1.Determination method of clopidogrel and its metabolites in rat plasma and its pharmacokinetic study
Huan YI ; Lan MIAO ; Changying REN ; Li LIN ; Mingqian SUN ; Qing PENG ; Ying ZHANG ; Jianxun LIU
China Pharmacy 2025;36(13):1599-1603
OBJECTIVE To establish a method for determining the contents of clopidogrel (CLP), clopidogrel carboxylate (CLP-C), clopidogrel acyl-β-D-glucuronide (CLP-G) and contents of clopidogrel active metabolite (CAM) in rat plasma, and to investigate their in vivo pharmacokinetic characteristics. METHODS The Shisedo CAPCELL ADME column was used with a mobile phase consisting of water and acetonitrile (both containing 0.1% formic acid) in a gradient elution. The flow rate was 0.4 mL/min, and the column temperature was maintained at 20 ℃. The injection volume was 2 μL. The analysis was performed in positive ion mode using electrospray ionization with multiple reaction monitoring. The ion pairs for quantitative analysis were m/z 322.1→211.9 (for CLP), m/z 308.1→197.9 (for CLP-C), m/z 322.1→154.8 (for CLP-G), m/z 504.1→154.9 [for racemic CAM derivative (CAMD)]. Six rats were administered a single intragastric dose of CLP (10 mg/kg). Blood samples were collected before medication and at 0.08, 0.33, 0.66, 1, 2, 4, 6, 10, 23 and 35 hours after medication. The established method was used to detect the serum contents of various components in rats. Pharmacokinetic parameters were then calculated using WinNonlin 6.1 software. RESULTS The linear ranges for CLP, CLP-C and CAMD were 0.08-20.00, 205.00-8 000.00, and 0.04-25.00 ng/mL, respectively (r≥0.990). The relative standard deviations for both intra-day and inter-day precision tests were all less than 15%, and the relative errors for accuracy ranged from -11.68% to 14.40%. The coefficients of variation for the matrix factors were all less than 15%, meeting the requirements for bioanalytical method validation. The results of the pharmacokinetic study revealed that, following a single intagastric administration of CLP in rats, the exposure to the parent CLP in plasma was extremely low. Both the area under the drug concentration-time curve (AUC0-35 h) and the peak concentration of the parent CLP were lower than those of its metabolites. The AUC0-35 h of the active metabolite CAM was approximately 43 times that of CLP, though it had a shorter half-life (2.53 h). The inactive metabolite CLP-C exhibited the highest exposure level, but it reached its peak concentration the latest and was eliminated slowly. The AUC0-35 h of CLP-G was about four times that of CAM, and its half-life was similar to that of CLP-C. CONCLUSIONS This study successfully established an liquid chromatography-tandem mass spectrometry method for the determination of CLP and its three metabolites, and revealed their pharmacokinetic characteristics in rats. Specifically, the parent drug CLP was rapidly eliminated, while the inactive metabolites CLP-C and CLP-G exhibited long half-lives, and active metabolite CAM displayed a transient exposure pattern.
2.Construction of mouse podocyte clone-5 cell lines with Smad3 knockout by CRISPR/Cas9.
