1.Determination of the Content of Entecavir and Its Related Substances by HPLC
Xiaofang HUO ; Chao FU ; Xiaohai TANG ; Yongmei XIE ; Hang SONG
China Pharmacy 2005;0(16):-
OBJECTIVE: To establish a HPLC method for the determination of content of entecavir and its related substances. METHODS: The HPLC condition was consisted of a Luna C18 column with a column temperature at 25 ℃, using gradient eluate method, the mobile phase was acetonitrile,with a flow rate of 1.0 mL?min-1 and detection at 254 nm. RESULTS: The calibrated linear curve of entecavir was within 0.033 45~0.167 2 mg?mL-1(r=0.999 98). The average recovery was 100.09%,RSD=0.20%, The content of related substance was 0.54%~1.48%. CONCLUSION: This accurate and reliable HPLC method is applicable for the quality control of entecavir and its related substances.
2.Comparison ultrasound localization method with traditional touch method on radial artery cannulation in infants
Guoliang LIU ; Lianghong HUO ; Xiaoxue WANG ; Chao ZHENG ; Tiehua ZHENG
The Journal of Clinical Anesthesiology 2014;(6):586-588
Objective To explore the effect on ultrasound localization method with radial artery cannulation in infants.Methods Sixty infants (1 month-1year old)undergoing elective surgical proce-dures required artery pressure,were randomly divided into two groups:ultrasound localization group (group B):the infants were used of portable B ultrasound probe in the wrist with two dimensional ul-trasound image to determine the body position of the radial artery;control group (group C):tradi-tional palpation determine the radial artery puncture position.One puncture success rate,total punc-ture success rate,the period of puncture time and incidence of complications were recorded;MAP, the radial artery diameter,the vertical distance from the ultrasound probe to the skin and the length from the puncture spot to the radial artery were also measured.Results The success rate of first puncture in group B was higher than that of group C (P <0.05),the times of puncture and procedure time were significantly less than those of group C (P <0.05),the incidence of hematoma was lower than that in group C (P <0.05).Conclusion The application of ultrasound-guided method for radial artery cannulation is safe and reliable with accurate localization,highly successful rate of puncture at first time,lower complication and shorter time for placement.
3.A margin from the clinic target volume to the planning target volume for esophagus carcinoma
Yankun CAO ; Zhihui TIAN ; Junjie HUO ; Chao GAO ; Zifeng CHI
The Journal of Practical Medicine 2014;(13):2064-2067
Objective To measure the setup errors and organ movements of patients with esophagus carcinoma during radiotherapy and find a reasonable margin from the clinic target volume (CTV) to the planning target volume (PTV). Methods (1) Set-up veri cation: Forty-two cases of untreated esophageal cancer were enrolled into this study. The physicist firstly made the planning according to the doctor requests and ensured the best distribution at the target. Thereafter, the 0° and 90° digitally reconstructed radiograph (DRR) was transmitted to the iView GT workshop. Meanwhile, two copies of cross-cut electronic portal image (EPI) were required before radiotherapy. Two doctors confirmed the variance of the osteal mark from the EPI and DRR,and output a 3D direction (left to right, superior to inferior, anterior to posterior) of the setup errors through the iView GT software. (2)Breathing motion:Ten cases of untreated esophageal cancer were enrolled into this study.Three distinct breathing levels were deflned: FB (free breathing), EBH (expiration with breath-held) and IBH (inspiration with breath-held). We gave the treatment planning in FB, then by moving the isocenter to EBH and IBH, we recalculated the dose distribution without changing the field angle, shape and weighing (Mus). Displacements were analyzed at four points (anterior, posterior, right lateral and left lateral) and five levels of target (upper, quarter, isocenter, three-quarter and lower). Results (1) The systematic setup errors were -0.23 cm, -0.02 cm and -0.06 cm, and the random errors were 0.44 cm, 0.45 cm and 0.44 cm at the direction of left to right(LR), superior to inferior (SI), anterior to posterior(AP), respectively. (2) The organ movements were 0.3 cm, 0.6cm and 0.3cm at the LR, SI, AP, respectively. Conclusions As an alternative, the root-sum-of-squares of set-up error and organ motion are suggested by σtot=√ (σITV2+σSM2). The CTV to PTV margins are 0.8cm left to right, 0.78cm superior to inferior, 0.5cm anterior to posterior.
