1.Clinical application of three-dimensional printing technology combined with customized bone plate in the treatment of acetabulum fracture.
Yan-Chao ZANG ; Quan-Yong ZHAO ; Li YANG ; Jin-Zeng ZUO ; Wei QI ; Wei-Dong LIANG ; Jie XING
China Journal of Orthopaedics and Traumatology 2025;38(2):203-207
OBJECTIVE:
To explore the application value and clinical effect of 3D printing combined with customized bone plate in the treatment of acetabular fracture.
METHODS:
From June 2020 to June 2022, 11 patients with acetabular fractures underwent preoperative planning using 3D printing technology and were treated with customized bone plates including 8 males and 3 females, aged 25 to 66 years old. The fractures were classified according to Letournel-Judet:4 posterior wall fractures, 2 T-type fractures, 2 transverse posterior wall fractures, 2 double column fractures, and 1 anterior column with posterior semi-transverse fractures. The operative time, intraoperative blood loss, intraoperative fluoroscopy times, postoperative drainage volume, postoperative fracture healing time, and hip function score were recorded and analyzed.
RESULTS:
The operation time of 11 patients was 80 to 150 min, intraoperative blood volume was 150 to 700 ml, fluoroscopy frequency was 2 to 6, postoperative drainage flow was 60 to 195 ml, and the fracture healing time was 2.5 to 6.0 months. Fracture reduction was evaluated according to Matta score:anatomical reduction in 3 cases and satisfactory reduction in 8 cases. Eleven patients were followed up for 7 to 18 months. The hip Merle d'Aubigne function scores were excellent in 6 cases, good in 3 cases, fair in 1 case and poor in 1 case. Incision fat liquefaction occurred in 1 case and obturator nerve traction in 1 case.
CONCLUSION
The application of 3D printing technology combined with customized bone plates in the treatment of acetabular fracture is effective. In addition, the printed model can provide the operator with the results of the three-dimensional shape of the fracture, which is convenient for surgical reduction and effectively improves the efficiency of surgery.
Humans
;
Female
;
Male
;
Middle Aged
;
Acetabulum/surgery*
;
Printing, Three-Dimensional
;
Adult
;
Aged
;
Bone Plates
;
Fractures, Bone/surgery*
;
Fracture Fixation, Internal/methods*
2.Preparation and application of CD318 monoclonal antibody.
Ke CHAO ; Ziyang WANG ; Jie ZHAO ; Meijia YANG
Chinese Journal of Cellular and Molecular Immunology 2025;41(9):818-826
Objective To prepare CD318-specific monoclonal antibodies and evaluate their specificity, affinity, and application in immunological detection, laying the foundation for the development of CD318-targeted antibody drugs. MethodsCD318 protein was expressed and purified, and was used as an antigen to immunize mice, then mice with higher antiserum titers were screened. We prepared CD318-specific monoclonal antibodies through cell fusion and monoclonal screening, and the specificity, affinity, and application of the obtained monoclonal antibodies in immunological assays were evaluated. Then we constructed a CD318/CD3-targeting bispecific antibody and assessed its impact on T-cell cytotoxicity. Results Thirteen monoclonal antibodies were successfully generated, with the hybridoma clone 13-8-G2 exhibiting the highest titer, strongest specificity, and broadest applicability. The antibody was identified as an IgG1 isotype with a kappa light chain. The variable region of the light chain measured 318 bp, while the heavy chain variable region was 357 bp, yielding an affinity constant of approximately 7.68×109. The specificity of CD318 was confirmed using flow cytometry and immunofluorescence assays. Additionally, a CD318/CD3-targeting bispecific antibody was constructed using the variable regions of this CD318 monoclonal antibody, which demonstrated enhanced T-cell cytotoxicity. Conclusion High-affinity and highly specific CD318 monoclonal antibodies were successfully prepared, laying a foundation for the development of therapeutic antibodies targeting CD318.