Xiu YANG ; Jiangshan SHI ; Honglian WANG ; Li WANG ; Hongwei SU ; Chen CHEN ; Changying ZHAO
Chinese Journal of Biotechnology 2025;41(4):1658-1670
This study established the mouse podocyte clone-5 (MPC5) with Smad3 knockout and studied the effect of transforming growth factor-beta 1 (TGF-β1) on the dedifferentiation of the MPC5 cells with Smad3 knockout, aiming to provide a cell tool for studying the role of Smad3 in mouse podocytes. The single-guide RNA (sgRNA) sequence targeting Smad3 was designed according to the principles of CRISPR/Cas9 design. The pX458-Smad3 vector was constructed and introduced into competent cells, and then the vector was extracted and used to transfect MPC5 cells. The successfully transfected cells were sorted by a flow cytometer. After single-cell clone expansion, PCR amplification of sequences adjacent to the edition site of Smad3 and sequencing were performed to identify potential cells with gene knockout. Western blotting was employed to verify the knockout efficiency of Smad3. Finally, the effect of Smad3 knockout on TGF-β1-induced dedifferentiation of MPC5 cells was analyzed by reverse transcription-polymerase chain reacting (RT-PCR), Western blotting, and the immunofluorescence method. The sgRNA was designed to target the fifth exon of Smad3. EGFP expression was observed 24 h after transfection of the pX458-Smad3 plasmid into MPC5 cells, with the transfection efficiency of 0.1% as determined by flow cytometry. From the transfected cells, 21 cell clones were obtained through flow cytometric sorting and single-cell clone expansion. PCR amplification and sequencing of the region around the sgRNA target site in Smad3 identified two cell clones with biallelic frameshift mutations. Western blotting results confirmed the absence of Smad3 expression in these clones, indicating successful establishment of the MPC5 cell line with Smad3 knockout. In normal MPC5 cells, TGF-β1 stimulation promoted the expression of fibrosis-related genes fibronectin and Col1a1 (collagen I) and inhibited the expression of the podocyte marker proteins synaptopodin and podocin, which suggested epithelial-mesenchymal transition and podocyte injury. However, in the two MPC5 cell lines with Smad3 knockout, TGF-β1-induced expression of epithelial-mesenchymal transition markers was significantly suppressed. The MPC5 cell lines with Smad3 knockout that were constructed by CRISPR/Cas9 provide a valuable cell model for functional studies of Smad3 protein and highlight the critical role of Smad3 in cell dedifferentiation.
Animals
;
Smad3 Protein/genetics*
;
CRISPR-Cas Systems/genetics*
;
Mice
;
Podocytes/metabolism*
;
Transforming Growth Factor beta1/pharmacology*
;
Cell Line
;
Gene Knockout Techniques
;
RNA, Guide, CRISPR-Cas Systems/genetics*
3.Effect of preoperative oral ibuprofen on postoperative pain after dental implantation: a randomized controlled trial
Kang GAO ; Xuezhu WEI ; Bin ZHAO ; Zhiguang LIU ; Conglin DU ; Xin WANG ; Yao WANG ; Changying LIU ; Dezheng TANG ; Qi ZHANG ; Ruiqing WU ; Mingming OU ; Wei LI ; Qian CHENG ; Yilin XIE ; Pan MA ; Jun LI ; Hao WANG ; Zuomin WANG ; Su CHEN ; Wei ZHANG ; Jian ZHOU
Chinese Journal of Stomatology 2024;59(8):777-783
Objective:To evaluate the effect of preemptive analgesia with ibuprofen on postoperative pain following single posterior tooth implantation, aiming to provide a clinical reference for its application.Methods:A multicenter, randomized, double-blind, placebo-controlled parallel-group trial was conducted. A total of 82 participants were included in the trial, meeting the eligibility criteria from April 2022 to April 2024 at the Capital Medical University School of Stomatology (40 cases), Beijing TianTan Hospital, Capital Medical University (22 cases), Beijing Chao-Yang Hospital, Capital Medical University (20 cases). Participants were randomly assigned in a 1∶1 ratio to either the ibuprofen group or the control group, with each group comprising 41 