4.Application of 123/131I-MIBG in the diagnosis and treatment of pediatric neuroblastoma
Yanlei HUO ; Danyang WANG ; Hui WANG ; Chao MA
Chinese Journal of Nuclear Medicine and Molecular Imaging 2017;37(3):173-176
As a type of neuroendocrine tumors, neuroblastoma (NB) is the most common extra-cranial solid tumor of childhood.123/131I-MIBG scintigraphy is a standard imaging modality in staging and evaluating therapeutic effect of pediatric NB with high accuracy.131I-MIBG treatment is effective for children with high-risk and relapsed/refractory NB.Combined with chemotherapy, stem cell transplantation, 131I-MIBG treatment shows efficacy in decreasing the relapse of pediatric NB.This review summarizes the application of MIBG scintigraphy and 131I-MIBG treatment for pediatric NB.
5.Physical properties of metal sulfides and research advances in tumor photothermal therapy
Feng HUO ; Dengyue YUAN ; Chao YOU ; Wenqing DENG ; Feng YANG
Military Medical Sciences 2016;40(12):958-963
Photothermal therapy ( PTT) is a new treatment for cancer .Metal sulfide quantum dots can serve as good PTT agents thanks to their excellent optical , physical and chemical properties .This paper introduced the basic principles of PTT, evaluation methods and properties of quantum dots .Also, we reviewed the research progress in metal sulfide quantum dots, which have good infrared plasmon response capabilities and localized surface plasmon resonance effect in PTT .In combination with the characteristics of metal sulfide quantum dots , this review offered a vision of the physical and chemical processes which can be used in PTT and the developments of this novel cancer therapy offered a vision of the .
7.Value of 18 F-FDG PET/CT for prognosis evaluation in patients with small cell lung cancer
Youjing ZHENG ; Li HUO ; Jiantao BA ; Chao REN ; Fang LI
Chinese Journal of Nuclear Medicine and Molecular Imaging 2015;(6):442-445
Objective To evaluate the prognostic value of 18 F?FDG PET/CT in untreated small cell lung cancer ( SCLC) . Methods A total of 49 SCLC patients( 35 males, 14 females, median age 61 years) with pathologically confirmed SCLC had underwent 18 F?FDG PET/CT scan before treatment from January 2008 to December 2013 and were retrospectively analyzed in this study. Clinical staging were mainly deter?mined by 18 F?FDG PET/CT scan. Performance status ( PS) was acquired according to the clinical symptoms before PET examination. Patients were followed up for at least 6 months and the survival interval was recor?ded. Two?sample t test, Kaplan?Merier, log?rank and Cox regression analysis were used for statistical analy?sis. Results (1)Among 49 patients, 20 died during the follow?up, 1 patient was lost to follow?up, and 45 patients(91.84%) had metastasis. Patients with limited disease (LD) and extensive disease (ED) were 27 and 22 respectively according to 18F?FDG PET/CT imaging. (2)The median OS was 23.68 months and me?dian PFS was 19.93 months. LD patients had significantly longer OS and PFS than ED patients (35.30 months vs 12.57 months, 28.87 months vs 11.30 months;χ2=18.810, 13.647, both P<0.05). (3)SUVmax of primary tumor ranged from 1.97 to 21.50. The SUVmax of primary foci had no difference between LD(8.27± 3.14) and ED(9.68±5.36)patients(P>0.05). SUVmax of primary tumor showed no significant correlation with OS and PFS (both P>0.05).There were no significant differences in OS and PFS between low SUVmax group and high SUVmax group in both LD and ED patients (χ2=0.001-0.565, all P>0.05). (4) Staging based on 18 F?FDG PET/CT results and PS score were independent prognostic factors ( hazard ratios:3.93, 5?00, both P<0.05) , while SUVmax showed no significant prognostic value. Conclusions PS score before PET scan and imaging staging based on 18 F?FDG PET/CT results are independent prognostic factors. The predictive value of primary foci SUVmax needs further investigation.