Animals
;
Antibodies, Monoclonal/biosynthesis*
;
Mice
;
Antibodies, Bispecific/immunology*
;
Humans
;
Mice, Inbred BALB C
;
Antibody Specificity/immunology*
;
CD3 Complex/immunology*
;
Antigens, CD/genetics*
;
T-Lymphocytes/immunology*
;
Hybridomas/immunology*
;
Female
3.Effect of Acupuncture on Clinical Symptoms of Patients with Intractable Facial Paralysis: A Multicentre, Randomized, Controlled Trial.
Hong-Yu XIE ; Ze-Hua WANG ; Wen-Jing KAN ; Ai-Hong YUAN ; Jun YANG ; Min YE ; Jie SHI ; Zhen LIU ; Hong-Mei TONG ; Bi-Xiang CHA ; Bo LI ; Xu-Wen YUAN ; Chao ZHOU ; Xiao-Jun LIU
Chinese journal of integrative medicine 2025;31(9):773-781
OBJECTIVE:
To evaluate the clinical effect and safety of acupuncture manipulation on treatment of intractable facial paralysis (IFP), and verify the practicality and precision of the Anzhong Facial Paralysis Precision Scale (Eyelid Closure Grading Scale, AFPPS-ECGS).
METHODS:
A multicentre, single-blind, randomized controlled trial was conducted from October 2022 to June 2024. Eighty-nine IFP participants were randomly assigned to an ordinary acupuncture group (OAG, 45 cases) and a characteristic acupuncture group (CAG, 44 cases) using a random number table method. The main acupoints selected included Yangbai (GB 14), Quanliao (SI 18), Yingxiang (LI 20), Shuigou (GV 26), Dicang (ST 4), Chengjiang (CV 24), Taiyang (EX-HN 5), Jiache (ST 6), Fengchi (GB 20), and Hegu (LI 4). The OAG patients received ordinary acupuncture manipulation, while the CAG received characteristic acupuncture manipulation. Both groups received acupuncture treatment 3 times a week, with 10 times per course, lasting for 10 weeks. Facial recovery was assessed at baseline and after the 1st, 2nd and 3rd treatment course by AFPPS-ECGS and the House-Brackmann (H-B) Grading Scale. Infrared thermography technology was used to observe the temperature difference between healthy and affected sides in various facial regions. Adverse events and laboratory test abnormalities were recorded. The correlation between the scores of the two scales was analyzed using Pearson correlation coefficient.
RESULTS:
After the 2nd treatment course, the two groups showed statistically significant differences in AFPPS-ECGS scores (P<0.05), with even greater significance after the 3rd course (P<0.01). Similarly, H-B Grading Scale scores demonstrated significant differences between groups following the 3rd treatment course (P<0.05). Regarding temperature measurements, significant differences in temperatures of frontal and ocular areas were observed after the 2nd course (P<0.05), becoming more pronounced after the 3rd course (P<0.01). Additionally, mouth corner temperature differences reached statistical significance by the 3rd course (P<0.05). No safety-related incidents were observed during the study. Correlation analysis revealed that the AFPPS-ECGS and the H-B Grading Scale were strongly correlated (r=0.86, 0.91, 0.93, and 0.91 at baseline, and after 1st, 2nd, and 3rd treatment course, respectively, all P<0.01).
CONCLUSIONS
Acupuncture is an effective treatment for IFP, and the characteristic acupuncture manipulation enhances the therapeutic effect. The use of the AFPPS-ECGS can more accurately reflect the recovery status of patients with IFP. (Trial registration No. ChiCTR2200065442).
Humans
;
Acupuncture Therapy/methods*
;
Facial Paralysis/therapy*
;
Female
;
Male
;
Middle Aged
;
Adult
;
Treatment Outcome
;
Acupuncture Points
;
Aged
4.Association between acupuncture and live birth rates after fresh embryo transfer: A cohort study based on different propensity score methods.