individuals. Participants in the ibuprofen group received 300 mg of sustained-release ibuprofen capsules orally 15 min before surgery, while the control group received a placebo. Both groups received the same postoperative analgesic regimen for 3 days. Pain scores were assessed using the numerical rating scale at 30 min, 4 h, 6 h, 8 h, 24 h, 48 h, and 72 h postoperatively, and the additional use of analgesic medication was recorded from days 4 to 6 postoperatively.Results:A total of 82 participants were initially enrolled in the study, with 7 dropouts (4 from the control group and 3 from the ibuprofen group), resulting in 75 participants (37 in the control group and 38 in the ibuprofen group) completing the trial. There were no reports of adverse events such as nausea or vomiting among the participants. The ibuprofen group exhibited significantly lower pain scores at 4 h, 6 h and 8 h [1.0 (0.0, 2.0), 1.0 (0.0, 2.0), 1.5 (0.0, 3.0) ] postoperatively compared to the control group 4 h, 6 h and 8 h [2.0 (1.0, 3.0), 3.0 (1.5, 4.0), 2.0 (1.0, 4.0)] ( Z=-1.99, P=0.047; Z=-3.01, P=0.003; Z=-2.10, P=0.036). The proportions of patients requiring additional analgesic medication between days 4 and 6 post-surgery were 18.4% (7/38) in the ibuprofen group and 27.0% (10/37) in the control group, with no significant difference (χ 2=0.79, P=0.373). The median additional medication usage postoperatively was [0.0 (0.0, 0.0) pills] in the ibuprofen group and [0.0 (0.0, 1.0) pills] in the control group, with no significant difference ( Z=-0.78, P=0.439). Conclusions:Preemptive analgesia with ibuprofen effectively reduces postoperative pain following tooth implantation, representing a safe and effective perioperative pain management strategy.
4.Correlation between preoperative coronary angiography and postoperative acute kidney injury in cardiac surgery: A retrospective study in a single center
Changying ZHAO ; Yang YAN ; Tao SHI ; Yongxin LI ; Jing LI ; Wenyan LIU ; Miaomiao LIU ; Xinglong ZHENG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(12):1820-1825
Objective To explore the relationship between preoperative coronary angiography and postoperative acute kidney injury (AKI) in cardiac surgery. Methods The clinical data of patients who underwent coronary angiography within 30 days before cardiac surgery in the First Affiliated Hospital of Xi’an Jiaotong University from January 2015 to April 2019 were retrospectively analyzed. Univariate analysis and multivariate logistic regression analyses were used to explore the relationship between the interval from preoperative coronary angiography to cardiac surgery and postoperative AKI. Results Finally 1 112 patients were collected, including 700 males and 412 females, with a median age of 61 (55, 66) years. The incidence of postoperative AKI was 40.8% (454/1 112), of which grade 2-3 AKI accounted for 11.9%. Multivariate analysis showed that age (OR=1.049, 95%CI 1.022-1.077, P<0.001), body mass index (OR=1.065, 95%CI 1.010-1.123, P=0.020) and time interval between preoperative coronary angiography and cardiac surgery within 24 hours (OR=1.625, 95%CI 1.116-2.364, P=0.011) were independent predictors of postoperative AKI. Patients who underwent coronary angiography within 24 hours before surgery had a 10.6% higher incidence of postoperative AKI compared to those who underwent angiography ≥24 hours before surgery (P=0.004). Patients who underwent valve surgery with or without coronary artery bypass grafting (CABG) had a higher risk of AKI than those who only underwent CABG. The in-hospital stay of patients who developed AKI was 2 days longer than those without AKI. However, undergoing coronary angiography within 24 hours before cardiac surgery did not prolong the length of ICU stay or hospital stay, nor did it increase the risk of death or renal failure after the operation. Conclusion Undergoing coronary angiography within 24 hours before cardiac surgery increases the risk of postoperative AKI.
