1.The Response of Human Umbilical Vein Endothelial Cells Under Complicated Flow Conditions.
Chanil CHUNG ; Dong Ik KIM ; So Young YOO ; Chan Young PARK ; Byung Boong LEE ; Jun Keun CHANG
Journal of the Korean Society for Vascular Surgery 2001;17(1):16-23
PURPOSE: Endothelial cells (ECs) are exposed to continuous shear stress from their birth and also respond to the hemodynamic environmental changes which may be localizing factor in vascular diseases, such as atherosclerosis. The hemodynamic shear stress is implicated in the pathogenesis of atherosclerosis, thrombosis, and also restenosis. The objective of this study is to investigate the morphological and molecular biological changes of vein ECs under complicated flow flield which could occur in the anastomosis site of the autogenous vein bypass graft. METHOD: We developed a laminar flow chamber for the normal vessel and a sudden expansion flow chamber to simulate the recirculation or the stagnation zone of vascular graft. RESULT: Normal flow shear stress transformed ECs from random oriented polygonal, cobblestone shape to elongated shape aligned along the flow direction. However the stagnation and flow separation zone could not show the morphologic change of ECs and could be the region of low shear stress prone for intimal hyperplasia and atherosclerosis initiation. CONCLUSION: It also represents that the ECs can sense the magnitude and the direction of the flow shear stress and change their phenotype through the remodeling of the actin microfilaments.
Actin Cytoskeleton
;
Atherosclerosis
;
Endothelial Cells
;
Hemodynamics
;
Human Umbilical Vein Endothelial Cells*
;
Humans*
;
Hyperplasia
;
Parturition
;
Phenotype
;
Thrombosis
;
Transplants
;
Vascular Diseases
;
Veins
2.Expression of Matrix Metalloproteinase (MMP)-2, MMP-9, Tissue Inhibitor of Metalloproteinase (TIMP)-1 and TIMP-2 in Adenocarcinomas of The Gallbladder.
Jong Yup BAE ; Jinsub CHOI ; Hyun Cheol CHUNG ; Chanil PARK ; Young Nyun PARK
Korean Journal of Pathology 2003;37(1):1-9
BACKGROUND: Matrix metalloproteinase (MMP)-2 and MMP-9 degrade type IV collagen and are antagonized by the tissue inhibitors of metalloproteinase (TIMP)-2 and TIMP-1, respectively. METHODS: We studied by immunohistochemistry the expressions of MMP-2, MMP-9, TIMP-1 and TIMP-2 in 72 cases of adenocarcinoma of the gallbladder. RESULTS: The MMP-2, MMP-9 and TIMP-1 expressions were significantly higher in well/moderately differentiated adenocarcinomas than in poorly differentiated adenocarcinomas, in adenocarcinomas that had invaded the lamina propria/proper muscle than in those that had invaded the perimuscular connective tissue or beyond the serosa, and in adenocarcinomas with fungating growth than in those with infiltrative growth. The TIMP-2 expression showed a similar pattern without statistical significance. Regarding the status of lymph node metastasis, the MMP-2 expression was significantly higher in cases without lymph node metastasis. The MMP-2 and MMP-9 expressions were significantly related to those of TIMP-2 and TIMP-1, respectively, with regard to depth of invasion, differentiation, and growth patterns of the adenocarcinomas. CONCLUSIONS: MMP-2, MMP-9, TIMP-1 and TIMP-2 are suggested to play important roles in the progression to early invasion of adenocarcinomas, in which the function of MMP-2 is inhibited by TIMP-2.
Adenocarcinoma*
;
Collagen Type IV
;
Connective Tissue
;
Gallbladder Neoplasms
;
Gallbladder*
;
Immunohistochemistry
;
Lymph Nodes
;
Matrix Metalloproteinases
;
Neoplasm Metastasis
;
Serous Membrane
;
Tissue Inhibitor of Metalloproteinase-1
;
Tissue Inhibitor of Metalloproteinase-2*
;
Tissue Inhibitor of Metalloproteinases
3.Development of a New Blood Typing Kit Using the Microfluidics Separation Technique.