Xiao-Yan ZHENG ; Zi-Yi JIANG ; Yi-Ting LI ; Chao-Liang LI ; Hao ZHU ; Zheng YU ; Si-Yi YU ; Li-Li YANG ; Song-Yuan TANG ; Xing-Yu LÜ ; Fan-Rong LIANG ; Jie YANG
Journal of Integrative Medicine 2025;23(5):528-536
OBJECTIVE:
To explore the association between acupuncture during controlled ovarian hyperstimulation (COH) and the live birth rate (LBR) using different propensity score methods.
METHODS:
In this retrospective cohort study, eligible women who underwent a COH were divided into acupuncture and non-acupuncture groups. The primary outcome was LBR, as determined by propensity score matching (PSM). LBR was defined as the delivery of one or more living infants that reached a gestational age over 28 weeks after embryo transfer. The propensity score model encompassed 16 confounding variables. To validate the results, sensitivity analyses were conducted using three additional propensity score methods: propensity score adjustment, inverse probability weighting (IPW), and IPW with a "doubly robust" estimator.
RESULTS:
The primary cohort encompassed 9751 patients (1830 [18.76%] in the acupuncture group and 7921 [81.23%] in the non-acupuncture group). Following 1:1 PSM, a higher LBR was found in the acupuncture cohort (41.4% [755/1824] vs 36.4% [664/1824], with an odds ratio of 1.23 [95% confidence interval, 1.08-1.41]). Three additional propensity score methods produced essentially similar results. The risk of serious adverse events did not significantly differ between the two groups.
CONCLUSION
This retrospective study revealed an association between acupuncture and an increased LBR among patients undergoing COH, and that acupuncture is a safe and valuable treatment option. Please cite this article as: Zheng XY, Jiang ZY, Li YT, Li CL, Zhu H, Yu Z, Yu SY, Yang LL, Tang SY, Lü XY, Liang FR, Yang J. Association between acupuncture and live birth rates after fresh embryo transfer: A cohort study based on different propensity score methods. J Integr Med. 2025; 23(5):528-536.
Humans
;
Female
;
Propensity Score
;
Embryo Transfer
;
Adult
;
Acupuncture Therapy
;
Retrospective Studies
;
Pregnancy
;
Live Birth
;
Birth Rate
;
Cohort Studies
5.Association between Fish Consumption and Stroke Incidence Across Different Predicted Risk Populations: A Prospective Cohort Study from China.
Hong Yue HU ; Fang Chao LIU ; Ke Yong HUANG ; Chong SHEN ; Jian LIAO ; Jian Xin LI ; Chen Xi YUAN ; Ying LI ; Xue Li YANG ; Ji Chun CHEN ; Jie CAO ; Shu Feng CHEN ; Dong Sheng HU ; Jian Feng HUANG ; Xiang Feng LU ; Dong Feng GU
Biomedical and Environmental Sciences 2025;38(1):15-26
OBJECTIVE:
The relationship between fish consumption and stroke is inconsistent, and it is uncertain whether this association varies across predicted stroke risks.
METHODS:
A cohort study comprising 95,800 participants from the Prediction for Atherosclerotic Cardiovascular Disease Risk in China project was conducted. A standardized questionnaire was used to collect data on fish consumption. Participants were stratified into low- and moderate-to-high-risk categories based on their 10-year stroke risk prediction scores. Hazard ratios ( HRs) and 95% confidence intervals ( CIs) were estimated using Cox proportional hazard models and additive interaction by relative excess risk due to interaction (RERI), attributable proportion (AP), and synergy index (SI).