5.Research on the Construction of Standardized Evaluation System for Medical Faults Based on Delphi Method
Xiaogang WANG ; Longyao RAN ; Changying LIU ; Yongsheng WANG ; Tao CHEN ; Rui HE ; Shuzhi XIA ; Li LIU ; Xue XIE
Chinese Hospital Management 2024;44(10):81-86
Objective Establish a standardized evaluation system for medical faults,and provide theoretical basis for medical institutions and related industries to evaluate the illegality of medical behaviors.Methods Based on a litera-ture review,the medical fault assessment system was initially constructed,and then a research group was estab-lished to use Delphi method to invite 31 experts to evaluate the importance and feasibility of each article of the medi-cal fault assessment system and put forward suggestions for modification.Results The effective recovery rates of the two rounds of expert consultation were 83.9%and 96.8%,the expert authority coefficient was 0.902 and 0.887,and the Kendall's W test of all levels differences were statistically significant(P<0.001).The medical fault assess-ment system finally constructed includes 5 first-level items including practicing medicine according to law,informed notification,diagnosis and treatment technology,medical record documents and hospital management,as well as 10 second-level items,20 third-level items and 47 fourth-level items.The mean values of importance and feasibili-ty scores of all articles were greater than 4,standard deviations were less than 1,and coefficients of variation were less than 0.2.Conclusion The medical fault standardized evaluation system is scientific,reliable,innovative and appli-cable.
6.Research on the Construction of Standardized Evaluation System for Medical Faults Based on Delphi Method
Xiaogang WANG ; Longyao RAN ; Changying LIU ; Yongsheng WANG ; Tao CHEN ; Rui HE ; Shuzhi XIA ; Li LIU ; Xue XIE
Chinese Hospital Management 2024;44(10):81-86
Objective Establish a standardized evaluation system for medical faults,and provide theoretical basis for medical institutions and related industries to evaluate the illegality of medical behaviors.Methods Based on a litera-ture review,the medical fault assessment system was initially constructed,and then a research group was estab-lished to use Delphi method to invite 31 experts to evaluate the importance and feasibility of each article of the medi-cal fault assessment system and put forward suggestions for modification.Results The effective recovery rates of the two rounds of expert consultation were 83.9%and 96.8%,the expert authority coefficient was 0.902 and 0.887,and the Kendall's W test of all levels differences were statistically significant(P<0.001).The medical fault assess-ment system finally constructed includes 5 first-level items including practicing medicine according to law,informed notification,diagnosis and treatment technology,medical record documents and hospital management,as well as 10 second-level items,20 third-level items and 47 fourth-level items.The mean values of importance and feasibili-ty scores of all articles were greater than 4,standard deviations were less than 1,and coefficients of variation were less than 0.2.Conclusion The medical fault standardized evaluation system is scientific,reliable,innovative and appli-cable.
7.Research on the Construction of Standardized Evaluation System for Medical Faults Based on Delphi Method
Xiaogang WANG ; Longyao RAN ; Changying LIU ; Yongsheng WANG ; Tao CHEN ; Rui HE ; Shuzhi XIA ; Li LIU ; Xue XIE
Chinese Hospital Management 2024;44(10):81-86
Objective Establish a standardized evaluation system for medical faults,and provide theoretical basis for medical institutions and related industries to evaluate the illegality of medical behaviors.Methods Based on a litera-ture review,the medical fault assessment system was initially constructed,and then a research group was estab-lished to use Delphi method to invite 31 experts to evaluate the importance and feasibility of each article of the medi-cal fault assessment system and put forward suggestions for modification.Results The effective recovery rates of the two rounds of expert consultation were 83.9%and 96.8%,the expert authority coefficient was 0.902 and 0.887,and the Kendall's W test of all levels differences were statistically significant(P<0.001).The medical fault assess-ment system finally constructed includes 5 first-level items including practicing medicine according to law,informed notification,diagnosis and treatment technology,medical record documents and hospital management,as well as 10 second-level items,20 third-level items and 47 fourth-level items.The mean values of importance and feasibili-ty scores of all articles were greater than 4,standard deviations were less than 1,and coefficients of variation were less than 0.2.Conclusion The medical fault standardized evaluation system is scientific,reliable,innovative and appli-cable.