In Bum SUH ; Sook Won RYU ; Yongku LEE ; Dae Sung HUR ; Chanil CHUNG ; Jun Keun CHANG ; Chae Seung LIM
Korean Journal of Hematology 2007;42(4):392-396
BACKGROUND: Blood typing is an essential test for transfusion. Generally, blood typing is performed using a slide test, tube test or microcolumn agglutination test. The aims of this study were to develop a new blood typing kit using micromachining, microfluidics and microseparation methods, and to evaluate the clinical usefulness of the new blood typing kit. METHODS: We designed and manufactured a blood typing microchip using polydimethylsiloxane (PDMS), which contained a microchannel (25~200 micrometer). The blood sample and antisera to be tested were dropped on the microwell for movement and mixing by capillary action. Once agglutination occurred, the microchannel acts as a filter and the blood type was determined by observation by the naked eye. To evaluate the newtyping kit, we tested sensitivity using artificially diluted blood and compared the results of the new typing method with the slide and tube methods using 70 samples. RESULTS: The new blood typing kit could differentiate a +4~+2 agglutination reaction, but could not detect a +1 agglutination reaction as observed by the naked eye. Among 70 samples, the results of ABO and Rh typing by the new typing method (n=66, > or = +2 agglutination reaction by the column agglutination method) were in accord with the results of the tube and slide methods, but couldnot detect agglutination in all 4 clinical samples, below a +1 agglutination reaction. CONCLUSION: The new blood typing kit is inadequate for routine use in the clinical laboratory due to low sensitivity, but with further improvement, it can be used economically, conveniently and objectively for blood typing without any special equipment. Moreover, the microfludics and separation method may be broadly applicable in other tests using the hemagglutination method.
Agglutination
;
Agglutination Tests
;
Blood Grouping and Crossmatching*
;
Capillary Action
;
Hemagglutination
;
Immune Sera
;
Microfluidics*
;
Microtechnology
4.A Case of Antiphospholipid Antibody Syndrome Accompanied by Valvular Heart Disease and Moya Moya Syndrome.
Sung Ho CHOI ; Bo Young JOUNG ; Dongsoo KIM ; Jae Phil CHOI ; Min Ho CHO ; Sung Ju LEE ; Sang Hak LEE ; Byung Eun PARK ; Bum Kee HONG ; Hyuck Moon KWON ; Chanil PARK ; Tae Sub CHUNG ; Hyun Seung KIM
Korean Circulation Journal 2003;33(7):620-624
A case of antiphospholipid antibody syndrome, accompanied by valvular heart disease and Moya moya syndrome, has never been reported. Here, we report on a case that had mitral regurgitation and Moya moya syndrome, associated with antiphospholipid antibody syndrome secondary to systemic lupus erythematosus. This patient underwent a mitral valve replacement for mitral valve regurgitation. The postoperative course was uneventful, and the pathological findings of the mitral valve showed a degenerative change, due to chronic inflammation, a proliferative fibrous change and calcification, but without thrombus formation. However, the patient returned to the hospital with a cerebral hemorrhage, which was caused by Moya moya syndrome. Surgical drainage was performed, and the patient was discharged without any complications. The patient is on anticoagulation and immunosuppression drugs, with no problems to date.