RESULTS:
During 703,869 person-years of follow-up, 2,773 incident stroke events were identified. Higher fish consumption was associated with a lower risk of stroke, particularly among moderate-to-high-risk individuals ( HR = 0.53, 95% CI: 0.47-0.60) than among low-risk individuals ( HR = 0.64, 95% CI: 0.49-0.85). A significant additive interaction between fish consumption and predicted stroke risk was observed (RERI = 4.08, 95% CI: 2.80-5.36; SI = 1.64, 95% CI: 1.42-1.89; AP = 0.36, 95% CI: 0.28-0.43).
CONCLUSION
Higher fish consumption was associated with a lower risk of stroke, and this beneficial association was more pronounced in individuals with moderate-to-high stroke risk.
Humans
;
China/epidemiology*
;
Male
;
Female
;
Stroke/etiology*
;
Middle Aged
;
Prospective Studies
;
Incidence
;
Aged
;
Animals
;
Fishes
;
Risk Factors
;
Diet
;
Seafood
;
Adult
;
Cohort Studies
7.5.0T MRI for quantifying proton density fat fraction of liver
Jianxian LIU ; Zhensong WANG ; Xin WANG ; Ning TIAN ; Peng CHEN ; Dan YU ; Yanxing YANG ; Chuanli CHENG ; Chao ZOU ; Jie GAN
Chinese Journal of Medical Imaging Technology 2024;40(5):671-676
Objective To observe the value of 5.0T MRI for quantifying proton density fat fraction(PDFF)of liver.Methods Liver chemical shift encoded(CSE)MR scanning were prospectively performed using 5.0T,3.0T and 1.5T scanner in 30 volunteers,respectively,and CSE-PDFF were measured.Then MR spectroscopy(MRS)were performed using 5.0T and 1.5T scanner,respectively,and MRS-PDFF were also measured.The consistency of liver PDFF measured on different images was observed,and the value of 5.0T MRI for liver PDFF was analyzed.Results The overall consistencies of liver CSE-PDFF measured with 5.0T,3.0T and 1.5T MR scanner were all good(all ICC>0.75,all P<0.001).The consistency of liver CSE-PDFF based on 5.0T and 3.0T,1.5T MR scanner were both good(ICC=0.989,0.992,both P<0.001).The overall consistencies of CSE-PDFF based on 5.0T MR and MRS-PDFF based on 5.0T and 1.5T MR were both good(both ICC>0.75,both P<0.001).CSE-PDFF had good consistency with MRS-PDFF based on same 5.0T MR scanner(ICC=0.988,P<0.001),and CSE-PDFF based on 5.0T had good consistency with MRS-PDFF based on 1.5T MR scanner(ICC=0.978,P<0.001).Conclusion 5.0T MRI had high value for quantifying liver PDFF.
8.Consistency of 5.0T and 1.5T MR spectroscopy for quantitating proton density fat fraction of liver
Jianxian LIU ; Zhensong WANG ; Zhengyi LI ; Xin WANG ; Dan YU ; Yanxing YANG ; Chuanli CHENG ; Chao ZOU ; Shuo CHEN ; Jie GAN
Chinese Journal of Medical Imaging Technology 2024;40(5):677-681
Objective To observe the consistency of 5.0T and 1.5T MR spectroscopy(MRS)for quantitating proton density fat fraction(PDFF)of liver.Methods Lipid emulsion models with lipid content of 0,5%,10%,15%,20%,25%and 30%were prepared.1H-MRS were collected using 5.0T and 1.5T MR scanners,respectively,and PDFF were obtained with jMRUI software.Totally 23 people,including 11 cases of fatty liver and 12 healthy adults were prospectively collected,and volume of interest(VOI)in the liver were selected to acquire 1H-MRS,and PDFF were obtained with jMRUI software and corresponding workstation,respectively.The consistencies of PDFF measured with different methods were analyzed.Results PDFF of lipid emulsion models with lipid content of 0,5%,10%,15%,20%,25%and 30%measured with jMRUI software and workstations based on 5.0T and 1.5T 1H-MRS all had good consistencies and being positively correlated,so were PDFF of liver tissue measured with jMRUI software and workstations based on 5.0T and 1.5T 1H-MRS.Conclusion 5.0T and 1.5T 1H-MRS had good consistency for quantitating liver PDFF.Measuring liver PDFF with workstation in clinical practice was helpful to simplifying workflow.