8.Effect of postoperative thyrotropin suppression on bone mineral density in postmenopausal women with differentiated thyroid carcinoma
Yanlei HUO ; Danyang WANG ; Shuqi WU ; Hui WANG ; Chao MA
Chinese Journal of Nuclear Medicine and Molecular Imaging 2017;37(4):212-215
Objective To investigate the effect of postoperative TSH suppression on bone mineral density (BMD) in postmenopausal women with DTC.Methods Postmenopausal women with postoperative DTC underwent thyroid residual ablation or 131I treatment for metastases at Xin Hua Hospital between September 2009 and December 2014 were enrolled and followed for 2 years.They were divided into suppressive TSH group (median TSH<0.30 mU/L;group 1) and non-suppressive group (median TSH≥0.30 mU/L;group 2).Lumber 1-4 BMD levels (T scores) were measured by a dual energy X-ray absorptiometry bone densitometer at baseline,1 year and 2 years after treatment.All patients had calcium and vitamin D supplementation after TSH suppression.The T scores were compared with Mann-Whitney u test and Kruskal-Wallis test.Results A total of 126 patients were enrolled and followed up for 2 years,including 65 with average age (57.65±6.65) years in group 1 and 61 with average age (56.19±7.17) years in group 2.The T scores in group 1 and group 2 at baseline were-1.70(-2.30,-0.55) and-1.30(-2.10,-0.30) (z=-1.660,P> 0.05).The difference of T scores was significant in group 1 at baseline,1-year follow-up and 2-year follow-up (-2.25(-2.48,-0.83),-1.95(-2.70,-0.60);H=6.244,P<0.05),but not significantly different in group 2 (H=1.102,P>0.05).The T values were different between the 2 groups both in 1-year follow-up and 2-year follow-up (z values:-2.170,-2.160,both P<0.05).Conclusions TSH suppression significantly increases the risk of postoperative osteoporosis.The BMD should be followed up annually in postmenopausal DTC patients.
9.Rapid screening of katG gene mutation in isoniazid-resistant Mycobacterium tuberculosis
Journal of Zhejiang University. Medical sciences 2002;31(3):178-180
OBJECTIVE: To evaluate the relationship between katG gene mutation and isoniazid (INH) resistance and to develop a rapid screening method of point mutation in the katG gene associated with MTB resistance. METHODS: Twenty-four clinical isolates of MTB with 8 INH resigtance isolates and 16 INH-sensitive isolates were analyzed by PCR-RFLP, with the H(37)Rv reference strain as the control. RESULTS: G-->C point mutations were detected in 7 of 8 isoniazid-resistant strains and no gene mutation was shown in 16 isoniazid-sensitive isolates. The sensitivity and specificity were 87.5 % and 100 % respectively. No katG gene sequence deletion was observed in any specimen. CONCLUSION: Our results suggest katG gene mutation is one of the most important mechanisms of INH-resistant TB. PCR-RFLP may be useful in detection of katG gene mutation.
10.Clinical significance of volume of epicardial adipose tissue and calcification score on evaluating the degree of coronary artery stenosis
Biao HE ; Tao ZHOU ; Li HUO ; Chao LI ; Long HE ; Qingle GUO
Clinical Medicine of China 2014;30(9):939-941
Objective To investigate the comparison of volume of epicardium adipose tissue and calcification score on evaluating the degree of coronary artery stenosis(CHD).Methods Two hundred and ten cases with suspected coronary artery disease scanned by the 64 multi slice CT (MSCT) were selected as our subjects.One hundred and forty-five cases were diagnosed non coronary heart disease by with < 50% coronary artery stenosis by coronary angiography and served as non-CHD group.Other 55 cases were diagnosed as CHD with coronary artery stenosis ≥ 50% and served as CHD group.The volume of epicardium adipose tissue and calcification score of all cases were calculated with Siemens definition workstation.Results The volume of epicardium adpose tissue and calcification score in patients of CHD group were (117.3 ± 57.6) cm3 and (413.3 ± 670.5) %,significant different from that of non-CHD group ((100.0 ± 46.5) cm3,(36.2 ± 118.5).The differences were statistically significant (t =2.316,6.564; P < 0.05,P < 0.01).ROC curves showed that the sensitivity and specificity of calcification score were higher than the methods of volume of epicardium adipose tissue in terms of the diagnosis of stenosis and coronary artery disease.Conclusion Calcification score is proved to be a better method of predicting the coronary artery stenosis.