAN ; Tao ZOU ; Chaohui JI ; Yaqian WEI
Chinese Journal of Modern Nursing 2019;25(5):573-576
Objective? To compare the effects of constant pressure urination and timed urination during indwelling catheterization in elderly patients with coma in the emergency intensive care unit (EICU). Methods? Totally 100 elderly patients with coma admitted in EICU, the First Affiliated Hospital of Huzhou University from January 2015 to June 2017 were selected by convenient sampling. The 49 patients admitted from January 2015 to March 2016 were included into the control group, while the 51 patients admitted between April 2016 and June 2017 were included into the treatment group. Patients in the control group were allowed urination every 3-4 hours, while patients in the treatment group were monitored for continuous bladder pressure using a
4.Shanghai expert consensus on remote verification system of blood distribution in medical institutions
Zhanshan ZHA ; Mi JIANG ; Yuanshan LU ; Qingqing MA ; Baohua QIAN ; Ruiming RONG ; Chaohui TANG ; Xiaofeng TANG ; Jiang WU ; Rong XIA ; Tongyu ZHANG ; Xi ZHANG ; Rong ZHOU ; Zhengrong ZOU
Chinese Journal of Blood Transfusion 2022;35(8):783-785
In order to solve the difficulties and challenges in the implementation of the original blood distribution and collection regulations caused by the expansion of hospital area, the extension of blood transfer time, the changeability of blood transfer environment, and the strain of personnel due to the increase of workload, as well as to ensure the accuracy of the information throughout blood remote verification and distribution and the safety of clinical blood transfusion, , Shanghai experts related to clinical transfusion and blood management had made a systematic study on the applicable scope and management rules of remote verification of blood distribution and collection, and formulated this Expert Consensus combined with the development status of digital, intelligent and remote communication technologies, so as to provide corresponding guidance for clinical medical institutions in line with the changes in reality.