8.Research on the Construction of Standardized Evaluation System for Medical Faults Based on Delphi Method
Xiaogang WANG ; Longyao RAN ; Changying LIU ; Yongsheng WANG ; Tao CHEN ; Rui HE ; Shuzhi XIA ; Li LIU ; Xue XIE
Chinese Hospital Management 2024;44(10):81-86
Objective Establish a standardized evaluation system for medical faults,and provide theoretical basis for medical institutions and related industries to evaluate the illegality of medical behaviors.Methods Based on a litera-ture review,the medical fault assessment system was initially constructed,and then a research group was estab-lished to use Delphi method to invite 31 experts to evaluate the importance and feasibility of each article of the medi-cal fault assessment system and put forward suggestions for modification.Results The effective recovery rates of the two rounds of expert consultation were 83.9%and 96.8%,the expert authority coefficient was 0.902 and 0.887,and the Kendall's W test of all levels differences were statistically significant(P<0.001).The medical fault assess-ment system finally constructed includes 5 first-level items including practicing medicine according to law,informed notification,diagnosis and treatment technology,medical record documents and hospital management,as well as 10 second-level items,20 third-level items and 47 fourth-level items.The mean values of importance and feasibili-ty scores of all articles were greater than 4,standard deviations were less than 1,and coefficients of variation were less than 0.2.Conclusion The medical fault standardized evaluation system is scientific,reliable,innovative and appli-cable.
9.Research on the Construction of Standardized Evaluation System for Medical Faults Based on Delphi Method
Xiaogang WANG ; Longyao RAN ; Changying LIU ; Yongsheng WANG ; Tao CHEN ; Rui HE ; Shuzhi XIA ; Li LIU ; Xue XIE
Chinese Hospital Management 2024;44(10):81-86
Objective Establish a standardized evaluation system for medical faults,and provide theoretical basis for medical institutions and related industries to evaluate the illegality of medical behaviors.Methods Based on a litera-ture review,the medical fault assessment system was initially constructed,and then a research group was estab-lished to use Delphi method to invite 31 experts to evaluate the importance and feasibility of each article of the medi-cal fault assessment system and put forward suggestions for modification.Results The effective recovery rates of the two rounds of expert consultation were 83.9%and 96.8%,the expert authority coefficient was 0.902 and 0.887,and the Kendall's W test of all levels differences were statistically significant(P<0.001).The medical fault assess-ment system finally constructed includes 5 first-level items including practicing medicine according to law,informed notification,diagnosis and treatment technology,medical record documents and hospital management,as well as 10 second-level items,20 third-level items and 47 fourth-level items.The mean values of importance and feasibili-ty scores of all articles were greater than 4,standard deviations were less than 1,and coefficients of variation were less than 0.2.Conclusion The medical fault standardized evaluation system is scientific,reliable,innovative and appli-cable.
10.Research on the Construction of Standardized Evaluation System for Medical Faults Based on Delphi Method
Xiaogang WANG ; Longyao RAN ; Changying LIU ; Yongsheng WANG ; Tao CHEN ; Rui HE ; Shuzhi XIA ; Li LIU ; Xue XIE
Chinese Hospital Management 2024;44(10):81-86
Objective Establish a standardized evaluation system for medical faults,and provide theoretical basis for medical institutions and related industries to evaluate the illegality of medical behaviors.Methods Based on a litera-ture review,the medical fault assessment system was initially constructed,and then a research group was estab-lished to use Delphi method to invite 31 experts to evaluate the importance and feasibility of each article of the medi-cal fault assessment system and put forward suggestions for modification.Results The effective recovery rates of the two rounds of expert consultation were 83.9%and 96.8%,the expert authority coefficient was 0.902 and 0.887,and the Kendall's W test of all levels differences were statistically significant(P<0.001).The medical fault assess-ment system finally constructed includes 5 first-level items including practicing medicine according to law,informed notification,diagnosis and treatment technology,medical record documents and hospital management,as well as 10 second-level items,20 third-level items and 47 fourth-level items.The mean values of importance and feasibili-ty scores of all articles were greater than 4,standard deviations were less than 1,and coefficients of variation were less than 0.2.Conclusion The medical fault standardized evaluation system is scientific,reliable,innovative and appli-cable.

Result Analysis
Print
Save
E-mail