Antibodies, Antiphospholipid*
;
Antiphospholipid Syndrome*
;
Cerebral Hemorrhage
;
Drainage
;
Heart Valve Diseases*
;
Humans
;
Immunosuppression
;
Inflammation
;
Lupus Erythematosus, Systemic
;
Mitral Valve
;
Mitral Valve Insufficiency
;
Thrombosis
5.Clinical Applicability of Newly Developed Image-based Cell Counter for Counting CD34+ Cells: Comparison with Flow Cytometric Analysis
Wee Jin RAH ; Eun Kyung SHIN ; Hani KOH ; Jin Young SUH ; Misoo CHANG ; Eunwoo NAM ; Jong Hyun OH ; Yumi JUNG ; Ji Yeon LEE ; Sung Rok BONG ; Sung Hun HONG ; Jee Young KIM ; Sunmi HAN ; Jeoung Ku HWANG ; Chanil CHUNG ; Young Ho LEE
Clinical Pediatric Hematology-Oncology 2016;23(2):125-132
BACKGROUND: Flow cytometric analysis is the standard method for enumerating CD34+ stem cells in hematopoietic stem cell transplantation. However, it has some limitations such as expensive instrumentation, high reagent costs, and discrepancies between technicians and laboratories. We compared counts of total nucleated cells (TNCs) and CD34+ cells counts obtained from a flow cytometer with a newly-developed image-based microscopic cell counter (ADAM II) to evaluate the possibility of clinical application of the ADAM II.METHODS: We used 18 samples of circulating peripheral blood (PB) and waste tube fractions of peripheral blood stem cells (PBSCs) harvested by apheresis after G-CSF mobilization from adult volunteer donors. We assessed the reproducibility and linearity of the new procedure and compared the numbers of TNCs and viable CD34+ cells determined with the ADAM II and two different flow cytometers (FACSCalibur, FACSCanto II).RESULTS: Numbers of viable CD34+ cells determined with the ADAM II were accurate over the expected range; the intra-assay coefficient of variation was ≤19.8%. Linearity was also satisfactory (R²=0.99). TNC counts obtained with the ADAM II were highly correlated with those obtained with the FACSCalibur (R²>0.9841, P<0.0001) and FACSCanto II (R²>0.9620, P<0.0001), as were the numbers of viable CD34+ cells obtained with the ADAM II and the FACSCalibur and FACSCanto II (R²>0.9911, P<0.0001 and R²>0.9791, P<0.0001), respectively.CONCLUSION: The newly developed image-based microscopic cell counter (ADAM II) appears to be suitable for enumerating TNCs and viable CD34+ cells.
Adult
;
Blood Component Removal
;
Cell Count
;
Granulocyte Colony-Stimulating Factor
;
Hematopoietic Stem Cell Transplantation
;
Humans
;
Methods
;
Stem Cells
;
Tissue Donors
;
Volunteers
6.Enumeration of CD34-positive Stem Cells Using the ADAMII Image-based Fluorescence Cell Counter
Haein YU ; Jaeeun YOO ; Jung Sil HWANG ; Mikyung KIM ; Kyung Hee BAE ; Dong Wook JEKARL ; Jong Hyun OH ; Ji Yeon LEE ; Sunmi HAN ; Chanil CHUNG ; Myungshin KIM ; Yonggoo KIM
Annals of Laboratory Medicine 2019;39(4):388-395
BACKGROUND: It is very important to accurately enumerate CD34-positive (CD34+) cells for successful hematopoietic stem cell transplantation (HSCT). We evaluated the ability of the newly developed image based-immunofluorescence cell counter ADAMII (NanoEntek, Seoul, Korea) to enumerate CD34+ cells, which was improved through simultaneous CD45 analysis. METHODS: We enumerated CD34+ cells with ADAMII using 19 peripheral blood (PB) and 91 leukapheresis samples from HSCT donors. Analytical performance, including precision and linearity, was analyzed, and sample stability during storage was evaluated. Viable CD34+ cell count (vCD34) and viable CD45+ cell count (vCD45) and the percentage of viable CD34+ cells among viable CD45+ cells (CD34/CD45) as measured by ADAMII were compared with the corresponding values from two flow cytometry assays, using regression analysis. RESULTS: ADAMII demonstrated acceptable precision, as CV values of vCD34 from six samples with different counts were all < 10% (range: 3.49–9.51%). CV values of the vCD45 and CD34/45 ranged from 4.03% to 9.67% and from 2.48% to 10.07%, respectively. The linearity of vCD34 showed an excellent R 2 value (0.99) when analyzed using the intended count and flow cytometry data. The ADAMII and two flow cytometry-based assays generated very similar data for the PB and leukapheresis samples. CONCLUSIONS: ADAMII demonstrated excellent performance for use as a routine clinical assay in terms of CD34+ cell enumeration from PB and leukapheresis samples. Moreover, it could be used as a point-of-care-test for determining mobilization time and predicting an adequate apheresis stem cell product.
Blood Component Removal
;
Cell Count
;
Flow Cytometry
;
Fluorescence
;
Hematopoietic Stem Cell Transplantation
;
Humans
;
Leukapheresis
;
Seoul
;
Stem Cells
;
Tissue Donors