9.Reliability of ICF dysfunction combination in rehabilitated inpatients
Weiwen XU ; Yang CHEN ; Chao TANG ; Kun CHEN ; Teng MA ; Dan LI ; Jie XIANG
China Modern Doctor 2024;62(8):45-50
Objective To explore the inter-rater and within-rater reliability of the 30 categories of the International Classification of Functioning Disability,and Health(ICF)dysfunction set(ICF generic-30 set)in clinical function assessment,to provide a basis for its clinical application.Methods Ninety patients from the Neurorehabilitation Department of the First People's Hospital of Suqian City were enrolled in this study.All patients were evaluated by the same functional evaluator's ICF dysfunction combination at the two time points of admission and discharge for the internal reliability analysis of the evaluator.Thirty patients in the neurorehabilitation department were randomly selected to be evaluated by two ICF function evaluators at the same time to conduct test-retest reliability analysis among evaluators.The internal consistency of the Cronbach's α coefficient test scale,and the intra-group correlation coefficient(ICC)test inter-rater reliability and within-rater reliability.Results The Cronbach's α coefficients of the combination of ICF dysfunction,physical function and activity,and participation in the two subscales were 0.941,0.717,and 0.942,respectively.The inter-rater reliability analysis showed that the ICC of the total score of the scale and the total scores of physical function and activity and participation in the two subscales were 0.998,0.971,0.999(P<0.01),and the inter-rater reliability good;the internal reliability analysis of the evaluator showed that the total score of the scale and the total scores of physical function and activity and participation in the two subscales were 0.988,0.917,0.991(P<0.01),except that b640 sexual function is not applicable,and b130 energy Harmony drive function ICC is 0.558,b280 pain ICC is 0.409,ICC of other combination items is 0.838-0.986(P<0.01),the evaluator's internal reliability is good;90 patients'ICF dysfunction combination scale has 30 categories.The comparison between admission and discharge was statistically significant except that b640 was not applicable for sexual function(P<0.05).Conclusion The combination of ICF dysfunction has good internal consistency and inter-evaluator and intra-evaluator reliability in the functional evaluation of patients in neurorehabilitation department.
10.Novel 18F-FES PET/CT in Non-invasive Functional Diagnosis of Delayed Lung Metastasis Presented with Horner Syndrome in a Metastatic Breast Cancer Patient
Ru YAO ; Zhixin HAO ; Yang QU ; Chao ZHANG ; Weijia LI ; Jie LANG ; Bo PAN ; Yidong ZHOU ; Qiang SUN ; Li HUO
Medical Journal of Peking Union Medical College Hospital 2024;15(3):702-707
Hormonal receptor positive human epidermal receptor 2 negative (HR+/HER2-) is the commonest molecular subtype of breast cancer (BC). Patients with HR+/HER2- BC may manifest clinically a late recurrence whose BC metastasizes 10-15 years post-operatively. We report one case who presented with pulmonary mass in upper lobe of lung and Horner syndrome 16 years after BC surgery. FDG PET/CT suggested pulmonary malignancy but could not differentiate between primary or metastatic cancer when invasive biopsy was quite risky. Novel 18F-FES PET/CT facilitated the non-invasive functional diagnosis of estrogen-receptor positive (ER+) pulmonary metastasis of BC, and the patient experienced partial response (PR) after CDK4/6 inhibitor and aromatase inhibitor as endocrine therapy. This article reviews the diagnosis and treatment process of this case, to provide guidance for non-invasive global evaluation of ER status among metastatic HR+/HER2- BC patients with 18F-FES PET/CT.

Result Analysis
Print
Save
E-mail